Numerical Simulation of Airflow Around Cooling Towers in Semi-closed Space

被引:2
作者
Zhu Yanhe [1 ]
Deng Yahong [2 ]
Li Chang [2 ]
Zeng Junyong [1 ]
Wu Xuezhi [2 ]
Zhong Jian [2 ]
Jiang Changwei [1 ]
机构
[1] Changsha Univ Sci & Technol, Coll Energy & Power Engn, Changsha 410004, Hunan, Peoples R China
[2] Second Construct Engn Co LTD, Bur 3 CSCEC, Wuhan 430074, Hubei, Peoples R China
来源
10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017 | 2017年 / 205卷
关键词
Cooling tower; Air distribution; Numerical simulatio; PERFORMANCE; OPTIMIZATION;
D O I
10.1016/j.proeng.2017.09.939
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As an important part of the air conditioning system, the operating performance of the cooling tower has a direct impact on heating and refrigeration of the air conditioning system. Now the cooling towers are placed in the room in many high-end buildings, which results in poor ventilation of the cooling towers. In order to improve the efficiency of the cooling towers, the organized air exhaust scheme of cooling towers should be adopted to reduce or prevent the back-mixing of humid air around the cooling towers. A design method of tower group operation performance in semi-closed space was proposed and the air distribution around the cooling towers in semi-closed space under the organized air exhaust scheme was simulated numerically in this paper. The object of this study is a super high-rise building with 10 layers podium and 164 layers main building. The cooling tower room is 67.3m long, 65m wide and 21.6m high, 13 sets of cooling towers are installed in the cooling tower room. The complicated actually physical structure is simplified and the areas of inlet and outlet are established according to the actual area of 50% in the process of numerical simulation. The airflow distribution and flow resistance characteristics around the cooling towers were obtained through the numerical simulation of air-flow organization around cooling towers. The numerical results show that the exhaust air of cooling towers can be expelled from the semi-closed space smoothly with the organization of air exhaust and the airflow in cooling tower machine room is relatively stable, the inlet air volume of cooling towers can reach rated air flow rate and the cooling towers can run efficiently under the rated condition. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 8 条
  • [1] Numerical study and optimization of the combined indirect evaporative air cooler for air-conditioning systems
    Anisimov, Sergey
    Pandelidis, Demis
    Danielewicz, Jan
    [J]. ENERGY, 2015, 80 : 452 - 464
  • [2] Effects of Acoustic Barriers and Crosswind on the Operating Performance of Evaporative Cooling Tower Groups
    Dang Chao
    Jia Li
    Yang Lixin
    [J]. JOURNAL OF THERMAL SCIENCE, 2016, 25 (06) : 532 - 541
  • [3] A numerical study on the mechanism and optimization of wind-break structures for indirect air-cooling towers
    Gu, Hongfang
    Wang, Haijun
    Gu, Yuqian
    Yao, Jianan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 108 : 43 - 49
  • [4] Theoretical Prediction With Numerical and Experimental Verification to Predict Crosswind Effects on the Performance of Cooling Towers
    Hooman, Kamel
    [J]. HEAT TRANSFER ENGINEERING, 2015, 36 (05) : 480 - 487
  • [5] Numerical Modelling of Natural Draft Wet-Cooling Towers
    Klimanek, Adam
    [J]. ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2013, 20 (01) : 61 - 109
  • [6] Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers
    Lu, Yuanshen
    Guan, Zhiqiang
    Gurgenci, Hal
    Hooman, Kamel
    He, Suoying
    Bharathan, Desikan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 91 : 238 - 248
  • [7] The influence of windbreak wall orientation on the cooling performance of small natural draft dry cooling towers
    Lu, Yuanshen
    Gurgenci, Hal
    Guan, Zhiqiang
    He, Suoying
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 : 1059 - 1069
  • [8] Investigation of the crosswind-influenced thermal performance of a natural draft counterflow cooling tower
    Mondal, Pranab Kumar
    Mukherjee, Sanchayan
    Kundu, Balaram
    Wongwises, Somchai
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 85 : 1049 - 1057