Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET

被引:12
作者
Alessio, Adam M. [1 ]
Bassingthwaighte, James B. [1 ,2 ]
Glenny, Robb [3 ,4 ,5 ]
Caldwell, James H. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biophys, Seattle, WA 98195 USA
关键词
Myocardial blood flow; cardiac PET; quantitative PET; dynamic imaging; NH3; N-13; AMMONIA; KINETIC-MODEL; PERFUSION; NITROGEN-13-AMMONIA; MICROSPHERES; HEART;
D O I
10.1007/s12350-012-9632-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed approach models both the temporal and the spatial gradients in uptake and retention along the capillary. We validated PET-derived flow estimates with microsphere studies in 19 (9 rest, 10 stress) studies in five dogs. The radiotracer, N-13-ammonia, was injected intravenously while microspheres were administered into the left atrium. A regional reduction in hyperemic flow was forced by an external occluder in five of the stress studies. The flow estimates from the axially distributed model were compared with estimates from conventional compartmental models. The mean difference between microspheres and the axially distributed blood flow estimates in each of the 17 segments was 0.03 mL/g/minute (95% CI [-0.05, 0.11]). The blood flow estimates were highly correlated with each regional microsphere value for the axially distributed model (y = 0.98x + 0.06 mL/g/minute; r = 0.74; P < .001), for the two-compartment (y = 0.64x + 0.34; r = 0.74; P < .001), and for three-compartment model (y = 0.69x + 0.54; r = 0.74; P < .001). The variance of the error of the estimates is higher with the axially distributed model than the compartmental models (1.7 [1.3, 2.1] times higher). The proposed axially distributed model provided accurate regional estimates of MBF. The axially distributed model estimated blood flow with more accuracy, but less precision, than the evaluated compartmental models.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
[41]   Utility of Dynamic Perfusion PET Using 13N-Ammonia in Diagnosis of Asymptomatic Recurrence of Fibrosarcoma [J].
Harisankar, Chidambaram Natrajan Balasubramanian ;
Mittal, Bhagwant Rai ;
Watts, Ankit ;
Bhattacharya, Anish ;
Sen, Ramesh .
CLINICAL NUCLEAR MEDICINE, 2011, 36 (02) :150-151
[42]   Towards reliable myocardial blood-oxygen-level-dependent (BOLD) CMR using late effects of regadenoson with simultaneous 13n-ammonia pet validation in a whole-body hybrid PET/MR system [J].
Hsin-Jung Yang ;
Damini Dey ;
Jane M Sykes ;
John Butler ;
Behzad Sharif ;
Debiao Li ;
Sotirios Tsaftaris ;
Piotr Slomka ;
Frank S Prato ;
Rohan Dharmakumar .
Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
[43]   N-11C-Methyl-Dopamine PET Imaging of Sympathetic Nerve Injury in a Swine Model of Acute Myocardial Ischemia: A Comparison with 13N-Ammonia PET [J].
Zhou, Weina ;
Wang, Xiangcheng ;
He, Yulin ;
Nie, Yongzhen ;
Zhang, Guojian ;
Wang, Cheng ;
Wang, Chunmei ;
Wang, Xuemei .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[44]   Cardiac studies in rats with 11C-acetate and PET:: A comparison with 13N-ammonia [J].
Bentourkia, M ;
Croteau, É ;
Langlois, R ;
Aliaga, A ;
Cadorette, J ;
Bénard, F ;
Lesur, O ;
Lecomte, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2322-2327
[45]   Quantitative evaluation of myocardial blood flow with [N-13]ammonia [J].
Hutchins, GD .
CARDIOLOGY, 1997, 88 (01) :106-115
[46]   Simultaneous 13N-Ammonia and gadolinium first-pass myocardial perfusion with quantitative hybrid PET-MR imaging: a phantom and clinical feasibility study [J].
Nazir, Muhummad Sohaib ;
Gould, Sarah-May ;
Milidonis, Xenios ;
Reyes, Eliana ;
Ismail, Tevfik F. ;
Neji, Radhouene ;
Roujol, Sebastien ;
O'Doherty, Jim ;
Xue, Hui ;
Barrington, Sally F. ;
Schaeffter, Tobias ;
Razavi, Reza ;
Marsden, Paul ;
Kellman, Peter ;
Plein, Sven ;
Chiribiri, Amedeo .
EUROPEAN JOURNAL OF HYBRID IMAGING, 2019, 3 (01)
[47]   Dynamic 13N-ammonia PET:: A new imaging method to diagnose hypopituitarism [J].
Zhang, XS ;
Yue, DC ;
Yang, AW .
JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (01) :44-47
[48]   Evaluation of the Novel Myocardial Perfusion Positron-Emission Tomography Tracer 18F-BMS-747158-02 Comparison to 13N-Ammonia and Validation With Microspheres in a Pig Model [J].
Nekolla, S. G. ;
Reder, S. ;
Saraste, A. ;
Higuchi, T. ;
Dzewas, G. ;
Preissel, A. ;
Huisman, M. ;
Poethko, T. ;
Schuster, T. ;
Yu, M. ;
Robinson, S. ;
Casebier, D. ;
Henke, J. ;
Wester, H. J. ;
Schwaiger, M. .
CIRCULATION, 2009, 119 (17) :2333-2342
[49]   First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET A Pilot Study [J].
Yamamoto, Atsushi ;
Nagao, Michinobu ;
Ando, Kiyoe ;
Nakao, Risako ;
Matsuo, Yuka ;
Sakai, Akiko ;
Momose, Mitsuru ;
Kaneko, Koichiro ;
Hagiwara, Nobuhisa ;
Sakai, Shuji .
INTERNATIONAL HEART JOURNAL, 2022, 63 (02) :202-209
[50]   Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging [J].
Nina Burkhard ;
Bernhard A. Herzog ;
Lars Husmann ;
Aju P. Pazhenkottil ;
Irene A. Burger ;
Ronny R. Buechel ;
Ines Valenta ;
Christophe A. Wyss ;
Philipp A. Kaufmann .
European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 :517-521