Dual-function amperometric sensors based on poly(diallydimethylammoniun chloride)-functionalized reduced graphene oxide/manganese dioxide/gold nanoparticles nanocomposite

被引:53
作者
Zhang, Cong [1 ]
Zhang, Yanyan [1 ]
Miao, Zhiying [2 ]
Ma, Min [1 ]
Du, Xin [1 ]
Lin, Jiahui [1 ]
Han, Bingkai [1 ]
Takahashi, Shigehiro [3 ]
Anzai, Jun-ichi [3 ]
Chen, Qiang [1 ]
机构
[1] Nankai Univ, Coll Life Sci, Key Lab Bioact Mat, Minist Educ, Tianjin 300071, Peoples R China
[2] Nankai Univ, Coll Chem, State Key Lab Med Chem Biol, Tianjin 300071, Peoples R China
[3] Tohoku Univ, Grad Sch Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
关键词
Graphene; Manganese dioxide; Gold nanoparticles; Hydrogen peroxide sensor; Glucose biosensor; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL GLUCOSE BIOSENSOR; HYDROGEN-PEROXIDE; GOLD NANOPARTICLES; PRUSSIAN BLUE; OXIDE NANOCOMPOSITE; NANOTUBES; H2O2; FABRICATION; REDUCTION;
D O I
10.1016/j.snb.2015.08.114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, reduced graphene oxide (RGO)/manganese dioxide (MnO2)/gold nanoparticles (AuNPs) nanocomposite was prepared by a facile, eco-friendly and controllable route, and the morphology of RGO/MnO2/AuNPs nanocomposite was characterized by transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX) analyzer, X-ray diffraction (XRD) spectrum, and Fourier transform infrared spectrum (FT-IR), respectively. And then, taking full advantage of the synergistic effect among RGO, MnO2 and AuNPs, poly(diallyldimethylammonium chloride) (PDDA)functionalized RGO/MnO2/AuNP5 nanocomposite was immobilized on the surface of glassy carbon (GC) electrode to fabricate a novel nonenzymatic hydrogen peroxide sensor, and the results demonstrated that the sensor showed excellent electrocatalytic activity toward H2O2 with ultrahigh sensitivity of 1132.8 jiAmM(-1) cm(-2) and low detection limit of 0.6 ji,M (SIN= 3). In addition, a glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) on the surface of the PDDA-RGO/MnO2/AuNP5-modified GC electrode. In glucose determination, the glucose biosensor exhibited excellent performance with a high sensitivity of 83.7 ILA mM(-1) cm(-2), a low detection limit of 1.8 p,M (SIN= 3), and a small Km value of 1.54 mM. Moreover, the prepared hydrogen peroxide sensor and glucose biosensor were applied to in real samples with satisfactory results, indicating the prepared sensors are promising in practical application. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:663 / 673
页数:11
相关论文
共 50 条
  • [11] Electrochemical immunoassay based on gold nanoparticles and reduced graphene oxide functionalized carbon ionic liquid electrode
    Yu, Sheng
    Cao, Xiaoyu
    Yu, Meng
    MICROCHEMICAL JOURNAL, 2012, 103 : 125 - 130
  • [12] Gold Nanoparticles-electrochemically Reduced Graphene Oxide/Poly(indole-5-carboxylic acid) Nanocomposite for Electrochemical Non-enzymatic Sensing of Hydrogen Peroxide
    Tig, Gozde Aydogdu
    Zeybek, Bulent
    ELECTROANALYSIS, 2023, 35 (02)
  • [13] Highly selective and sensitive electrochemical sensor for L-cysteine detection based on graphene oxide/multiwalled carbon nanotube/manganese dioxide/gold nanoparticles composite
    Wang, Xiaojiao
    Luo, Chuannan
    Li, Leilei
    Duan, Huimin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 757 : 100 - 106
  • [14] Solvent dispersible nanocomposite based on Reduced Graphene Oxide and in-situ decorated gold nanoparticles
    Ingrosso, C.
    Corricelli, M.
    Disha, A.
    Fanizza, E.
    Bianco, G., V
    Depalo, N.
    Panniello, A.
    Agostiano, A.
    Striccoli, M.
    Curri, M. L.
    CARBON, 2019, 152 : 777 - 787
  • [15] A Novel Electrochemical Sensor Based on SH-β-cyclodextrin Functionalized Gold Nanoparticles/Reduced-Graphene Oxide Nanohybrids for Ultrasensitive Electrochemical Sensing of Acetaminophen and Ofloxacin
    Jiang, Zhiming
    Li, Guangyu
    Zhang, Mingxiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5157 - 5173
  • [16] α-Manganese Dioxide (α-MnO2) Coated with Polyaniline (PANI) and Reduced Graphene Oxide (rGO)-Based Nanocomposite for Supercapacitor Application
    Patil, Pranoti H.
    Kulkarni, Vidya V.
    Dongale, Tukaram D.
    Jadhav, Sushilkumar A.
    JOURNAL OF COMPOSITES SCIENCE, 2023, 7 (04):
  • [17] An Impedimetric Aptasensor Based on Reduced Graphene Oxide/Carbon Nanotube-Gold Nanoparticles Nanocomposite for the Detection of Pseudomonas aeruginosa
    Jia F.
    Yan W.
    Dai R.
    Liu Y.
    Li X.
    Shipin Kexue/Food Science, 2021, 42 (18): : 284 - 291
  • [18] Poly (Diallyldimethylammonium Chloride) Functionalized Reduced Graphene Oxide Based Electrochemical Sensing Platform for Luteolin Determination
    Fu, Li
    Zheng, Yuhong
    Wang, Aiwu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (04): : 3518 - 3529
  • [19] Functionalized gold nanoparticles/reduced graphene oxide nanocomposites for ultrasensitive electrochemical sensing of mercury ions based on thymine-mercury-thymine structure
    Wang, Nan
    Lin, Meng
    Dai, Hongxiu
    Ma, Houyi
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 320 - 326
  • [20] An electrochemical aptasensor based on gold nanoparticles and graphene oxide doped poly(3,4-ethylenedioxythiophene) nanocomposite for detection of MUC1
    Gupta, Pernika
    Bharti, Anu
    Kaur, Navpreet
    Singh, Suman
    Prabhakar, Nirmal
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 102 - 108