Influence of nail polish on pulse oximeter readings of oxygen saturation: a systematic review

被引:0
作者
Ballesteros-Pena, Sendoa [1 ,3 ]
Fernandez-Aedo, Lrrintzi [1 ]
Picon, Artzai [2 ]
Lorrio-Palomino, Sergio [3 ]
机构
[1] Univ Basque Country, Euskal Herriko Unibertsitatea, Dept Enfermeria 1, Leioa 48940, Spain
[2] Tecnalia, Bilbao, Spain
[3] Hosp Univ Basurto, Bilbao, Spain
来源
EMERGENCIAS | 2015年 / 27卷 / 05期
关键词
Oximetry; Nail and cuticle products; Blood gas monitoring; transcutaneous; Diagnostic error;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Nail polish has traditionally been assumed to absorb light emitted by pulse oximeters and to interfere with the detection and measurement of oxygenated hemoglobin. In a systematic review of the literature we aimed to assess the influence of nail polish on the measurement of oxygen saturation by pulse oximetly (SpO(2)). A search protocol for online databases (MEDLINE, Embase, Web of Science, Scopus, Cumulative Index to Nursing and Allied Health Literature, and IBECS [the Spanish health sciences index]) was established to find clinical trials or observational studies published between 1999 and February 2014, Twelve nonrandomized clinical trials were found. Ten were in healthy volunteers. One of the remaining 2 studies was in critical patients undergoing mechanical ventilation, and the other was in patients with stable chronic obstructive pulmonary disease. One study recreated the low oxygen level of high altitudes, while the others were done in normal atmospheric conditions. Differences between pulse oximeters and type of nail polish were found. Nail polish was associated with a statistically significant decrease in SpO(2) for at least 1 color in all but 2 studies. However, the differences were within the standard error (+/- 2.0%) of the pulse oximeters used. The authors of the studies all concluded that although nail polish might change SpO(2) readings significantly, the variations are not clinically significant.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 20 条
[1]   Enamel nail polish does not interfere with pulse oximetry among normoxic volunteers [J].
Brand T.M. ;
Brand M.E. ;
Jay G.D. .
Journal of Clinical Monitoring and Computing, 2002, 17 (02) :93-96
[2]   What is the effect of fingernail polish on pulse oximetry? [J].
Chan, MM ;
Chan, MM ;
Chan, ED .
CHEST, 2003, 123 (06) :2163-2164
[3]   Effect of nail polish and henna on oxygen saturation determined by pulse oximetry in healthy young adult females [J].
Cicek, Hatice Sutcu ;
Gumus, Seyfettin ;
Deniz, Omer ;
Yildiz, Safak ;
Acikel, Cengiz Han ;
Cakir, Erdinc ;
Tozkoparan, Ergun ;
Ucar, Ergun ;
Bilgic, Hayati .
EMERGENCY MEDICINE JOURNAL, 2011, 28 (09) :783-785
[4]  
COTE CJ, 1988, ANESTH ANALG, V67, P683
[5]   Evaluation of pulse oximetry measurements in healthy subjects with nail polish [J].
Diccini, Solange ;
Pereira, Elizabete Mitsue ;
Im, Sonia Yoo ;
Shida, Lie Yamaguti ;
de Cassia Bettencourt, Ana Rita .
ACTA PAULISTA DE ENFERMAGEM, 2011, 24 (06) :784-788
[6]   Artificial acrylic finger nails may alter pulse oximetry measurement [J].
Hinkelbein, Jochen ;
Koehler, Heike ;
Genzwuerker, Harald V. ;
Fiedler, Fritz .
RESUSCITATION, 2007, 74 (01) :75-82
[7]   Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients [J].
Hinkelbein, Jochen ;
Genzwuerker, Harald V. ;
Sogl, Reiner ;
Fiedler, Fritz .
RESUSCITATION, 2007, 72 (01) :82-91
[8]  
Jakpor O, 2011, YOUNG SCI J, V4, P33
[9]  
JOVELL AJ, 1995, MED CLIN-BARCELONA, V105, P740
[10]   NAIL POLISH DOES NOT AFFECT PULSE OXIMETER SATURATION [J].
KATARIA, BK ;
LAMPKINS, R .
ANESTHESIA AND ANALGESIA, 1986, 65 (07) :824-824