Comparison of dorsal and volar percutaneous screw fixation methods in acute Type B scaphoid fractures

被引:20
作者
Gurbuz, Yusuf [1 ]
Kayalar, Murat [1 ]
Bal, Emin [1 ]
Toros, Tulgar [1 ]
Kucuk, Levent [2 ]
Sugun, Tahir Sadik [1 ]
机构
[1] Hand Microsurg Orthopaed & Traumatol EMOT Hosp, Izmir, Turkey
[2] Ege Univ, Fac Med, Dept Orthoped & Traumatol, Izmir, Turkey
关键词
Dorsal fixation; percutaneous screw fixation; scaphoid fracture; volar fixation; CAST IMMOBILIZATION; INTERNAL-FIXATION; WAIST FRACTURES; HERBERT SCREW; PENETRATION; MANAGEMENT; WRIST;
D O I
10.3944/AOTT.2012.2816
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: In this study, we aimed to compare the clinical and functional results of patients treated with dorsal or volar percutaneous screw fixation for acute scaphoid fractures. Methods: We retrospectively evaluated 27 wrists of 26 patients (24 males, 2 females; mean age: 33.1 years) who underwent dorsal or volar percutaneous screw fixation for acute scaphoid fractures between 2000 and 2009. The dorsal approach group contained 13 wrists and the volar approach group 14 wrists. Splint was removed and wrist exercises initiated on the 10th postoperative day. Pinch power, grip power and range of motion were evaluated using the contralateral wrist as controls. Functional evaluation was performed using the patient-rated wrist evaluation score (PRWE) and Mayo wrist scoring system. Results: According to the Herbert and Fisher's classification system there were 9 B2, 3 B3 and 1 B1 fractures in the dorsal approach group, and 12 B2 and 2 B1 fractures in the volar approach group. Fracture union was achieved in all patients. There was no significant difference between the two groups according to functional and clinical results (p>0.05). All patients returned to their jobs in an average of 4.2 weeks and there was no significant difference between the groups (p=0.437). Wrist flexion was significantly better in the control wrists in both groups (p=0.009). In one patient, the screw was removed due to ongoing pain and asymptomatic screw head displacement in the scaphotrapezoid joint was detected in another. Conclusion: The surgical approach does not affect the clinical and functional outcomes in percutaneous screw fixation of Type B scaphoid fractures. Percutaneous fixation is a valuable treatment method for Type B scaphoid fractures as it enables early wrist motion and high patient satisfaction.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 36 条
[21]  
Kuschner S H, 1994, Orthop Rev, V23, P861
[22]  
Ledoux P, 1995, Acta Orthop Belg, V61, P43
[23]   Retrograde (volar) scaphoid screw insertion - A quantitative computed tomographic analysis [J].
Levitz, S ;
Ring, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03) :543-548
[24]  
MacDermid J C, 1996, J Hand Ther, V9, P178
[25]   Patient rating of wrist pain and disability: A reliable and valid measurement tool [J].
MacDermid, JC ;
Turgeon, T ;
Richards, RS ;
Beadle, M ;
Roth, JH .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (08) :577-586
[26]   Percutaneous screw fixation versus conservative treatment for fractures of the waist of the scaphoid - A prospective randomised study [J].
McQueen, M. M. ;
Gelbke, M. K. ;
Wakefield, A. ;
Will, E. M. ;
Gaebler, C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (01) :66-71
[27]   Percutaneous fixation of selected scaphoid fractures by dorsal approach [J].
Naranje, Sameer ;
Kotwal, P. P. ;
Shamshery, P. ;
Gupta, Vikas ;
Nag, H. L. .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (07) :997-1003
[28]   INTERNAL-FIXATION OF ACUTE SCAPHOID FRACTURES - A NEW APPROACH TO TREATMENT [J].
OBRIEN, L ;
HERBERT, T .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1985, 55 (04) :387-389
[29]  
Omer G E Jr, 1986, Hand Clin, V2, P193
[30]   Percutaneous internal fixation of selected scaphoid nonunions with an arthroscopically assisted dorsal approach [J].
Slade, JF ;
Geissler, WB ;
Gutow, AP ;
Merrell, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :20-32