Structural integrity of intraocular lenses with eyelets in a model of transscleral fixation with the Gore-Tex suture

被引:7
作者
Pollmann, Andre S. [1 ]
Lewis, Darrell R. [1 ]
Gupta, R. Rishi [1 ]
机构
[1] Dalhousie Univ, Dept Ophthalmol & Visual Sci, Halifax, NS, Canada
关键词
SCLERAL FIXATION; CLINICAL-OUTCOMES; SINGLE-PIECE; CHAMBER; IMPLANTATION;
D O I
10.1097/j.jcrs.0000000000000129
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare fracture characteristics of intraocular lenses (IOLs) used in transscleral fixation with the Gore-Tex suture. Setting: Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada. Design: Experimental study. Methods: A model was designed to compare the eyelet fracture characteristics of enVista MX60 IOL (model available before June 2018), the enVista MX60E IOL (current model), the Akreos AO60 IOL, and the CZ70BD IOL. Tension was applied through the Gore-Tex suture and measured with a digital force gauge. Two suture configurations (radial and nonradial) were tested using the MX60E IOL. Results: A total of 25 trials were conducted. The mean eyelet fracture force was 1.666 newtons (N) for the MX60 IOL (range, 1.000-2.000), 1.000 N for the MX60E IOL (range, 1.000-1.000), 2.330 N for the AO60 IOL (range, 2.000-3.000), and 0.998 N for the CZ70BD IOL (range, 0.990-1.000). When compared with the MX60E IOL, a greater eyelet strength was observed with the MX60 (P = .024) and AO60 (P = .004) IOLs. Radial and nonradial suture configurations did not affect the MX60E eyelet fracture force. Conclusions: The enVista MX60E eyelet may be less resistant to Gore-Tex suture tear out compared with the MX60 and AO60 IOLs. Altering suture configuration did not affect enVista eyelet resistance to fracture. During off-label use in transscleral fixation, extra caution should be taken when handling IOLs and applying tension on sutures. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:617 / 621
页数:5
相关论文
共 26 条
  • [1] Secondary intraocular lens implantation: Complication rates, visual acuity, and refractive outcomes
    Brunin, Greg
    Sajjad, Ahmar
    Kim, Eric J.
    de Oca, Ildamaris Montes
    Weikert, Mitchell P.
    Wang, Li
    Koch, Douglas D.
    Al-Mohtaseb, Zaina
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (03) : 369 - 376
  • [2] Comparison of Outcomes of Primary Anterior Chamber Versus Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Cataract Surgeries
    Chan, Tommy C. Y.
    Lam, Jasmine K. M.
    Jhanji, Vishal
    Li, Emmy Y. M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (02) : 221 - 226
  • [3] Unilateral Triangular Eyelet Disruption of Scleral-Fixed enVista Lens
    Chen, Kuan-Jen
    Sun, Chi-Chin
    Sun, Ming-Hui
    [J]. OPHTHALMOLOGY RETINA, 2019, 3 (08): : 680 - 680
  • [4] Gupta RR., 2019, J VITREORETIN DIS, V3, P395, DOI [10.1177/2474126419857207, DOI 10.1177/2474126419857207]
  • [5] Scleral fixation without conjunctival dissection
    Hoffman, Richard S.
    Fine, I. Howard
    Packer, Mark
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1907 - 1912
  • [6] Kalevar A, RETIN CASES BRIEF RE
  • [7] PARS PLANA VITRECTOMY WITH ANTERIOR CHAMBER VERSUS GORE-TEX SUTURED POSTERIOR CHAMBER INTRAOCULAR LENS PLACEMENT Long-Term Outcomes
    Khan, M. Ali
    Gupta, Omesh P.
    Pendi, Kasim
    Chiang, Allen
    Vander, James
    Regillo, Carl D.
    Hsu, Jason
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (05): : 860 - 866
  • [8] COMBINED PARS PLANA VITRECTOMY AND SCLERAL FIXATION OF AN INTRAOCULAR LENS USING GORE-TEX SUTURE
    Khan, M. Ali
    Samara, Wasim A.
    Gerstenblith, Adam T.
    Chiang, Allen
    Mehta, Sonia
    Garg, Sunir J.
    Hsu, Jason
    Gupta, Omesh P.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (07): : 1377 - 1384
  • [9] Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile
    Khan, M. Ali
    Gupta, Omesh P.
    Smith, Ryan G.
    Ayres, Brandon D.
    Raber, Irving M.
    Bailey, Robert S.
    Hsu, Jason
    Spirn, Marc J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (05) : 638 - 643
  • [10] Scleral Fixation of Posterior Chamber Intraocular Lenses Using Gore-Tex Suture With Concurrent 23-Gauge Pars Plana Vitrectomy
    Khan, Mohammed A.
    Gerstenblith, Adam T.
    Dollin, Michael L.
    Gupta, Omesh P.
    Spirn, Marc J.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (07): : 1477 - 1480