Sixteen-slice multidetector computed tomography pulmonary angiography -: Evaluation of cardiogenic motion artifacts and influence of rotation time on image quality

被引:8
作者
Bruzzi, JF
Rémy-Jardin, M
Kirsch, J
Hennion, D
Deken-Delanoy, V
Duhamel, A
Rémy, J
机构
[1] Hosp Calmette, Dept Thorac Imaging, F-59037 Lille, France
[2] Clin Notre Dame, Dept Radiol, Tournai, Belgium
[3] CHRU Oscar Lambret, Dept Biomed Stat, Lille, France
关键词
computed tomography angiography; computed tomography technique; multislice computed tomography; pulmonary arteries; lung;
D O I
10.1097/01.rct.0000174029.14223.75
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To describe the site and severity of cardiogenic motion artifacts on 16-slice multidetector computed tomography (CT) angiograms of the pulmonary circulation and to determine the impact of the gantry rotation time on image quality. Methods: Sixty-nine patients undervent nonelectrocardiographically gated 16-slice multidetector CT angiography of the pulmonary circulation with a rotation time of 0.5 second (group 1, n = 37) or 0.375 second (group 2, n = 32). All scans were prospectively analyzed for the presence of cardiogenic motion artifacts in the pulmonary arteries, defined as a blurring of the edges of the pulmonary arteries on lung window settings with or without an artifactual loss of enhancement in the arterial lumen oil soft tissue windows ("pseudofilling defect"). In addition, the severity of pulmonary arterial blurring, was recorded using a 4-point scale. Results: Fifty-six patients (81%) had at least I pulmonary artery affected by cardiogenic motion artifacts. At the level of the central pulmonary arteries, movement artifacts responsible for a blurring of the arterial wall were present in 35 patients (51%), mainly observed at the level of the pulmonary trunk (n = 28, 41% of patients) and right main pulmonary artery (n = 23, 33% of patients); in 2 patients, motion artifact was responsible for a pseudoflap appearance within the arterial lumen (n = 14% of patients). Motion artifacts at the level of lobar pulmonary arteries were noted only in the lower divisions of the lingula (n = 1: 1.5% of patients) and in the left lower lobe (n = 2, 3% of patients). At the level of the segmental pulmonary arteries, motion artifacts were most frequently found in the lower divisions of the left upper lobe (lingula) (n = 19, 27.5% of patients) and left lower lobe (n = 29: 42% of patients). At the subsegmental level, motion artifacts were most common in the lower divisions of the left upper lobe (lingula) (n = 30: 43.5% of patients) and left lower lobe (n = 35, 51% of patients). Pseudofilling defects were depicted at the segmental and subsegmental levels in 28 patients (41% of the study group), almost exclusively located in the lingula and left lower lobe. Cardiogenic motion artifacts were observed with a significantly lower frequency in group 2 (22 of 32 patients, 69%) than in group 1 (34 of 37 patients, 92%) (P = 0.0142), with a concurrent reduction in the frequency of pseudofilling defects identified in 20 patients (54%) in group 1 and in 8 patients (25%) in group 2 (1) = 0.0142). Conclusion: The use of a 0.375-second rotation time enables significant reduction in the frequency of cardiogenic motion artifacts on 16-slice multidetector CT angiograms of the pulmonary circulation.
引用
收藏
页码:805 / 814
页数:10
相关论文
共 35 条
  • [1] Lung at thin-section CT: Influence of multiple-segment reconstruction on image quality
    Arac, M
    Oner, AY
    Celik, H
    Akpek, S
    Isik, S
    [J]. RADIOLOGY, 2003, 229 (01) : 195 - 199
  • [2] Chronic thromboembolism: Diagnosis with helical CT and MR imaging with angiographic and surgical correlation
    Bergin, CJ
    Sirlin, CB
    Hauschildt, JP
    Huynh, TV
    Auger, WR
    Fedullo, PF
    Kapelanski, DP
    [J]. RADIOLOGY, 1997, 204 (03) : 695 - 702
  • [3] Identifying the cause of unilateral hypoperfusion in patients suspected to have chronic pulmonary thromboembolism: Diagnostic accuracy of helical CT and conventional angiography
    Bergin, CJ
    Hauschildt, JP
    Brown, MA
    Channick, RN
    Fedullo, PF
    [J]. RADIOLOGY, 1999, 213 (03) : 743 - 749
  • [4] Thin-section CT of the lung: Does electrocardiographic triggering influence diagnosis?
    Boehm, T
    Willmann, JK
    Hilfiker, PR
    Weishaupt, D
    Seifert, B
    Crook, DW
    Marincek, B
    Wildermuth, S
    [J]. RADIOLOGY, 2003, 229 (02) : 483 - 491
  • [5] Campbell IA, 2003, THORAX, V58, P470
  • [6] Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction
    Coche, E
    Pawlak, S
    Dechambre, S
    Maldague, B
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (04) : 815 - 822
  • [7] A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage
    Flohr, T
    Prokop, M
    Becker, C
    Schoepf, UJ
    Kopp, AF
    White, RD
    Schaller, S
    Ohnesorge, B
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (06) : 1497 - 1503
  • [8] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [9] Peripheral pulmonary arteries: How far in the lung does multi-detector row spiral CT allow analysis?
    Ghaye, B
    Szapiro, D
    Mastora, I
    Delannoy, V
    Duhamel, A
    Remy, J
    Remy-Jardin, M
    [J]. RADIOLOGY, 2001, 219 (03) : 629 - 636
  • [10] EVALUATION OF ULTRAFAST CT SCANNING OF THE ADULT ABDOMEN
    GOLDBERG, HI
    GOULD, RG
    FEUERSTEIN, IM
    SIGETI, JS
    LIPTON, MJ
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (07) : 537 - 543