Effects of light scattering on optical-resolution photoacoustic microscopy

被引:67
作者
Liu, Yan [1 ]
Zhang, Chi [1 ]
Wang, Lihong V. [1 ]
机构
[1] Washington Univ, Dept Biomed Engn, Opt Imaging Lab, St Louis, MO 63130 USA
基金
美国国家卫生研究院;
关键词
photoacoustic microscopy; light scattering; optical focusing; imaging depth; Monte Carlo simulation; focused ultrasonic transducer; spatial impulse response; COHERENCE TOMOGRAPHY SYSTEMS; MONTE-CARLO-SIMULATION; IN-VIVO; TURBID MEDIA; TISSUE; SIGNAL; DEPTH; ATTENUATION; TRANSPORT;
D O I
10.1117/1.JBO.17.12.126014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The imaging depth of ballistic optical imaging technologies is limited by light scattering. To study the effects of scattering on optical-resolution photoacoustic microscopy (OR-PAM), the signals were divided into target and background signals. A method to simulate the point spread function (PSF) of the PAM system considering both optical illumination and acoustic detection was proposed, then the PSF was used to calculate the contribution of each class of signal at different depths of the focal plane (z(f)). How image contrast is degraded when there is a uniformly absorbing background as well as when there are small targets densely packed in the acoustic resolution cell were studied. By using the hyperboloid-focusing-based Monte Carlo method, optical focusing into a scattering medium was simulated. It was found that the lateral resolution provided by optical focusing is degraded by only 14% when z(f) = 1.1 transport mean free path (l'(t)), compared with the case of no scattering. When z(f) = 1.7 l'(t), the fluence at 50 mu m radial distance away from the focal point is 93% of that at the focal point, which shows optical focusing is very weak at this depth. The method to simulate the PSF of PAM can be used in the future to optimize parameters so as to improve the system performance. (c) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.12.126014]
引用
收藏
页数:9
相关论文
共 45 条
[1]   Next-generation acceleration and code optimization for light transport in turbid media using GPUs [J].
Alerstam, Erik ;
Lo, William Chun Yip ;
Han, Tianyi David ;
Rose, Jonathan ;
Andersson-Engels, Stefan ;
Lilge, Lothar .
BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02) :658-675
[2]   TRANSIENT FIELDS OF CONCAVE ANNULAR ARRAYS [J].
ARDITI, M ;
FOSTER, FS ;
HUNT, JW .
ULTRASONIC IMAGING, 1981, 3 (01) :37-61
[4]   Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues [J].
Durr, Nicholas J. ;
Weisspfennig, Christian T. ;
Holfeld, Benjamin A. ;
Ben-Yakar, Adela .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (02)
[5]   Effective point-spread function for fast image modeling and processing in microscopic imaging through turbid media [J].
Gan, XS ;
Gu, M .
OPTICS LETTERS, 1999, 24 (11) :741-743
[6]   Amplitude and Phase of Tightly Focused Laser Beams in Turbid Media [J].
Hayakawa, Carole K. ;
Venugopalan, Vasan ;
Krishnamachari, Vishnu V. ;
Potma, Eric O. .
PHYSICAL REVIEW LETTERS, 2009, 103 (04)
[7]  
Hecht E., 2016, Optics, V5
[8]   Time-reversed ultrasonically encoded optical focusing in biological tissue [J].
Lai, Puxiang ;
Xu, Xiao ;
Liu, Honglin ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (03)
[9]   Reflection-mode time-reversed ultrasonically encoded optical focusing into turbid media [J].
Lai, Puxiang ;
Xu, Xiao ;
Liu, Honglin ;
Suzuki, Yuta ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (08)
[10]   Effect of Light Scattering on Optical-Resolution Photoacoustic Microscopy [J].
Liu, Yan ;
Zhang, Chi ;
Hu, Song ;
Suzuki, Yuta ;
Xu, Zhun ;
Ferradal, Silvina ;
Wang, Lihong V. .
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223