Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines

被引:0
|
作者
Wang, Guangzhou [1 ]
Yao, Degui [1 ]
Zhang, Songyang [1 ]
Wang, Donghui [1 ]
Wang, Leilei [1 ]
Guo, Xing [1 ]
Yang, Fan [2 ]
机构
[1] State Grid Henan Elect Power Res Inst, Zhengzhou 450052, Peoples R China
[2] Chongqing Univ, Chongqing 400044, Peoples R China
关键词
D O I
10.1088/1755-1315/467/1/012098
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Aiming at the typical AC/DC parallel transmission lines which have been put into operation in China, the electromagnetic environment of parallel transmission lines is monitored and the interaction between AC and DC electromagnetic environment is analyzed. Monitoring results show that: The electromagnetic environment of UHV AC/DC parallel transmission lines meets the corresponding national standard limits. UHV DC transmission line has little influence on power frequency electromagnetic field, which is mainly affected by distance and wire height to ground. UHV AC transmission line may have a certain impact on DC composite field strength, and wind speed will have a greater impact on DC composite field strength.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] FORCED EXTINCTION CHARACTERISTICS OF SECONDARY ARC ON UHV (1000KV CLASS) TRANSMISSION-LINES
    GODA, Y
    MATSUDA, S
    INABA, T
    OZAKI, Y
    MOUSA, AM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1322 - 1330
  • [32] Electric power transmission at voltages of 1 000 kV AC or ± 600 kV DC and above. Network problems and solutions peculiar to UHV AC transmission
    Manzoni, G.
    Annestrand, S.A.
    Cardoso, R.
    Ichida, Y.
    Thione, L.
    Ware, B.J.
    Porrino, A.
    Britten, A.C.
    Eslinger, R.
    Jonsson, U.
    Kartashev, I.I.
    Electra, 1989, (122): : 40 - 75
  • [33] Analysis of Electromagnetic Environment Optimization Measures for UHV Transmission Lines
    Shang, Liqun
    Zhu, Weiwei
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 8975 - 8978
  • [34] Study on the influence of 1000kV AC lines on the parallel UHVDC transmission lines and its mitigation
    Li Xin-nian
    Jiang Wei-ping
    Li Tao
    Zeng Zhao-hua
    Wu Ya-ni
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 393 - +
  • [35] Analysis of Abnormal Defects of High Resistance of 1000 kV UHV Transmission Line
    Yu Bing
    Zhou Luyao
    Yang Zhi
    Zhao Lin
    Lin Haofan
    Yang Yong
    2021 THE 6TH INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM 2021), 2021, : 362 - 365
  • [36] Research on optimisation of minimum air clearance of 1000kV UHV AC substation
    Li Zhenqiang
    Xie Liang
    Liu Jing
    He Huiwen
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2687 - 2692
  • [37] Research on Safety Protection of ±800kV UHV DC Line Live Working
    Peng Yong
    Liu Kai
    Wu Tian
    Huang Zehua
    Zhang, Cimeng
    Zhang Yadi
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 958 - 961
  • [38] Optimal compensating scheme for limiting secondary arc current of 1000-kV UHV short parallel lines
    Xu, Z. Y.
    Zhang, X.
    Yan, X. Q.
    Wen, A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (12) : 1235 - 1242
  • [39] Method for measuring the electric field strength under UHV/EHV AC/DC parallel transmission lines
    Yang Zhaoguang
    Wen Dingjun
    Gao Lichao
    Bao Yanyan
    Chen Bodong
    2017 3RD INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE (EEMS 2017), 2017, 94
  • [40] Study on pollution flashover performance of short sample of ±800kV UHV DC composite insulators
    Li, Li-Cheng
    Jiang, Xing-Liang
    Sun, Cai-Xin
    Zhang, Zhi-Jin
    Hu, Jian-Lin
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (10): : 14 - 19