Assessment of the Speech Intelligibility Performance of Post Lingual Cochlear Implant Users at Different Signal-to-Noise Ratios Using the Turkish Matrix Test

被引:3
|
作者
Polat, Zahra [1 ]
Bulut, Erdogan [2 ]
Atas, Ahmet [3 ]
机构
[1] Istanbul Univ, Sch Med, Dept Audiol, Istanbul, Turkey
[2] Trakya Univ, Sch Med, Dept Audiol, Istanbul, Turkey
[3] Cerrahpasa Med Sch Hosp, Dept Otorhinolaryngol, Istanbul, Turkey
关键词
Turkish Matrix Test; noise; speech intelligibility; cochlear implant; SENTENCE TEST;
D O I
10.5152/balkanmedj.2016.160180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Spoken word recognition and speech perception tests in quiet are being used as a routine in assessment of the benefit which children and adult cochlear implant users receive from their devices. Cochlear implant users generally demonstrate high level performances in these test materials as they are able to achieve high level speech perception ability in quiet situations. Although these test materials provide valuable information regarding Cochlear Implant (CI) users' performances in optimal listening conditions, they do not give realistic information regarding performances in adverse listening conditions, which is the case in the everyday environment. Aims: The aim of this study was to assess the speech intelligibility performance of post lingual CI users in the presence of noise at different signal-to-noise ratio with the Matrix Test developed for Turkish language. Study Design: Cross-sectional study. Methods: The thirty post lingual implant user adult subjects, who had been using implants for a minimum of one year, were evaluated with Turkish Matrix test. Subjects' speech intelligibility was measured using the adaptive and non-adaptive Matrix Test in quiet and noisy environments. Results: The results of the study show a correlation between Pure Tone Average (PTA) values of the subjects and Matrix test Speech Reception Threshold (SRT) values in the quiet. Hence, it is possible to asses PTA values of CI users using the Matrix Test also. However, no correlations were found between Matrix SRT values in the quiet and Matrix SRT values in noise. Similarly, the correlation between PTA values and intelligibility scores in noise was also not significant. Therefore, it may not be possible to assess the intelligibility performance of CI users using test batteries performed in quiet conditions. Conclusion: The Matrix Test can be used to assess the benefit of CI users from their systems in everyday life, since it is possible to perform intelligibility test with the Matrix test using a material that CI users experience in their everyday life and it is possible to assess their difficulty in speech discrimination in noisy conditions they have to cope with.
引用
收藏
页码:532 / 538
页数:7
相关论文
共 12 条
  • [1] Speech intelligibility and recall of first and second language words heard at different signal-to-noise ratios
    Hygge, Staffan
    Kjellberg, Anders
    Nostl, Anatole
    FRONTIERS IN PSYCHOLOGY, 2015, 6
  • [2] Comparing the Speech Perception of Cochlear Implant Users with Three Different Finnish Speech Intelligibility Tests in Noise
    Willberg, Tytti
    Sivonen, Ville
    Linder, Pia
    Dietz, Aarno
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)
  • [3] Music perception and speech intelligibility in noise performance by Italian-speaking cochlear implant users
    Hilal Dincer D’Alessandro
    Patrick J. Boyle
    Ginevra Portanova
    Patrizia Mancini
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 3821 - 3829
  • [4] Music perception and speech intelligibility in noise performance by Italian-speaking cochlear implant users
    Dincer D'Alessandro, Hilal
    Boyle, Patrick J.
    Portanova, Ginevra
    Mancini, Patrizia
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (08) : 3821 - 3829
  • [5] Subjective Assessment of Cochlear Implant Users' Signal-to-Noise Ratio Requirements for Different Levels of Wireless Device Usability
    Julstrom, Stephen
    Kozma-Spytek, Linda
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2014, 25 (10) : 952 - 968
  • [6] The signal-to-noise ratio assessment in cochlear implanted patients through the Italian Matrix Sentence test (Oldenburg test)
    Gallo, Samanta
    Castiglione, Alessandro
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (02) : 145 - 148
  • [7] Speech Intelligibility and Spatial Release From Masking Improvements Using Spatial Noise Reduction Algorithms in Bimodal Cochlear Implant Users
    Zedan, Ayham
    Juergens, Tim
    Williges, Ben
    Kollmeier, Birger
    Wiebe, Konstantin
    Galindo, Julio
    Wesarg, Thomas
    TRENDS IN HEARING, 2021, 25
  • [8] Listening efficiency in adult cochlear-implant users compared with normally-hearing controls at ecologically relevant signal-to-noise ratios
    Perez, Francisca Perea
    Hartley, Douglas E. H.
    Kitterick, Padraig T.
    Zekveld, Adriana A. A.
    Naylor, Graham
    Wiggins, Ian M. M.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2023, 17
  • [9] Listening Effort Measured With Pupillometry in Cochlear Implant Users Depends on Sound Level, But Not on the Signal to Noise Ratio When Using the Matrix Test
    Stronks, Hendrik Christiaan
    Tops, Annemijn Laura
    Quach, Kwong Wing
    Briaire, Jeroen Johannes
    Frijns, Johan Hubertus Maria
    EAR AND HEARING, 2024, 45 (06) : 1461 - 1473
  • [10] Relationship Between the Ability to Detect Frequency Changes or Temporal Gaps and Speech Perception Performance in Post-lingual Cochlear Implant Users
    Xie, Dianzhao
    Luo, Jianfen
    Chao, Xiuhua
    Li, Jinming
    Liu, Xianqi
    Fan, Zhaomin
    Wang, Haibo
    Xu, Lei
    FRONTIERS IN NEUROSCIENCE, 2022, 16