Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET

被引:12
作者
Alessio, Adam M. [1 ]
Bassingthwaighte, James B. [1 ,2 ]
Glenny, Robb [3 ,4 ,5 ]
Caldwell, James H. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biophys, Seattle, WA 98195 USA
关键词
Myocardial blood flow; cardiac PET; quantitative PET; dynamic imaging; NH3; N-13; AMMONIA; KINETIC-MODEL; PERFUSION; NITROGEN-13-AMMONIA; MICROSPHERES; HEART;
D O I
10.1007/s12350-012-9632-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed approach models both the temporal and the spatial gradients in uptake and retention along the capillary. We validated PET-derived flow estimates with microsphere studies in 19 (9 rest, 10 stress) studies in five dogs. The radiotracer, N-13-ammonia, was injected intravenously while microspheres were administered into the left atrium. A regional reduction in hyperemic flow was forced by an external occluder in five of the stress studies. The flow estimates from the axially distributed model were compared with estimates from conventional compartmental models. The mean difference between microspheres and the axially distributed blood flow estimates in each of the 17 segments was 0.03 mL/g/minute (95% CI [-0.05, 0.11]). The blood flow estimates were highly correlated with each regional microsphere value for the axially distributed model (y = 0.98x + 0.06 mL/g/minute; r = 0.74; P < .001), for the two-compartment (y = 0.64x + 0.34; r = 0.74; P < .001), and for three-compartment model (y = 0.69x + 0.54; r = 0.74; P < .001). The variance of the error of the estimates is higher with the axially distributed model than the compartmental models (1.7 [1.3, 2.1] times higher). The proposed axially distributed model provided accurate regional estimates of MBF. The axially distributed model estimated blood flow with more accuracy, but less precision, than the evaluated compartmental models.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
[11]   Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET [J].
El Fakhri, Georges ;
Kardan, Arash ;
Sitek, Arkadiusz ;
Dorbala, Sharmila ;
Abi-Hatem, Nathalie ;
Lahoud, Youmna ;
Fischman, Alan ;
Coughlan, Martha ;
Yasuda, Tsunehiro ;
Di Carli, Marcelo F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (07) :1062-1071
[12]   Characterizing the normal range of myocardial blood flow with 82rubidium and 13N-ammonia PET imaging [J].
Jennifer M. Renaud ;
Jean N. DaSilva ;
Rob S. B. Beanlands ;
Robert A. deKemp .
Journal of Nuclear Cardiology, 2013, 20 :578-591
[13]   Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve [J].
Fiechter, Michael ;
Ghadri, Jelena R. ;
Gebhard, Catherine ;
Fuchs, Tobias A. ;
Pazhenkottil, Aju P. ;
Nkoulou, Rene N. ;
Herzog, Bernhard A. ;
Wyss, Christophe A. ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) :1230-1234
[14]   13N-ammonia PET/CT stress myocardial blood flow compared to fractional flow reserve in coronary artery disease [J].
Boer, Jouke J. ;
Kappelhof, Johan J. J. S. ;
van der Zant, Friso M. ;
Wondergem, Maurits ;
de Swart, Hans J. B. R. M. ;
Knol, Remco J. J. .
NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (02) :133-138
[15]   Regadenoson-induced hyperemia for absolute myocardial blood flow quantitation by 13N-ammonia PET and detection of cardiac allograft vasculopathy [J].
Packard, Rene R. Sevag ;
Maddahi, Jamshid .
JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) :1145-1148
[16]   Radiation exposure to the personnel performing myocardial blood flow quantification study using 13N-ammonia positron emission tomography/computed tomography [J].
Rana, Nivedita ;
Srivastava, Ashish ;
Kumar, Munish ;
Parmar, Madan ;
Kumar, Rajender ;
Mittal, Bhagwant .
INDIAN JOURNAL OF NUCLEAR MEDICINE, 2023, 38 (04) :362-365
[17]   13N-Ammonia myocardial blood flow quantitation in patient with aneurismal coronary artery disease [J].
Plata-Corona, Juan Carlos ;
Carvajal-Juarez, Isabel ;
Espinola-Zavaleta, Nilda ;
de los Santos, Felix Damas ;
Rivera-Bravo, Belen ;
Alexanderson-Rosas, Erick .
JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (04) :1826-1831
[18]   Comparison between the summed difference score and myocardial blood flow measured by 13N-ammonia [J].
Giubbini, Raffaele ;
Peli, Alessia ;
Milan, Elisa ;
Sciagra, Roberto ;
Camoni, Luca ;
Albano, Domenico ;
Bertoli, Mattia ;
Bonacina, Mattia ;
Motta, Federica ;
Statuto, Massimo ;
Rodella, Carlo Alberto ;
De Agostini, Antonio ;
Calabretta, Raffaella ;
Bertagna, Francesco .
JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (05) :1621-1628
[19]   Uniformity and repeatability of normal resting myocardial blood flow in rats using [13N]-ammonia and small animal PET [J].
Lamoureux, Marc ;
Thorn, Stephanie ;
Dumouchel, Tyler ;
Renaud, Jennifer M. ;
Klein, Ran ;
Mason, Samantha ;
Lortie, Mireille ;
DaSilva, Jean N. ;
Beanlands, Rob S. ;
deKemp, Robert A. .
NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (09) :917-925
[20]   Myocardial ischaemia in patients with primary APS:: a 13N-ammonia PET assessment [J].
Alexanderson, E. ;
Gomez-Leon, A. ;
Vargas, A. ;
Romero, J. L. ;
Fernandez, C. Sierra ;
Valero, M. Rodriguez ;
Garcia-Rojas, L. ;
Meave, A. ;
Amigo, M. -C. .
RHEUMATOLOGY, 2008, 47 (06) :894-896