Parallel MR imaging: A user's guide

被引:159
作者
Glockner, JF
Hu, HH
Stanley, DW
Angelos, L
King, K
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] GE Med Syst, Milwaukee, WI USA
关键词
D O I
10.1148/rg.255045202
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel imaging is a recently developed family of techniques that take advantage of the spatial information inherent in phased-array radiofrequency coils to reduce acquisition times in magnetic resonance imaging. In parallel imaging, the number of sampled k-space lines is reduced, often by a factor of two or greater, thereby significantly shortening the acquisition time. Parallel imaging techniques have only recently become commercially available, and the wide range of clinical applications is just beginning to be explored. The potential clinical applications primarily involve reduction in acquisition time, improved spatial resolution, or a combination of the two. Improvements in image quality can be achieved by reducing the echo train lengths of fast spin-echo and single-shot fast spin-echo sequences. Parallel imaging is particularly attractive for cardiac and vascular applications and will likely prove valuable as 3-T body and cardiovascular imaging becomes part of standard clinical practice. Limitations of parallel imaging include reduced signal-to-noise ratio and reconstruction artifacts. It is important to consider these limitations when deciding when to use these techniques. (c) RSNA, 2005.
引用
收藏
页码:1279 / 1297
页数:19
相关论文
共 43 条
  • [1] Bammer Roland, 2004, Top Magn Reson Imaging, V15, P129, DOI 10.1097/01.rmr.0000139666.23921.27
  • [2] Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    [J]. CIRCULATION, 2003, 108 (11) : 1355 - 1361
  • [3] Campeau N G, 2001, Top Magn Reson Imaging, V12, P183, DOI 10.1097/00002142-200106000-00005
  • [4] IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION
    CARLSON, JW
    MINEMURA, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) : 681 - 688
  • [5] Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: Feasibility study
    de Vries, M
    Nijenhuis, RJ
    Hoogeveen, RM
    de Haan, MW
    van Engelshoven, JMA
    Leiner, T
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (01) : 37 - 45
  • [6] Coronary magnetic resonance angiography: Technical developments and clinical applications
    Dirksen, MS
    Lamb, HJ
    Doornbos, J
    Bax, JJ
    Jukema, JW
    de Roos, A
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (02) : 365 - 386
  • [7] Golay X, 2001, AM J NEURORADIOL, V22, P1615
  • [8] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [9] Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD
    Guttman, MA
    Kellman, P
    Dick, AJ
    Lederman, RJ
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 315 - 321
  • [10] Large field-of-view real-time MRI with a 32-channel system
    Hardy, CJ
    Darrow, RD
    Saranathan, M
    Giaquinto, RO
    Zhu, YD
    Dumoulin, CL
    Bottomley, PA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 878 - 884