New methods for the concentration of viruses from urban sewage using quantitative PCR

被引:93
作者
Calgua, Byron [1 ]
Rodriguez-Manzano, Jesus [1 ]
Hundesa, Ayalkibet [1 ]
Sunen, Esther [2 ]
Calvo, Miguel [3 ]
Bofill-Mas, Silvia [1 ]
Girones, Rosina [1 ]
机构
[1] Univ Barcelona, Fac Biol, Dept Microbiol, E-08028 Barcelona, Spain
[2] Univ Basque Country, Fac Pharm, Dept Immunol Microbiol & Parasitol, Vitoria 01006, Spain
[3] Univ Barcelona, Fac Biol, Dept Stat, E-08028 Barcelona, Spain
关键词
Sewage; Virus concentration method; Human adenovirus; JC polyomavirus; Norovirus; HEPATITIS-E VIRUS; WATER-QUALITY INDICATORS; RIO-DE-JANEIRO; WASTE-WATER; HUMAN POLYOMAVIRUSES; MOLECULAR-DETECTION; HUMAN ADENOVIRUSES; ENTERIC VIRUSES; QUANTIFICATION; PATHOGENS;
D O I
10.1016/j.jviromet.2012.10.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Viruses are among the most important pathogens present in water contaminated with feces or urine and represent a serious risk to human health. Four procedures for concentrating viruses from sewage have been compared in this work, three of which were developed in the present study. Viruses were quantified using PCR techniques. According to statistical analysis and the sensitivity to detect human adenoviruses (HAdV), JC polyomaviruses (JCPyV) and noroviruses genogroup II (NoV GGII): (i) a new procedure (elution and skimmed-milk flocculation procedure (ESMP)) based on the elution of the viruses with glycine-alkaline buffer followed by organic flocculation with skimmed-milk was found to be the most efficient method when compared to (ii) ultrafiltration and glycine-alkaline elution, (iii) a lyophilization-based method and (iv) ultracentrifugation and glycine-alkaline elution. Through the analysis of replicate sewage samples, ESMP showed reproducible results with a coefficient of variation (CV) of 16% for HAdV, 12% for JCPyV and 17% for NoV GGII. Using spiked samples, the viral recoveries were estimated at 30-95% for HAdV, 55-90% for JCPyV and 45-50% for NoV GGII. ESMP was validated in a field study using twelve 24-h composite sewage samples collected in an urban sewage treatment plant in the North of Spain that reported 100% positive samples with mean values of HAdV, JCPyV and NoV GGII similar to those observed in other studies. Although all of the methods compared in this work yield consistently high values of virus detection and recovery in urban sewage, some require expensive laboratory equipment. ESMP is an effective low-cost procedure which allows a large number of samples to be processed simultaneously and is easily standardizable for its performance in a routine laboratory working in water monitoring. Moreover, in the present study, a CV was applied and proposed as a parameter to evaluate and compare the methods for detecting viruses in sewage samples. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 55 条
[41]  
2
[42]   Quantification and molecular characterization of enteric viruses detected in effluents from two hospital wastewater treatment plants [J].
Prado, Tatiana ;
Silva, Dalton M. ;
Guilayn, Wilma C. ;
Rose, Tatiana L. ;
Gaspar, Ana Maria C. ;
Miagostovich, Marize P. .
WATER RESEARCH, 2011, 45 (03) :1287-1297
[43]   DETECTION OF ADENOVIRUSES AND ENTEROVIRUSES IN POLLUTED WATERS BY NESTED PCR AMPLIFICATION [J].
PUIG, M ;
JOFRE, J ;
LUCENA, F ;
ALLARD, A ;
WADELL, G ;
GIRONES, R .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1994, 60 (08) :2963-2970
[44]   Detection of enteric viruses and bacterial indicators in German environmental waters [J].
Pusch, D ;
Oh, DY ;
Wolf, S ;
Dumke, R ;
Schröter-Bobsin, U ;
Höhne, M ;
Röske, I ;
Schreier, E .
ARCHIVES OF VIROLOGY, 2005, 150 (05) :929-947
[45]   Standard and new faecal indicators and pathogens in sewage treatment plants, microbiological parameters for improving the control of reclaimed water [J].
Rodriguez-Manzano, J. ;
Alonso, J. L. ;
Ferrus, M. A. ;
Moreno, Y. ;
Amoros, I. ;
Calgua, B. ;
Hundesa, A. ;
Guerrero-Latorre, L. ;
Carratala, A. ;
Rusinol, M. ;
Girones, R. .
WATER SCIENCE AND TECHNOLOGY, 2012, 66 (12) :2517-2523
[46]   Analysis of the evolution in the circulation of HAV and HEV in Eastern Spain by testing urban sewage samples [J].
Rodriguez-Manzano, Jesus ;
Miagostovich, Marize ;
Hundesa, Ayalkibet ;
Clemente-Casares, Pilar ;
Carratala, Anna ;
Buti, Maria ;
Jardi, Rosend ;
Girones, Rosina .
JOURNAL OF WATER AND HEALTH, 2010, 8 (02) :346-354
[47]  
Shah K.V., 1995, FIELDS VIROLOGY, P1997
[48]   Effective detection of human adenovirus in hawaiian waters using enhanced pcr methods [J].
Tong, Hsin-I ;
Lu, Yuanan .
VIROLOGY JOURNAL, 2011, 8
[49]   Genetic diversity of noroviruses in raw and treated sewage water [J].
van den Berg, H ;
Lodder, W ;
van der Poel, W ;
Vennema, H ;
Husman, AMD .
RESEARCH IN MICROBIOLOGY, 2005, 156 (04) :532-540
[50]  
Verzani J., 2004, USING R INTRO STAT