Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator

被引:46
作者
Chang, Zheng [1 ]
Wang, Zhiheng [1 ]
Wu, Q. Jackie [1 ]
Yan, Hui [1 ]
Bowsher, Jim [1 ]
Zhang, Junan [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
high definition multileaf collimator; Novalis Tx system; radiosurgery;
D O I
10.1118/1.2977668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new Novalis Tx system equipped with a high definition multileaf collimator (HDMLC) recently became available to perform both image-guided radiosurgery and conventional radiotherapy. It is capable of delivering a highly conformal radiation dose with three energy modes: 6 MV photon energy, 15 MV photon energy, and 6 MV photon energy in a stereotactic radiosurgery mode with 1000 MU/min dose rate. Dosimetric characteristics of the new Novalis Tx treatment unit with the HDMLC are systematically measured for commissioning. A high resolution diode detector and miniion-chamber detector are used to measure dosimetric data for a range of field sizes from 4X4 mm to 400X400 mm. The commissioned Novalis Tx system has passed the RPC stereotactic radiosurgery head phantom irradiation test. The Novalis Tx system not only expands its capabilities with three energy modes, but also achieves better beam conformity and sharer beam penumbra with HDMLC. Since there is little beam data information available for the new Novalis Tx system, we present in this work the dosimetric data of the new modality for reference and comparison. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4460 / 4463
页数:4
相关论文
共 10 条
[1]  
BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475
[2]   Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery [J].
Cosgrove, VP ;
Jahn, U ;
Pfaender, M ;
Bauer, S ;
Budach, V ;
Wurm, RE .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :325-336
[3]   Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods [J].
Ding, GX ;
Duggan, DM ;
Coffey, CW .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :2549-2566
[4]   DOSIMETRIC CHARACTERISTICS OF A COMMERCIAL MULTILEAF COLLIMATOR [J].
HUQ, MS ;
YU, Y ;
CHEN, ZP ;
SUNTHARALINGAM, N .
MEDICAL PHYSICS, 1995, 22 (02) :241-247
[5]   Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition [J].
McKerracher, C ;
Thwaites, DI .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2143-2160
[6]   Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment [J].
Shiu, AS ;
Kooy, HM ;
Ewton, JR ;
Tung, SS ;
Wong, J ;
Antes, K ;
Maor, MH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03) :679-688
[7]  
WANG Z, 2008, 50 AAPM ANN M
[8]   Physical characteristics of a miniature multileaf collimator [J].
Xia, P ;
Geis, P ;
Xing, L ;
Ma, C ;
Findley, D ;
Forster, K ;
Boyer, A .
MEDICAL PHYSICS, 1999, 26 (01) :65-70
[9]   Dosimetric characteristics of Novalis shaped beam surgery unit [J].
Yin, FF ;
Zhu, JG ;
Yan, H ;
Gaun, HQ ;
Hammoud, R ;
Ryu, S ;
Kim, JH .
MEDICAL PHYSICS, 2002, 29 (08) :1729-1738
[10]   Total scatter factors and tissue maximum ratios for small radiosurgery fields: Comparison of diode detectors, a parallel-plate ion chamber, and radiographic film [J].
Zhu, XR ;
Allen, JJ ;
Shi, J ;
Simon, WE .
MEDICAL PHYSICS, 2000, 27 (03) :472-477