Testing an energy-dispersive counting-mode detector with hard x-rays from a synchrotron source

被引:12
作者
Baeumer, Christian [1 ]
Martens, Gerhard [2 ]
Menser, Bernd [1 ]
Roessl, Ewald [2 ]
Schlomka, Jens-Peter [2 ]
Steadman, Roger [1 ]
Zeitler, Guenter [1 ]
机构
[1] Philips Res Europe, D-52066 Aachen, Germany
[2] Philips Res Europe, D-22335 Hamburg, Germany
关键词
coincidence; photon counting; pulse pile-up; synchrotron; x-ray detector; x-ray imaging;
D O I
10.1109/TNS.2008.924083
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A counting-mode line detector has been evaluated at a synchrotron radiation source in order to assess its performance for imaging applications. The x-ray detector is based on 3 mm thick CdZnTe arrays with 1 mm pixel pitch and multi-threshold counting electronics. Data readout has been performed in threshold scan mode to provide maximum energy dispersion. The acquired energy spectra are interpreted regarding the characteristics of a periodic source and pulse pile-up in the detector. In particular, energy response and rate behavior of single-photon and double-photon events are investigated. Count rate dynamics are studied up to incident rates of 2 x 10(6) photons/pixel/s. A further subject of the investigation is the variance of the observed counting rate. Linearity in the energy domain is tested between 40 keV and 140 keV.
引用
收藏
页码:1785 / 1790
页数:6
相关论文
共 23 条
  • [1] ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY
    ALVAREZ, RE
    MACOVSKI, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) : 733 - 744
  • [2] The effect of beam time structure on counting detectors in SRS experiments
    Bateman, JE
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 : 307 - 312
  • [3] Performance of an energy resolving X-ray pixel detector
    Bates, R
    Derbyshire, G
    Gannon, WJF
    Iles, G
    Lowe, B
    Mathieson, K
    Passmore, MS
    Prydderch, M
    Seller, P
    Smith, K
    Thomas, SL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) : 161 - 165
  • [4] A pixel detector with large dynamic range for high photon counting rates
    Bérar, JF
    Blanquart, L
    Boudet, N
    Breugnon, P
    Caillot, B
    Clemens, JC
    Delpierre, P
    Koudobine, I
    Mouget, C
    Potheau, R
    Valin, I
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2002, 35 : 471 - 476
  • [5] High-rate counters versus integrating devices in synchrotron experiments
    Bordessoule, M
    Lemonnier, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 481 (1-3) : 592 - 600
  • [6] BRINKER F, COMMUNICATION
  • [7] A pixel detector for the protein crystallography beamline at the SLS
    Brönnimann, C
    Baur, R
    Eikenberry, EF
    Fischer, P
    Florin, S
    Horisberger, R
    Lindner, M
    Schmitt, B
    Schulze, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) : 531 - 535
  • [8] Detective quantum efficiency dependence on x-ray energy weighting in mammography
    Cahn, RN
    Cederström, B
    Danielsson, M
    Hall, A
    Lundqvist, M
    Nygren, D
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2680 - 2683
  • [9] Cajipe VB, 2004, IEEE NUCL SCI CONF R, P4548
  • [10] PILE-UP PHENOMENA IN SOLID-STATE DETECTION EFFECTS DUE TO SYNCHROTRON SOURCES
    COUSINS, CSG
    GERWARD, L
    LAUNDY, D
    MEADS, RE
    OLSEN, JS
    SHELDON, BJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (03) : 598 - 608