Effect of R-phase Heat Treatment on Torsional Resistance and Cyclic Fatigue Fracture

被引:75
作者
Ha, Jung-Hong [1 ]
Kim, Sung Kyo [1 ]
Cohenca, Nestor [2 ]
Kim, Hyeon-Cheol [3 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Conservat Dent, Taegu, South Korea
[2] Univ Washington, Dept Endodont, Seattle, WA 98195 USA
[3] Pusan Natl Univ, Sch Dent, Dept Conservat Dent, Yangsan 626787, Gyeongnam, South Korea
关键词
Cyclic fatigue; K3XF; NiTi rotary file; R-phase heat treatment; torsional resistance; TITANIUM ROTARY FILES; STAINLESS-STEEL FILES; MECHANICAL-PROPERTIES; CANAL PREPARATIONS; FLEXURAL FATIGUE; ENGINE-DRIVEN; PROFILE GT; INSTRUMENTS; HAND; STIFFNESS;
D O I
10.1016/j.joen.2012.11.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to investigate whether the resistance to torsional stress and cyclic fatigue would be improved by the novel R-phase heat treatment by using instruments with identical geometric characteristics. Methods: K3XF and K3 files with sizes of #30/.04 and #30/.06 were selected for the study (n = 10 per group). To evaluate the torsional resistance, the torsional load and distortion angle at yield, ultimate, and fracture points were recorded. The toughness until fracture was calculated as well. The number of cycles to failure for each instrument was determined to evaluate the cyclic fatigue resistance. Statistical analysis was performed by using the nonparametric Mann-Whitney U test (for torsional resistance) and independent t test (for cyclic fatigue). After torsional and cyclic fatigue tests, all fractured fragments were observed under a scanning electron microscope to evaluate the topographic features of the fractured surfaces. Results: Although K3XF showed superior cyclic fatigue resistance to K3 (P < .000), there was no significant difference in torsional resistance in terms of ultimate strength, fracture angle, and toughness between the 2 brands of K3XF and K3 regardless of the instruments' taper. The fractured cross-sectional surfaces showed typical features of cyclic fatigue and torsional fractures. K3XF had a distinctive surface with numerous irregular micropores. Conclusions: The heat-treated K3XF instruments that used R-phase heat treatment technology showed improved cyclic fatigue resistance without decline of torsional strength. (J Ended 2013;39:389-393)
引用
收藏
页码:389 / 393
页数:5
相关论文
共 32 条
  • [1] Evaluation of Cyclic Flexural Fatigue of M-Wire Nickel-Titanium Rotary Instruments
    Al-Hadlaq, Solaiman M. S.
    AlJarbou, Fahad A.
    AlThumairy, Riyadh I.
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (02) : 305 - 307
  • [2] SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    Alapati, SB
    Brantley, WA
    Svec, TA
    Powers, JM
    Nusstein, JM
    Daehn, GS
    [J]. JOURNAL OF ENDODONTICS, 2005, 31 (01) : 40 - 43
  • [3] Evaluation of single-use rotary nickel-titanium instruments
    Arens, FC
    Hoen, MM
    Steiman, HR
    Dietz, GC
    [J]. JOURNAL OF ENDODONTICS, 2003, 29 (10) : 664 - 666
  • [4] Comparison of Torsional Stiffness of Nickel-Titanium Rotary Files with Different Geometric Characteristics
    Baek, Seung-Ho
    Lee, Chan-Joo
    Versluis, Antheunis
    Kim, Byung-Min
    Lee, WooCheol
    Kim, Hyeon-Cheol
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (09) : 1283 - 1286
  • [5] Resistance to Cyclic Fatigue Failure of a New Endodontic Rotary File
    Bouska, Jason
    Justman, Bruce
    Williamson, Anne
    DeLong, Christopher
    Qian, Fang
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (05) : 667 - 669
  • [6] A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique
    Chen, JL
    Messer, HH
    [J]. AUSTRALIAN DENTAL JOURNAL, 2002, 47 (01) : 12 - 20
  • [7] Cheung G. S., 2007, ENDODONTIC TOPICS, V16, P1, DOI [10.1111/j.1601-1546.2009.00239.x, DOI 10.1111/J.1601-1546.2009.00239.X]
  • [8] Flexural Fatigue and Torsional Resistance of ProFile GT and ProFile GT Series X Instruments
    da Cunha Peixoto, Isabella Faria
    Joviano Pereira, Erika Sales
    da Silva, Jacqueline Goncalves
    Diniz Viana, Ana Cecilia
    Lopes Buono, Vicente Tadeu
    de Azevedo Bahia, Maria Guiomar
    [J]. JOURNAL OF ENDODONTICS, 2010, 36 (04) : 741 - 744
  • [9] Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique
    Gambarini, G.
    Plotino, G.
    Grande, N. M.
    Al-Sudani, D.
    De Luca, M.
    Testarelli, L.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) : 337 - 341
  • [10] Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods
    Gambarini, Gianluca
    Grande, Nicola Maria
    Plotino, Gianluca
    Somma, Francesco
    Garala, Manish
    De Luca, Massimo
    Testarelli, Luca
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (08) : 1003 - 1005