Misfit and microleakage of implant-supported crown copings obtained by laser sintering and casting techniques, luted with glass-ionomer, resin cements and acrylic/urethane-based agents

被引:37
作者
Castillo-Oyaguee, Raquel [1 ]
Lynch, Christopher D. [2 ]
Turrion, Andres S. [1 ]
Lopez-Lozano, Jose F. [1 ]
Torres-Lagares, Daniel [3 ]
Suarez-Garcia, Maria-Jesus [1 ]
机构
[1] Complutense Univ Madrid UCM, Dept Buccofacial Prostheses, Fac Odontol, Madrid 28040, Spain
[2] Univ Wales Coll Cardiff Sch Dent, Cardiff, S Glam, Wales
[3] Univ Seville, Dept Stomatol, Fac Odontol, E-41009 Seville, Spain
关键词
Cement-retained implant-supported prosthesis; Direct metal laser sintering; Vacuum casting; Luting cement; Glass-ionomer cement; Cement microleakage; UNDERGRADUATE DENTAL SCHOOLS; BOND STRENGTH; MARGINAL LEAKAGE; VERTICAL MISFIT; INTERNAL FIT; ALLOYS; FABRICATION; CR;
D O I
10.1016/j.jdent.2012.09.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the marginal misfit and microleakage of cement-retained implant-supported crown copings. Methods: Single crown structures were constructed with: (1) laser-sintered Co-Cr (LS); (2) vacuum-cast Co-Cr (CC) and (3) vacuum-cast Ni-Cr-Ti (CN). Samples of each alloy group were randomly luted in standard fashion onto machined titanium abutments using: (1) GC Fuji PLUS (FP); (2) Clearfil Esthetic Cement (CEC); (3) RelyX Unicem 2 Automix (RXU) and (4) DentoTemp (DT) (n = 15 each). After 60 days of water ageing, vertical discrepancy was SEM-measured and cement microleakage was scored using a digital microscope. Misfit data were subjected to two-way ANOVA and Student-Newman-Keuls multiple comparisons tests. Kruskal-Wallis and Dunn's tests were run for microleakage analysis (a = 0.05). Results: Regardless of the cement type, LS samples exhibited the best fit, whilst CC and CN performed equally well. Despite the framework alloy and manufacturing technique, FP and DT provide comparably better fit and greater microleakage scores than did CEC and RXU, which showed no differences. Conclusions: DMLS of Co-Cr may be a reliable alternative to the casting of base metal alloys to obtain well-fitted implant-supported crowns, although all the groups tested were within the clinically acceptable range of vertical discrepancy. No strong correlations were found between misfit and microleakage. Notwithstanding the framework alloy, definitive resin-modified glass-ionomer (FP) and temporary acrylic/urethane-based (DT) cements demonstrated comparably better marginal fit and greater microleakage scores than did 10-methacryloxydecyl-dihydrogen phosphate-based (CEC) and self-adhesive (RXU) dual-cure resin agents. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 38 条
[1]   The teaching of implant dentistry in undergraduate dental schools in the United Kingdom and Ireland [J].
Addy, L. D. ;
Lynch, C. D. ;
Locke, M. ;
Watts, A. ;
Gilmour, A. S. M. .
BRITISH DENTAL JOURNAL, 2008, 205 (11) :609-614
[2]   Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain [J].
Akova, Tolga ;
Ucar, Yurdanur ;
Tukay, Alper ;
Balkaya, Mehmet Cudi ;
Brantley, William A. .
DENTAL MATERIALS, 2008, 24 (10) :1400-1404
[3]   Ready for practice? A study of confidence levels of final year dental students at Cardiff University and University College Cork [J].
不详 .
EUROPEAN JOURNAL OF DENTAL EDUCATION, 2011, 15 (02) :98-103
[4]  
Anusavice K. J., 2003, PHILLIPSSCIENCE DENT, V11th
[5]   Comparison of the effect of storage media on shear punch strength of resin luting cements [J].
Bagheri, Rafat ;
Mese, Ayse ;
Burrow, Michael F. ;
Tyas, Martin J. .
JOURNAL OF DENTISTRY, 2010, 38 (10) :820-827
[6]   Castability and resistance of ceramometal bonding in Ni-Cr and Ni-Cr-Be alloys [J].
Bezzon, OL ;
Ribeiro, RF ;
Rollo, JMDA ;
Crosara, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (03) :299-304
[7]  
Bottino MA, 2007, QUINTESSENCE INT, V38, pE425
[8]  
Calderini A, 2007, INT J ORAL MAX IMPL, V22, P831
[9]   Effect of water aging on microtensile bond strength of dual-cured resin cements to pre-treated sintered zirconium-oxide ceramics [J].
Castillo Oyague, Raquel ;
Monticelli, Francesca ;
Toledano, Manuel ;
Osorio, Estrella ;
Ferrari, Marco ;
Osorio, Raquel .
DENTAL MATERIALS, 2009, 25 (03) :392-399
[10]   Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques [J].
Castillo Oyaguee, Raquel ;
Sanchez-Turrion, Andres ;
Francisco Lopez-Lozano, Jose ;
Montero, Javier ;
Albaladejo, Alberto ;
Jesus Suarez-Garcia, Maria .
ODONTOLOGY, 2012, 100 (02) :249-253