Ultra-performance liquid chromatography tandem mass-spectrometry (UPLC-MS/MS) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

被引:78
作者
Hampel, Daniela [1 ]
York, Emily R. [1 ,2 ]
Allen, Lindsay H. [1 ]
机构
[1] USDA ARS, Western Human Nutr Res Ctr, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 903卷
关键词
B-vitamins; Human milk; Infant requirements; Lactation; UPLC-MS/MS; WATER-SOLUBLE VITAMINS; VITAMERS; FORMS; FOODS;
D O I
10.1016/j.jchromb.2012.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, rapid and sensitive ultra-performance liquid-chromatography tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin. Flavin adenine dinucleotide (FAD), nicotinamide and pyridoxal (PL) has been optimized within 2 min using a gradient of 10 mM ammonium formate (aq) and acetonitrile. Thiamin-(4-methyl-C-13-thiazol-5-yl-C-13(3)) hydrochloride, riboflavin-dioxo-pyrimidine-C-13(4),N-15(2), and pyridoxal-methyl-d(3) hydrochloride were used as internal standards. A sample-like matrix was found to be mandatory for the external standard curve preparation. C-13(3)-caffeine was added for direct assessment of analyte recovery. Intra- and inter-assay variability for all analytes ranged from 0.4 to 7.9% and from 2.2 to 5.2%, respectively. Samples were subjected to protein precipitation and removal of non-polar constituents by diethyl ether prior to analysis. Quantification was done by ratio response to the stable isotope labeled internal standards. The standard addition method determined recovery rates for each vitamin (73.0-100.2%). The limit of quantitation for all vitamins was between 0.05 and 5 ppb depending on the vitamin. Alternative approaches for sample preparation such as protein removal by centrifugal filter units, acetonitrile or trichloroacetic acid revealed low recovery and a greater coefficient of variation. Matrix effect studies indicated a significant influence by matrix constituents, showing the importance of stable isotope labeled internal standards for analyte quantitation in complex matrices. Published by Elsevier B.V.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 34 条
  • [11] Deconinck E., 2010, J PHARM BIOMED ANAL, V54, P995
  • [12] Eitenmiller R.R., 1999, VITAMIN ANAL HLTH FO
  • [13] Properties of human milk and their relationship with maternal nutrition
    Emmett, PM
    Rogers, IS
    [J]. EARLY HUMAN DEVELOPMENT, 1997, 49 : S7 - S28
  • [14] COMPARISON OF THE VITAMIN-B COMPOSITION OF MILK FROM MOTHERS OF PRETERM AND TERM BABIES
    FORD, JE
    ZECHALKO, A
    MURPHY, J
    BROOKE, OG
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1983, 58 (05) : 367 - 372
  • [15] Do breastfed infants need supplemental vitamins?
    Greer, FR
    [J]. PEDIATRIC CLINICS OF NORTH AMERICA, 2001, 48 (02) : 415 - +
  • [16] ANALYSIS OF B-6 VITAMERS IN HUMAN-MILK BY REVERSE-PHASE LIQUID-CHROMATOGRAPHY
    HAMAKER, B
    KIRKSEY, A
    EKANAYAKE, A
    BORSCHEL, M
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 42 (04) : 650 - 655
  • [17] The determination of free and phosphorylated thiamin by a modified thiochrome assay
    Hennessy, DJ
    Cerecedo, LR
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1939, 61 : 179 - 183
  • [18] Simultaneous determination of four water-soluble vitamins in fortified infant foods by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry
    Lu, Baiyi
    Ren, Yiping
    Huang, Baifen
    Liao, Wenqun
    Cai, Zengxuan
    Tie, Xiaowei
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (03) : 225 - 232
  • [19] Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    Matuszewski, BK
    Constanzer, ML
    Chavez-Eng, CM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3019 - 3030
  • [20] Novel generic UPLC/MS/MS method for high throughput analysis applied to permeability assessment in early Drug Discovery
    Mensch, Jurgen
    Noppe, Mark
    Adriaensen, Jef
    Melis, Anouche
    Mackie, Claire
    Augustijns, Patrick
    Brewster, Marcus E.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 847 (02): : 182 - 187