Mixed-mode toughness of human cortical bone containing a longitudinal crack in far-field compression

被引:22
作者
Olvera, Diana [2 ]
Zimmermann, Elizabeth A. [1 ,2 ]
Ritchie, Robert O. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
Human cortical bone; Toughness; Mixed-mode loading; FRACTURE-TOUGHNESS; CEMENT LINE; SPECIMEN; INTERFACES; RESISTANCE; OSTEONS; GROWTH;
D O I
10.1016/j.bone.2011.11.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone is generally loaded under multiaxial conditions in vivo: as it invariably contains microcracks, this leads to complex mixed-mode stress-states involving combinations of tension, compression and shear. In previous work on the mixed-mode loading of human cortical bone (using an asymmetric bend test geometry), we found that the bone toughness was lower when loaded in far-field shear than in tension (opposite to the trend in most brittle materials), although only for the transverse orientation. This is a consequence of the competition between preferred mechanical vs. microstructural crack-path directions, the former dictated by the direction of the maximum mechanical "driving force" (which changes with the mode-rnixity), and the latter by the "weakest" microstructural path (which in human bone is along the osteonal interfaces or cement lines). As most microcracks are oriented longitudinally, we investigate here the corresponding mixed-mode toughness of human cortical bone in the longitudinal (proximal-distal) orientation using a "double cleavage drilled compression" test geometry, which provides a physiologically-relevant loading condition for bone in that it characterizes the toughness of a longitudinal crack loaded in far-field compression. In contrast to the transverse toughness, results show that the longitudinal toughness, measured using the strain-energy release rate, is significantly higher in shear (mode II) than in tension (model). This is consistent, however, with the individual criteria of preferred mechanical vs. microstructural crack paths being commensurate in this orientation. Published by Elsevier Inc.
引用
收藏
页码:331 / 336
页数:6
相关论文
共 25 条
  • [1] [Anonymous], 2002, Bones: Structure and Mechanics
  • [2] ATKINSON C, 1982, INT J FRACTURE, V18, P279
  • [3] In vivo measurement of human tibial strains during vigorous activity
    Burr, DB
    Milgrom, C
    Fyhrie, D
    Forwood, M
    Nyska, M
    Finestone, A
    Hoshaw, S
    Saiag, E
    Simkin, A
    [J]. BONE, 1996, 18 (05) : 405 - 410
  • [4] COMPOSITION OF THE CEMENT LINE AND ITS POSSIBLE MECHANICAL ROLE AS A LOCAL INTERFACE INHUMAN COMPACT-BONE
    BURR, DB
    SCHAFFLER, MB
    FREDERICKSON, RG
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (11) : 939 - &
  • [5] ANISOTROPIC ANALYSIS OF STRAIN ROSETTE INFORMATION FROM CORTICAL BONE
    CARTER, DR
    [J]. JOURNAL OF BIOMECHANICS, 1978, 11 (04) : 199 - 202
  • [6] DEVELOPMENT OF A TEST METHOD FOR MEASURING THE MIXED-MODE FRACTURE-RESISTANCE OF BIMATERIAL INTERFACES
    CHARALAMBIDES, PG
    CAO, HC
    LUND, J
    EVANS, AG
    [J]. MECHANICS OF MATERIALS, 1990, 8 (04) : 269 - 283
  • [7] Orientation and loading condition dependence of fracture toughness in cortical bone
    Feng, ZD
    Rho, J
    Han, S
    Ziv, I
    [J]. MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2000, 11 (01): : 41 - 46
  • [8] Asymmetric four-point crack specimen
    He, MY
    Hutchinson, JW
    [J]. JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2000, 67 (01): : 207 - 209
  • [9] ANALYSIS OF THE DOUBLE CLEAVAGE DRILLED COMPRESSION SPECIMEN FOR INTERFACE FRACTURE ENERGY MEASUREMENTS OVER A RANGE OF MODE MIXITIES
    HE, MY
    TURNER, MR
    EVANS, AG
    [J]. ACTA METALLURGICA ET MATERIALIA, 1995, 43 (09): : 3453 - 3458
  • [10] Irwin GR., 1957, J Appl Mech, V24, P361, DOI [10.1115/1.4011547, DOI 10.1115/1.4011547]