Use of CAD-based pre-bent implants reduces theatre time in orbital floor reconstruction: results of a prospective study
被引:7
|作者:
von Wilmowsky, C.
[1
]
Schwertner, M. G.
[1
]
Nkenke, E.
[2
]
Moest, T.
[1
]
Adler, W.
[3
]
Ebker, T.
[4
,5
,6
,7
]
机构:
[1] Univ Erlangen Nurnberg, Dept Oral & Maxillofacial Surg, Glueckstr 11, D-91054 Erlangen, Germany
[2] Univ Vienna, Dept Oral & Maxillofacial Surg, Waehrigner Guertel 18-20, A-1090 Vienna, Austria
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Waldstr 6, D-91054 Erlangen, Germany
[4] Charite Univ Med Berlin, Dept Oral & Maxillofacial Surg, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Free Univ Berlin, Augustenburger Pl 1, D-13353 Berlin, Germany
[6] Humboldt Univ, Augustenburger Pl 1, D-13353 Berlin, Germany
[7] Berlin Inst Hlth, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词:
intraoperative time comparison;
individually pre-bent titanium mesh;
computer-aided design;
orbital floor fracture;
orbital floor reconstruction;
BLOWOUT FRACTURES;
TITANIUM MESHES;
WALL;
BONE;
DEFECTS;
DESIGN;
REPAIR;
D O I:
10.1016/j.bjoms.2019.11.020
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
In this prospective study we evaluated the duration of insertion and the accuracy of fitting of computer-aided design (CAD)-based pre bent orbital floor plates compared with non-preformed orbital plates in reconstruction of the orbital floor. Thirty-six patients with unilateral fractures of the orbital floor were included; pre-bent plates were used in 25 and non-preformed plates in 11. Preoperative computed tomography (CT) scans were used for CAD of individualised implants. The anatomy of the affected orbit was virtually reconstructed "slice by slice". Individually pre-bent plates were generated using a stereolithographic model of the reconstructed orbit. The mean (SD) duration of insertion was significantly reduced when pre-bent orbital plates were used (5.5 (5.4) min) compared with non-preformed meshes (11.1 (7.7) min). The congruence of pre-bent plates to the infraorbital rim did not differ from that of non-preformed plates. The accuracy of fit was rated as "accurate" in 24 cases. CAD-based individualised titanium meshes reduce theatre time compared with non-preformed orbital plates. Our results confirm the efficacy of CAD-based pre-bent plates in reconstruction of the orbital floor. (C) 2019 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.