Pediatric Fracture Diagnosis - Ultra-Low-Dose CT with an Effective Dose Equal to that of Radiographs

被引:6
作者
Moritz, J. D. [1 ]
Hoffmann, B. [2 ]
Sehr, D. H.
Eggerking, J. [2 ]
Keil, K. [2 ]
Caliebe, A. [3 ]
Dischinger, J. [4 ]
Heller, M. [2 ]
Bolte, H. [5 ]
机构
[1] Univ Klinikum Schleswig Holstein, Klin Diagnost Radiol Padiat Radiol & Sonog, Lubeck, Germany
[2] Univ Klinikum Schleswig Holstein, Klin Diagnost Radiol, Lubeck, Germany
[3] Univ Klinikum Schleswig Holstein, Inst Med Informat & Stat, Lubeck, Germany
[4] Univ Kiel, N Deutsch Seminar Strahlenschutz, D-24098 Kiel, Germany
[5] UK Munster, Nukl Med Klin & Poliklin, Munster, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2012年 / 184卷 / 11期
关键词
extremities; CT; children; injuries; experimental study; infants; trauma; MULTIDETECTOR CT; X-RAY; RADIATION-EXPOSURE; CANCER-RISKS; COMPUTED-TOMOGRAPHY; CHILDREN; REDUCTION; RADIOLOGY; TRAUMA;
D O I
10.1055/s-0032-1313060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Computed tomography (CT) plays an important role in trauma diagnosis in children, especially for complex fractures. The aim of this study was to examine the diagnostic value of ultra-low-dose-CT (ULD-CT) with an effective dose equal to that of radiographs in an experimental study and to compare its results with those of radiographs. Materials and Methods: Limb bones of dead young pigs served as a model for pediatric bones. A total of 51 fractured and non-fractured bones were examined with a 64 multislice-CT with a standard dose protocol as gold standard, with two ultra-low-dose-protocols, and with standard radiographs with different exposures. Results: In spite of high background noise the examinations of ULD-CT were not adequate only in 2 of 204 cases. ULD-CT was slightly superior to radiographs in detection of fractures. ULD-CT could significantly better characterize the fractures than radiographs. The overall result of ULD-CT was significantly better than that of radiographs with standard exposure. Conclusion: ULD-CT with the effective dose of radiographs is successfully applicable in pediatric fracture diagnosis, and its overall result is significantly better than that of radiographs.
引用
收藏
页码:1026 / 1033
页数:8
相关论文
共 33 条
[11]   Cancer risks from diagnostic radiology [J].
Hall, E. J. ;
Brenner, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965) :362-378
[12]   Lessons we have learned from our children: cancer risks from diagnostic radiology [J].
Hall, EJ .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :700-706
[13]   Cancer Incidence Rate after Diagnostic X-Ray Exposure in 1976-2003 among Patients of a University Children's Hospital [J].
Hammer, G. P. ;
Seidenbusch, M. C. ;
Schneider, K. ;
Regulla, D. ;
Zeeb, H. ;
Spix, C. ;
Blettner, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (05) :404-414
[14]   Computer-Aided Pulmonary Nodule Detection - Performance of Two CAD Systems at Different CT Dose Levels [J].
Hein, P. A. ;
Rogalla, P. ;
Klessen, C. ;
Lembcke, A. ;
Romano, V. C. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (11) :1056-1064
[15]   Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography [J].
Horger, M ;
Claussen, CD ;
Bross-Bach, U ;
Vonthein, R ;
Trabold, T ;
Heuschmid, M ;
Pfannenberg, C .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (02) :289-297
[16]   A PC program for estimating organ dose and effective dose values in computed tomography [J].
Kalender, WA ;
Schmidt, B ;
Zankl, M ;
Schmidt, M .
EUROPEAN RADIOLOGY, 1999, 9 (03) :555-562
[17]   Detection of simulated inflicted metaphyseal fractures in a fetal pig model: Image optimization and dose reduction with computed radiography [J].
Kleinman, Patricia L. ;
Zurakowski, David ;
Strauss, Keith J. ;
Cleveland, Robert H. ;
Perez-Rosello, Jeannette M. ;
Nichols, David P. ;
Zou, Kelly H. ;
Kleinman, Paul K. .
RADIOLOGY, 2008, 247 (02) :381-390
[18]   Does ultra-low-dose CT with a radiation dose equivalent to that of KUB suffice to detect renal and ureteral calculi? [J].
Kluner, C ;
Hein, PA ;
Gralla, O ;
Hein, E ;
Hamm, B ;
Romano, V ;
Rogalla, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (01) :44-50
[19]   Noise Reduction and Image Quality Improvement of Low Dose and Ultra Low Dose Brain Perfusion CT by HYPR-LR Processing [J].
Krissak, Radko ;
Mistretta, Charles A. ;
Henzler, Thomas ;
Chatzikonstantinou, Anastasios ;
Scharf, Johann ;
Schoenberg, Stefan O. ;
Fink, Christian .
PLOS ONE, 2011, 6 (02)
[20]  
Little MP, 2009, RADIOLOGY, V251, P6, DOI [10.1148/radiol.2511081686, 10.1148/radiol.1.2511081686]