Development and validation of reversed phase liquid chromatographic method utilizing ultraviolet detection for quantification of irinotecan (CPT-11) and its active metabolite, SN-38, in rat plasma and bile samples: Application to pharmacokinetic studies

被引:44
作者
Bansal, Tripta [1 ,2 ]
Awasthi, Anshumali [1 ]
Jaggi, Manu [1 ]
Khar, Roop K. [2 ]
Talegaonkar, Sushama [2 ]
机构
[1] Dabur Res Fdn, Ghaziabad 201010, Uttar Pradesh, India
[2] Jamia Hamdard, Fac Pharm, Dept Pharmaceut, New Delhi 110062, India
关键词
irinotecan (CPT-11); SN-38; plasma; bile; ultraviolet detection; pharmacokinetics;
D O I
10.1016/j.talanta.2008.04.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple. sensitive and specific reversed-phase high performance liquid chromatographic (HPLC) method using ultraviolet detection was developed and validated for the analysis of CPT-11 (lambda(max) = 254 nm, 365 nm) and its major active metabolite, SN-38 (lambda(max) = 380 nm) in rat plasma and bile. The sample pretreatment from plasma involved a single protein precipitation step with cold acetonitrile. In case of bile, liquid-liquid extraction with dichloromethane: tert-butyl methyl ether (3:7) was carried out. Topotecan, a structurally related camptothecin, was used as an internal standard. An aliquot of 50 mu L was injected onto a C-18 column. The chromatographic separation was achieved by gradient elution consisting of acetonitrile and water (pH 3.0 adjusted with 20% o-phosphoric acid) at a flow rate of 1.0 ml/min. Total run time for each sample was 30 min. All the analytes viz. topotecan. CPT-11, SN-38 were well separated with retention times of 11.4. 13.4 and 15.5 min, respectively. Method was found to be selective, linear (R-2 approximate to 0.999), accurate (recovery +/- 15%) and precise (<5% C.V.) in the selected concentration ranges for both the analytes. The quantification limit for CPT-11 was 40 ng ml(-1) and for SN-38 was 25 ng ml(-1). The percent extraction efficiency was similar to 97% for CPT-11 and SN-38 from plasma while extraction recovery of CPT-11 and SN-38 from bile was similar to 70% and similar to 60%, respectively. The method was successfully used to determine plasma and biliary excretion time profiles of CPT-11 and SN-38, following oral and intravenous CPT-11 administration in rats. In the present study, irinotecan showed an absolute bioavailability of 30% as calculated from the pharmacokinetic data. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1015 / 1021
页数:7
相关论文
共 20 条
  • [1] Concurrent determination of topotecan and model permeability markers (atenolol, antipyrine, propranolol and furosemide) by reversed phase liquid chromatography: Utility in Caco-2 intestinal absorption studies
    Bansal, Tripta
    Singh, Manoj
    Mishra, Gautam
    Talegaonkar, Sushama
    Khar, Roop K.
    Jaggi, Manu
    Mukherjee, Rama
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (02): : 261 - 266
  • [2] Simultaneous determination of the lactone and carboxylate forms of the camptothecin derivative CPT-11 and its metabolite SN-38 in plasma by high-performance liquid chromatography
    Chollet, DF
    Goumaz, L
    Renard, A
    Montay, G
    Vernillet, L
    Arnera, V
    Mazzo, DJ
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (01): : 163 - 175
  • [3] Chu XY, 1997, J PHARMACOL EXP THER, V281, P304
  • [4] Determination of irinotecan (CPT-11) and SN-38 in human whole blood and red blood cells by liquid chromatography with fluorescence detection
    de Jong, FA
    Mathijssen, RHJ
    de Bruijn, P
    Loos, WJ
    Verweij, J
    Sparreboom, A
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02): : 383 - 388
  • [5] Determination of irinotecan (CPT-11) and its active metabolite SN-38 in human plasma by reversed-phase high-performance liquid chromatography with fluorescence detection
    deBruijn, P
    Verweij, J
    Loos, WJ
    Nooter, K
    Stoter, G
    Sparreboom, A
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 698 (1-2): : 277 - 285
  • [6] Simple and rapid determination of irinotecan and its metabolite SN-38 in plasma by high-performance liquid-chromatography:: application to clinical pharmacokinetic studies
    Escoriaza, J
    Aldaz, A
    Castellanos, C
    Calvo, E
    Giráldez, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 159 - 168
  • [7] Determination by liquid chromatography with fluorescence detection of total 7-ethyl-10-hydroxy-camptothecin (SN-38) in beagle dog plasma after intravenous administration of liposome-based SN-38 (LE-SN38)
    Guo, W
    Ahmad, A
    Khan, S
    Dahhani, F
    Wang, YF
    Ahmad, I
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 85 - 92
  • [8] Gupta E, 1996, CANCER RES, V56, P1309
  • [9] Kaneda N, 1997, BIOL PHARM BULL, V20, P815
  • [10] LOKIEC F, 1995, CANCER CHEMOTH PHARM, V36, P79