Simulation and Experimental Verification of Edge Blurring Phenomenon in Microdefect Inspection Based on High-Frequency Ultrasound

被引:18
|
作者
Su, Lei [1 ,2 ]
Yu, Xiaonan [1 ]
Li, Ke [1 ]
Yao, Xingyan [3 ]
Pecht, Michael [4 ]
机构
[1] Jiangnan Univ, Jiangsu Key Lab Adv Food Mfg Equipment & Technol, Wuxi 214122, Peoples R China
[2] Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
[3] Chongqing Technol & Business Univ, Chongqing Engn Lab Detect Control & Integrated Sy, Chongqing 400067, Peoples R China
[4] Univ Maryland, Ctr Adv Life Cycle Engn, College Pk, MD 20742 USA
来源
IEEE ACCESS | 2019年 / 7卷
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Microdefects; acoustic micro-imaging; edge blurring; acoustic propagation map; SOLDER; DIAGNOSIS; DEFECTS;
D O I
10.1109/ACCESS.2019.2892231
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Acoustic micro-imaging based on high-frequency ultrasound has been widely and effectively used for microdefect detection in microelectronic packages. With the miniaturization of microelectronic devices and the reduction of defects, edge blurring occurs in high-frequency ultrasonic scanning and directly affects the detection accuracy and signal-to-noise ratio, especially in spherical structures, such as ball grid arrays, wafer-level chip-scale packaging, and flip-chip solder bumps. This paper depicts the ultrasound interaction behaviors and the edge blurring effects during microdefect imaging, which provide a theoretical basis for improving the defect detection accuracy in subsequent research. A microdefect finite-element model was developed to simulate scanning in acoustic microscopy imaging. C-lines and C-scans of microdefects of various sizes were obtained, which can identify the location and size of the defects more easily. Furthermore, an improved method to obtain the acoustic propagation path map was developed for analyzing the acoustic energy transmission during detection. Different energy consumption paths around the microdefect lead to differences among the C-lines. The different sizes of microdefects show different blurred edges in the C-scans. The experimental data and simulation show consistent results, which prove the credibility of the developed method.
引用
收藏
页码:11515 / 11525
页数:11
相关论文
共 50 条
  • [1] Image enlargement with high-frequency component augmentation based on predefined codebook describing edge blurring properties
    Hideaki Kawano
    Hakaru Tamukoh
    Noriaki Suetake
    Byungki Cha
    Takashi Aso
    Optical Review, 2010, 17 : 447 - 453
  • [2] Image Enlargement with High-Frequency Component Augmentation Based on Predefined Codebook Describing Edge Blurring Properties
    Kawano, Hideaki
    Tamukoh, Hakaru
    Suetake, Noriaki
    Cha, Byungki
    Aso, Takashi
    OPTICAL REVIEW, 2010, 17 (05) : 447 - 453
  • [3] EXPERIMENTAL CATARACT PRODUCTION BY HIGH-FREQUENCY ULTRASOUND
    LIZZI, FL
    PACKER, AJ
    COLEMAN, DJ
    ANNALS OF OPHTHALMOLOGY, 1978, 10 (07): : 934 - 942
  • [4] EXPERIMENTAL OCULAR LESIONS PRODUCED BY HIGH-FREQUENCY ULTRASOUND
    LIZZI, FL
    PACKER, A
    COLEMAN, DJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 : S59 - S60
  • [5] Optimization Design and Experimental Verification of Nanocrystalline High-frequency Transformer
    Zhang, Pengning
    Li, Wei
    Li, Pengyang
    Yang, Yajin
    Li, Bofan
    Zhang, Jian
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (10): : 4475 - 4486
  • [6] Magneto-thermal coupling simulation and experimental verification for a three-winding high-frequency transformer
    Xu, Yadi
    Li, Lin
    Yuan, Xuan
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2022, 68 (02) : 159 - 175
  • [7] Analytical and experimental approach to high-frequency transformer simulation
    Dallago, E
    Venchi, G
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (03) : 415 - 421
  • [8] Simulation Research on Sparse Reconstruction for Defect Signals of Flip Chip Based on High-Frequency Ultrasound
    Yu, Xiaonan
    Huang, Hairun
    Xie, Wanlong
    Gu, Jiefei
    Li, Ke
    Su, Lei
    APPLIED SCIENCES-BASEL, 2020, 10 (04):
  • [9] IMPACT OF HIGH-FREQUENCY PULSE ULTRASOUND ON EXPERIMENTAL MYOCARDIAL-INFARCTION
    MROCHEK, AG
    BULGAK, AG
    SYTYI, VP
    KOVALENKO, YD
    KARDIOLOGIYA, 1992, 32 (05) : 55 - 57
  • [10] Numerical and experimental studies of a morphing airfoil with trailing edge high-frequency flapping
    Zhang, Wei
    Chen, Lei
    Xia, Zhixun
    Nie, Xutao
    Ou, Liwei
    Gao, Rong
    PHYSICS OF FLUIDS, 2023, 35 (12)