Optimal shape of LCVA for vibration control of structures subjected to along wind excitation

被引:2
作者
Park, Ji-Hun [2 ]
Min, Kyung-Won [1 ]
机构
[1] Dankook Univ, Dept Architectural Engn, Yongin, South Korea
[2] Univ Incheon, Dept Architectural Engn, Inchon, South Korea
关键词
liquid column vibration absorber; vibration control; equivalent damping ratio; LIQUID COLUMN DAMPERS; RESPONSE CONTROL; TALL BUILDINGS; ABSORBERS LCVA; OPTIMIZATION; PERFORMANCE;
D O I
10.12989/sss.2012.10.6.573
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, a procedure to design an optimal LCVA that maximizes the equivalent damping ratio added to the primary structure subjected to along-wind excitation is proposed. That design procedure does not only consider the natural frequency and damping ratio of the LCVA, but also the proportion of the U-shaped liquid, which is closely related to the participation ratio of the liquid mass in inertial force. In addition, constraints to ensure the U-shape of the liquid are considered in the design process, so that suboptimal solutions that violate the optimal tuning law partly are adopted as a candidate of the optimal LCVA. The proposed design procedure of the LCVA is applied to the control of the 76-story benchmark building, and the optimal proportions of the liquid shape under various design conditions are compared.
引用
收藏
页码:573 / 591
页数:19
相关论文
共 25 条
[1]  
Agrawal AK, 1999, J INTEL MAT SYST STR, V10, P997, DOI 10.1106/YV3B-TP5H-HWQ2-X10K
[2]  
[Anonymous], 1999, Wind Struct, DOI [10.12989/was.1999.2.3.201, DOI 10.12989/WAS.1999.2.3.201]
[3]  
Chang CC, 1998, STRUCT DES TALL BUIL, V7, P147
[4]   Control performance of liquid column vibration absorbers [J].
Chang, CC ;
Hsu, CT .
ENGINEERING STRUCTURES, 1998, 20 (07) :580-586
[5]   Experimental and theoretical investigations of equivalent viscous damping of structures with TLCD for different fluids [J].
Colwell, Shane ;
Basu, Biswajit .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (01) :154-163
[6]  
Davenport A.G., 1964, P I CIVIL ENG
[8]   Characteristics of multiple tuned liquid column dampers in suppressing structural vibration [J].
Gao, H ;
Kwok, KSC ;
Samali, B .
ENGINEERING STRUCTURES, 1999, 21 (04) :316-331
[9]   Optimization of tuned liquid column dampers [J].
Gao, H ;
Kwok, KCS ;
Samali, B .
ENGINEERING STRUCTURES, 1997, 19 (06) :476-486
[10]   PERFORMANCE TEST OF A TUNED LIQUID MASS DAMPER FOR REDUCING BIDIRECTIONAL RESPONSES OF BUILDING STRUCTURES [J].
Heo, Jae-Sung ;
Lee, Sung-Kyung ;
Park, Eunchurn ;
Lee, Sang-Hyun ;
Min, Kyung-Won ;
Kim, Hongjin ;
Jo, Jiseong ;
Cho, Bong-Ho .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2009, 18 (07) :789-805