Assessment of the kinematic variability among 12 motion analysis laboratories

被引:177
作者
Gorton, George E., III [1 ]
Hebert, David A. [1 ]
Gannotti, Mary E. [1 ,2 ]
机构
[1] Shriners Hosp Children, Springfield, MA 01104 USA
[2] Univ Hartford, Phys Therapy Dept, Hartford, CT 06117 USA
关键词
Gait; Motion analysis; Kinematic; Repeatability; GONIOMETRIC MEASUREMENTS; CEREBRAL-PALSY; GAIT ANALYSIS; RELIABILITY; KNEE; REPEATABILITY; VALIDITY; SYSTEM; RANGE;
D O I
10.1016/j.gaitpost.2008.10.060
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Variability of kinematic measurements among sites participating in a collaborative research investigation is a primary factor in determining number of subjects, level of detectable difference and statistical power of a multi-site research study. In this study, one subject was evaluated by 24 examiners at 12 motion analysis laboratories and the observed variability of nine kinematic parameters are reported. Following implementation of a standardized gait analysis protocol the same subject returned for another evaluation at each of the 12 laboratories. Additionally, system accuracy and variability of the subject within and between test days are included as factors that may affect between site variability. Marker placement among examiners is identified as the largest source of variability. A 20% decrease in variability was noted following implementation of the standardized protocol. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 25 条
[1]   Reliability of range-of-motion measurement in the elbow and forearm [J].
Armstrong, AD ;
MacDermid, JC ;
Chinchalkar, S ;
Stevens, RS ;
King, GJW .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) :573-580
[2]  
Brosseau L, 1997, Physiother Res Int, V2, P150
[3]  
Chambers C., 1996, GAIT POSTURE, V4, P167, DOI DOI 10.1016/0966-6362(96)80573-X
[4]   A minimum standardized gait analysis protocol: Development and implementation by the Shriners Motion Analysis Laboratory Network (SMALnet) [J].
Davis, RB ;
Davids, JR ;
Gorton, GE ;
Aiona, M ;
Scarborough, N ;
Oeffinger, D ;
Tylkowski, C ;
Bagley, A .
PEDIATRIC GAIT: A NEW MILLENNIUM IN CLINICAL CARE AND MOTION ANALYSIS TECHNOLOGY, 2000, :1-7
[5]  
EKSTRAND J, 1982, ARCH PHYS MED REHAB, V63, P171
[6]   RELIABILITY AND VALIDITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE [J].
GOGIA, PP ;
BRAATZ, JH ;
ROSE, SJ ;
NORTON, BJ .
PHYSICAL THERAPY, 1987, 67 (02) :192-195
[7]   Repeated measures of adult normal walking using a video tracking system [J].
Growney, E ;
Meglan, D ;
Johnson, M ;
Cahalan, T ;
An, KN .
GAIT & POSTURE, 1997, 6 (02) :147-162
[8]   Walking speed influences on gait cycle variability [J].
Jordan, Kimberlee ;
Challis, John H. ;
Newell, Karl M. .
GAIT & POSTURE, 2007, 26 (01) :128-134
[9]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[10]   Consistency of surface EMG patterns obtained during gait from three laboratories using standardised measurement technique [J].
Kleissen, RFM ;
Litjens, MCA ;
Baten, CTM ;
Harlaar, J ;
Hof, AL .
GAIT & POSTURE, 1997, 6 (03) :200-209