Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET

被引:12
|
作者
Alessio, Adam M. [1 ]
Bassingthwaighte, James B. [1 ,2 ]
Glenny, Robb [3 ,4 ,5 ]
Caldwell, James H. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Biophys, Seattle, WA 98195 USA
关键词
Myocardial blood flow; cardiac PET; quantitative PET; dynamic imaging; NH3; N-13; AMMONIA; KINETIC-MODEL; PERFUSION; NITROGEN-13-AMMONIA; MICROSPHERES; HEART;
D O I
10.1007/s12350-012-9632-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimation of myocardial blood flow (MBF) with cardiac PET is often performed with conventional compartmental models. In this study, we developed and evaluated a physiologically and anatomically realistic axially distributed model. Unlike compartmental models, this axially distributed approach models both the temporal and the spatial gradients in uptake and retention along the capillary. We validated PET-derived flow estimates with microsphere studies in 19 (9 rest, 10 stress) studies in five dogs. The radiotracer, N-13-ammonia, was injected intravenously while microspheres were administered into the left atrium. A regional reduction in hyperemic flow was forced by an external occluder in five of the stress studies. The flow estimates from the axially distributed model were compared with estimates from conventional compartmental models. The mean difference between microspheres and the axially distributed blood flow estimates in each of the 17 segments was 0.03 mL/g/minute (95% CI [-0.05, 0.11]). The blood flow estimates were highly correlated with each regional microsphere value for the axially distributed model (y = 0.98x + 0.06 mL/g/minute; r = 0.74; P < .001), for the two-compartment (y = 0.64x + 0.34; r = 0.74; P < .001), and for three-compartment model (y = 0.69x + 0.54; r = 0.74; P < .001). The variance of the error of the estimates is higher with the axially distributed model than the compartmental models (1.7 [1.3, 2.1] times higher). The proposed axially distributed model provided accurate regional estimates of MBF. The axially distributed model estimated blood flow with more accuracy, but less precision, than the evaluated compartmental models.
引用
收藏
页码:64 / 75
页数:12
相关论文
共 50 条
  • [11] Simplified quantification of 13N-ammonia PET myocardial blood flow: A comparative study with the standard compartment model to facilitate clinical use
    Chih-Yung Chang
    Guang-Uei Hung
    Bailing Hsu
    Bang-Hung Yang
    Chi-Wei Chang
    Lien-Hsin Hu
    Wen-Sheng Huang
    Hsin-Ell Wang
    Tao-Cheng Wu
    Ren-Shyan Liu
    Journal of Nuclear Cardiology, 2020, 27 : 819 - 828
  • [12] Simplified quantification of 13N-ammonia PET myocardial blood flow: A comparative study with the standard compartment model to facilitate clinical use
    Chang, Chih-Yung
    Hung, Guang-Uei
    Hsu, Bailing
    Yang, Bang-Hung
    Chang, Chi-Wei
    Hu, Lien-Hsin
    Huang, Wen-Sheng
    Wang, Hsin-Ell
    Wu, Tao-Cheng
    Liu, Ren-Shyan
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (03) : 819 - 828
  • [13] Software reproducibility of myocardial blood flow and flow reserve quantification in ischemic heart disease: A 13N-ammonia PET study
    Monroy-Gonzalez, Andrea G.
    Juarez-Orozco, Luis Eduardo
    Han, Chunlei
    Vedder, Issi R.
    Garcia, David Vallez
    Borra, Ronald
    Slomka, Piotr J.
    Nesterov, Sergey V.
    Knuuti, Juhani
    Slart, Riemer H. J. A.
    Alexanderson-Rosas, Erick
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (04) : 1225 - 1233
  • [14] Myocardial blood flow estimation with 13N-ammonia PET/CT: influence of reconstruction settings
    Gallo, L.
    Ferretti, A.
    Bolla, E.
    Milan, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S326 - S326
  • [15] Human 13N-ammonia PET studies: the importance of measuring 13N-ammonia metabolites in blood
    Keiding, Susanne
    Sorensen, Michael
    Munk, Ole Lajord
    Bender, Dirk
    METABOLIC BRAIN DISEASE, 2010, 25 (01) : 49 - 56
  • [16] Quantitative analysis of myocardial blood flow response to regadenoson and adenosine using 13N-ammonia perfusion PET.
    Weinberg, Richard
    Castano, Adam
    Panagiotou, Demetrios
    Kinkhabwala, Mona
    Bhatia, Ketan
    Morgenstern, Rachelle
    DeLuca, Albert
    Bokhari, Sabahat
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [17] Human 13N-ammonia PET studies: the importance of measuring 13N-ammonia metabolites in blood
    Susanne Keiding
    Michael Sørensen
    Ole Lajord Munk
    Dirk Bender
    Metabolic Brain Disease, 2010, 25 : 49 - 56
  • [18] VALIDATION OF NITROGEN-13-AMMONIA TRACER KINETIC-MODEL FOR QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW USING PET
    MUZIK, O
    BEANLANDS, RSB
    HUTCHINS, GD
    MANGNER, TJ
    NGUYEN, N
    SCHWAIGER, M
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (01) : 83 - 91
  • [19] Quantifying the normal range of myocardial blood flow with 13N-ammonia PET and tracer kinetic modeling
    Renaud, Jennifer M.
    Lortie, Mireille
    Wassenaar, Richard W.
    DaSilva, Jean
    Beanlands, Robert S.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1686 - 1690
  • [20] Acquisition of dynamic N-13 ammonia PET for myocardial blood flow quantification
    Kang, Kyeong Won
    Kim, Jong Sang
    Cho, Sang-Geon
    Kim, Jahae
    Song, Ho-Chun
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (04) : 1288 - 1292