The use of near-infrared and microwave resonance sensing to monitor a continuous roller compaction process

被引:32
作者
Austin, John [1 ]
Gupta, Anshu [1 ]
Mcdonnell, Ryan [1 ]
Reklaitis, Gintaras V. [1 ]
Harris, Michael T. [1 ]
机构
[1] Purdue Univ, Sch Chem Engn, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
granulation; physical characterization; multivariate analysis; near-infrared spectroscopy; powder technology; processing; automation; microwave sensing; MOISTURE-CONTENT; DENSITY; SPECTROSCOPY; REFLECTANCE; TECHNOLOGY; SPECTRA; TABLETS; POWDERS; SOLIDS; DEPTH;
D O I
10.1002/jps.23536
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Roller compaction is commonly used in the pharmaceutical and nutraceutical industries to increase and narrow the size distribution of a particulate material, making it easier to process. Both the moisture content of the material and the density of the roller compacted ribbon affect the uniformity and physical properties of the resultant granules. Without process analytical technologies, these parameters cannot be determined on-line or in real time. In this study, the more commonly used near-infrared (NIR) spectroscopy was compared and contrasted with microwave resonance for the determination of roller-compacted ribbons' envelope density and moisture content. Results indicate that microwave resonance can offer improved accuracy, robustness, and ease-of-use compared with NIR spectroscopy for these property measurements. (c) 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:18951904, 2013
引用
收藏
页码:1895 / 1904
页数:10
相关论文
共 29 条
  • [1] Evaluation of Three Approaches for Real-Time Monitoring of Roller Compaction with Near-Infrared Spectroscopy
    Acevedo, David
    Muliadi, Ariel
    Giridhar, Arun
    Litster, James D.
    Romanach, Rodolfo J.
    [J]. AAPS PHARMSCITECH, 2012, 13 (03): : 1005 - 1012
  • [2] A Quantitative Correlation of the Effect of Density Distributions in Roller-Compacted Ribbons on the Mechanical Properties of Tablets Using Ultrasonics and X-ray Tomography
    Akseli, Ilgaz
    Iyer, Srinivas
    Lee, Hwahsiung P.
    Cuitino, Alberto M.
    [J]. AAPS PHARMSCITECH, 2011, 12 (03): : 834 - 853
  • [3] [Anonymous], GUID IND PATA FRAM I
  • [4] Utilizing microwaves for the determination of moisture content independent of density
    Austin, John
    Rodriguez, Sheila
    Sung, Pei-Fang
    Harris, Michael
    [J]. POWDER TECHNOLOGY, 2013, 236 : 17 - 23
  • [5] STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA
    BARNES, RJ
    DHANOA, MS
    LISTER, SJ
    [J]. APPLIED SPECTROSCOPY, 1989, 43 (05) : 772 - 777
  • [6] In-line monitoring of granule moisture in fluidized-bed dryers using microwave resonance technology
    Buschmueller, Caroline
    Wiedey, Wolfgang
    Doescher, Claas
    Dressler, Jochen
    Breitkreutz, Joerg
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2008, 69 (01) : 380 - 387
  • [7] The influence of data pre-processing in the pattern recognition of excipients near-infrared spectra
    Candolfi, A
    De Maesschalck, R
    Jouan-Rimbaud, D
    Hailey, PA
    Massart, DL
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (01) : 115 - 132
  • [8] RELATIONSHIP OF LEAF SPECTRAL REFLECTANCE TO CHLOROPLAST WATER-CONTENT DETERMINED USING NMR MICROSCOPY
    CARTER, GA
    MCCAIN, DC
    [J]. REMOTE SENSING OF ENVIRONMENT, 1993, 46 (03) : 305 - 310
  • [9] Chen L, 2004, MATER RES SOC SYMP P, V782, P37
  • [10] Comparison of near infrared and microwave resonance sensors for at-line moisture determination in powders and tablets
    Corredor, Claudia C.
    Bu, Dongsheng
    Both, Douglas