Exhaled Acetone as a New Biomarker of Heart Failure Severity
被引:77
作者:
Marcondes-Braga, Fabiana G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Marcondes-Braga, Fabiana G.
[1
]
Gutz, Ivano G. R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Inst Chem, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Gutz, Ivano G. R.
[2
]
Batista, Guilherme L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Inst Chem, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Batista, Guilherme L.
[2
]
Saldiva, Paulo H. N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Sch Med, Lab Expt Air Pollut, Dept Pathol, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Saldiva, Paulo H. N.
[3
]
Ayub-Ferreira, Silvia M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Ayub-Ferreira, Silvia M.
[1
]
Issa, Victor S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Issa, Victor S.
[1
]
Mangini, Sandrigo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Mangini, Sandrigo
[1
]
Bocchi, Edimar A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Bocchi, Edimar A.
[1
]
Bacal, Fernando
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, BrazilUniv Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
Bacal, Fernando
[1
]
机构:
[1] Univ Sao Paulo, Lab Heart Failure, Heart Inst InCor, Hosp Clin,Fac Med, Sao Paulo, Brazil
[2] Univ Sao Paulo, Inst Chem, Sao Paulo, Brazil
[3] Univ Sao Paulo, Sch Med, Lab Expt Air Pollut, Dept Pathol, Sao Paulo, Brazil
Background: Heart failure (HF) is associated with poor prognosis, and the identification of biomarkers of its severity could help in its treatment. In a pilot study, we observed high levels of acetone in the exhaled breath of patients with HF. The present study was designed to evaluate exhaled acetone as a biomarker of HF diagnosis and HF severity. Methods: Of 235 patients with systolic dysfunction evaluated between May 2009 and September 2010, 89 patients (HF group) fulfilled inclusion criteria and were compared with sex- and age-matched healthy subjects (control group, n = 20). Patients with HF were grouped according to clinical stability (acute decompensated HF [ADHF], n = 59; chronic HF, n = 30) and submitted to exhaled breath collection. Identification of chemical species was done by gas chromatography-mass spectrometry and quantification by spectrophotometry. Patients with diabetes were excluded. Results: The concentration of exhaled breath acetone (EBA) was higher in the HF group (median, 3.7 mu g/L; interquartile range [IQR], 1.69-10.45 mu g/L) than in the control group (median, 0.39 mu g/L; IQR, 0.30-0.79 mu g/L; P < .001) and higher in the ADHF group (median, 7.8 mu g/L; IQR, 3.6-15.2 mu g/L) than in the chronic HF group (median, 1.22 mu g/L; IQR, 0.68-2.19 P < .001). The accuracy and sensitivity of this method in the diagnosis of HF and ADHF were about 85%, a value similar to that obtained with B-type natriuretic peptide (BNP). EBA levels differed significantly as a function of severity of HF (New York Heart Association classification, P < .001). There was a positive correlation between EBA and BNP (r = 0.772, P < .001). Conclusions: EBA not only is a promising noninvasive diagnostic method of HF with an accuracy equivalent to BNP but also a new biomarker of HF severity. CHEST 2012; 142(2):457-466
机构:
Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
Massachusetts Gen Hosp, Ctr Immunol & Inflammatory Dis, Charlestown, MA 02129 USAMassachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
Gerszten, Robert E.
;
Wang, Thomas J.
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USAMassachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
机构:
Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
Massachusetts Gen Hosp, Ctr Immunol & Inflammatory Dis, Charlestown, MA 02129 USAMassachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA
Gerszten, Robert E.
;
Wang, Thomas J.
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USAMassachusetts Gen Hosp, Div Cardiol, Boston, MA 02114 USA