Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines

被引:0
|
作者
Wang, Guangzhou [1 ]
Yao, Degui [1 ]
Zhang, Songyang [1 ]
Wang, Donghui [1 ]
Wang, Leilei [1 ]
Guo, Xing [1 ]
Yang, Fan [2 ]
机构
[1] State Grid Henan Elect Power Res Inst, Zhengzhou 450052, Peoples R China
[2] Chongqing Univ, Chongqing 400044, Peoples R China
关键词
D O I
10.1088/1755-1315/467/1/012098
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Aiming at the typical AC/DC parallel transmission lines which have been put into operation in China, the electromagnetic environment of parallel transmission lines is monitored and the interaction between AC and DC electromagnetic environment is analyzed. Monitoring results show that: The electromagnetic environment of UHV AC/DC parallel transmission lines meets the corresponding national standard limits. UHV DC transmission line has little influence on power frequency electromagnetic field, which is mainly affected by distance and wire height to ground. UHV AC transmission line may have a certain impact on DC composite field strength, and wind speed will have a greater impact on DC composite field strength.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Numerical simulation of windage yaw of 500kV uhv transmission lines
    Liu, Xiao-Hui
    Yan, Bo
    Lin, Xue-Song
    Li, Wen-Yun
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (01): : 244 - 249
  • [42] Research on DC Component Decay Time Constant of 1000 kV AC Filter Circuit Breakers in UHV Converter Station
    Li, Z.
    Fan, M.
    Zha, Z.
    Zhou, P.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [43] Based on the TLM Method 1000kV UHV Transmission Line Performance Analysis
    Li Fengxia
    Wang Yuelong
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 2917 - 2922
  • [44] Wind tunnel test on 1000 kV UHV AC double circuit transmission tower-conductor coupling system
    Xie, Qiang
    Yan, Cheng-Yong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (04): : 900 - 906
  • [45] Study on Parameters Design and Corona Characteristics Test Equivalent of Grading Rings for 1000kV UHV AC Compact Transmission Line
    Huang, Daochun
    Zheng, Zheng
    Huang, Zhengfang
    Xie, Xiongjie
    Ruan, Jiangjun
    Huo, Feng
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 638 - 642
  • [46] Shaking table tests on 1000 kV UHV AC double circuit transmission tower-conductor coupling systems
    Bai, J. (baishankui@126.com), 1600, Chinese Society for Electrical Engineering (33):
  • [47] The System Reliability Analysis of 1000 kV UHV Transmission Tower Based on Moment Method
    Li, Maohua
    Li, Zhengliang
    Yu, Dengke
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT A, 2012, 16 : 166 - 171
  • [48] Study on the difference of chemical composition of insulator contamination on UHV-AC and -DC transmission lines
    Li, Lee
    Jiang, Yunpeng
    Lu, Ming
    Liu, Zehui
    Hua, Kui
    Li, Zhe
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (01) : 17 - 24
  • [49] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114):
  • [50] THE DEVELOPMENT OF 1500-KV UHV TRANSMISSION STRUCTURES
    MADUGULA, MKS
    DAVALATH, GSR
    CIVIL ENGINEERING FOR PRACTICING AND DESIGN ENGINEERS, 1985, 4 (12): : 985 - 994