On Partial Discharge/Corona Considerations for Low Voltage Switchgear and Controlgear

被引:0
|
作者
Weichert, Hans [1 ]
Benz, Pascal [1 ]
Hill, Nicholas [2 ]
Hilbert, Michael [2 ]
Kurrat, Michael [2 ]
机构
[1] Rockwell Automat Switzerland GmbH, Aarau, Switzerland
[2] Tech Univ Carolo Wilhelmina Braunschweig, Braunschweig, Germany
来源
PROCEEDINGS OF 2018 29TH INTERNATIONAL CONFERENCE ON ELECTRICAL CONTACTS AND 64TH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS | 2018年
关键词
Partial discharge; corona; electrical field; manual motor controller; operational temperature; low voltage; variable frequency converters;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical field and partial discharge (PD, corona) considerations usually are not in the foreground with low voltage switch- and control gear as per the product standards of IEC, UL and CSA. The design is mainly based on creepage and clearance dimensions, material categories described through CTI and RTI values. IEC product standards refer to the subject of insulation coordination as per the horizontal IEC 60664-family in their normative references. These standards, in principle, require PD measurements for rated voltages exceeding 500 VAC at room temperature. IEC 60664-2 gives some rules for consideration and electrical dimensioning of solid insulation. Miniaturization accompanied by increased power density and raised operational voltage as well as (non-sinusoidal) power supply generated by pulse width modulated (PWM) converters require to reconsider the relevance of electrical field stress in low voltage equipment. With variable frequency drive (VFD) fed motors reflected voltage waves were observed, causing partial discharge effects and insulation damages. Meanwhile motors and cables are available as VFD-proof versions. PD measurements on commercial manual motor controllers with sinusoidal voltages at both room temperature and a more severe elevated temperature related to the maximal operational temperature of the internal components (bimetal trip units) are presented. Conclusions are drawn and recommendations for future designs and testing are proposed.
引用
收藏
页码:246 / 253
页数:8
相关论文
共 50 条
  • [21] Experimental Studies on Air Humidity Affecting Partial Discharge in Switchgear
    Meng, Fansheng
    Zhang, Xiaoxing
    Wu, Xiaoqing
    Xu, Bin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1237 - 1241
  • [22] Detection of Multiple Partial Discharge Faults in Switchgear and Power Cables
    Hussain, Ghulam Amjad
    Hummes, Detlef
    Shafiq, Muhammad
    Safdar, Madia
    2019 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2019,
  • [23] Detection and Analysis of Typical Fault Partial Discharge Characteristics in Switchgear
    Kang, Yin-zhu
    Li, Yong-xiang
    Yang, Gang
    Wang, Tian-Zheng
    Guo, Li-qiang
    Wang, Zhi-peng
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 76 - 80
  • [24] Study on a partial discharge test for low-voltage electronic components
    Kil, Gyung-Suk
    Song, Jae-Yong
    Song, Jae-Man
    Hwang, Don-Ha
    Kang, Dong-Sik
    Kim, Yong-Ju
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2006, 49 (06) : 2311 - 2315
  • [25] Increasing Partial Discharge Inception Voltage at Low Pressures Using Electrets
    Saha, Pradip Chandra
    Faruqe, Omar
    Juberi, Asif Muhammad
    Park, Chanyeop
    2024 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ITEC 2024, 2024,
  • [26] Low Cost Transient Earth Voltage Probe for Partial Discharge Detection
    Malek, N. A. Abdul
    Ahmad, M. H.
    Nawawi, Z.
    Sidik, M. A. B.
    Jambak, M. I.
    2019 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND COMPUTER SCIENCE (ICECOS 2019), 2019, : 63 - 67
  • [27] Partial Discharge Detection with Bushing Sensors for Switchgear: Separation, Location, and Recognition
    Han, Tao
    Hao, Chunlin
    Gao, Yu
    Du, Boxue
    Cavallini, Andrea
    IEEE ELECTRICAL INSULATION MAGAZINE, 2025, 41 (01) : 5 - 14
  • [28] Ultrasonic-TEV Combined Detection Technology of Partial Discharge in Switchgear
    Sun Y.
    Song Y.
    Wang H.
    Hou J.
    Han X.
    Li J.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5052 - 5060
  • [29] Partial Discharge Detection and Diagnosis in Gas Insulated Switchgear: State of the Art
    Khan, Qasim
    Refaat, Shady S.
    Abu-Rub, Haitham
    Toliyat, Hamid A.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2019, 35 (04) : 16 - 33
  • [30] Spectrum characteristics of transient earth voltages aroused by partial discharge in switchgear
    Electric Power Research Institute, Guangdong Power Grid Co., Ltd., Guangzhou
    510080, China
    不详
    200240, China
    不详
    300384, China
    Gaodianya Jishu, 11 (3849-3857): : 3849 - 3857