Ultra-performance liquid chromatography tandem mass-spectrometry (UPLC-MS/MS) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

被引:78
作者
Hampel, Daniela [1 ]
York, Emily R. [1 ,2 ]
Allen, Lindsay H. [1 ]
机构
[1] USDA ARS, Western Human Nutr Res Ctr, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 903卷
关键词
B-vitamins; Human milk; Infant requirements; Lactation; UPLC-MS/MS; WATER-SOLUBLE VITAMINS; VITAMERS; FORMS; FOODS;
D O I
10.1016/j.jchromb.2012.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, rapid and sensitive ultra-performance liquid-chromatography tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin. Flavin adenine dinucleotide (FAD), nicotinamide and pyridoxal (PL) has been optimized within 2 min using a gradient of 10 mM ammonium formate (aq) and acetonitrile. Thiamin-(4-methyl-C-13-thiazol-5-yl-C-13(3)) hydrochloride, riboflavin-dioxo-pyrimidine-C-13(4),N-15(2), and pyridoxal-methyl-d(3) hydrochloride were used as internal standards. A sample-like matrix was found to be mandatory for the external standard curve preparation. C-13(3)-caffeine was added for direct assessment of analyte recovery. Intra- and inter-assay variability for all analytes ranged from 0.4 to 7.9% and from 2.2 to 5.2%, respectively. Samples were subjected to protein precipitation and removal of non-polar constituents by diethyl ether prior to analysis. Quantification was done by ratio response to the stable isotope labeled internal standards. The standard addition method determined recovery rates for each vitamin (73.0-100.2%). The limit of quantitation for all vitamins was between 0.05 and 5 ppb depending on the vitamin. Alternative approaches for sample preparation such as protein removal by centrifugal filter units, acetonitrile or trichloroacetic acid revealed low recovery and a greater coefficient of variation. Matrix effect studies indicated a significant influence by matrix constituents, showing the importance of stable isotope labeled internal standards for analyte quantitation in complex matrices. Published by Elsevier B.V.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 34 条
  • [1] Allen L H, 1994, SCN News, P21
  • [2] [Anonymous], 1998, DIET REF INT THIAM R
  • [3] RIBOFLAVIN STATUS IN INFANTS BORN IN RURAL GAMBIA, AND THE EFFECT OF A WEANING FOOD SUPPLEMENT
    BATES, CJ
    PRENTICE, AM
    PAUL, AA
    PRENTICE, A
    SUTCLIFFE, BA
    WHITEHEAD, RG
    [J]. TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1982, 76 (02) : 253 - 258
  • [4] Analysis of ecologically relevant pharmaceuticals in wastewater and surface water using selective solid-phase extraction and UPLC-MS/MS
    Batt, Angela L.
    Kostich, Mitch S.
    Lazorchak, James M.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (13) : 5021 - 5030
  • [5] BELITZ H.D., 1992, Lehrbuch der Lebensmittelchemie, V4th
  • [6] Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS
    Berg, Thomas
    Lundanes, Elsa
    Christophersen, Asbjorg S.
    Strand, Dag Helge
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (04): : 421 - 432
  • [7] EFFECTS OF VITAMIN-B6 INTAKE ON NUTRITURE AND GROWTH OF YOUNG INFANTS
    BORSCHEL, MW
    KIRKSEY, A
    HANNEMANN, RE
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 43 (01) : 7 - 15
  • [8] Folate analysis in foods by UPLC-MS/MS: development and validation of a novel, high throughput quantitative assay; folate levels determined in Australian fortified breads
    Chandra-Hioe, Maria V.
    Bucknall, Martin P.
    Arcot, Jayashree
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (03) : 1035 - 1042
  • [9] Improving LC-MS sensitivity through increases in chromatographic performance: Comparisons of UPLC-ES/MS/MS to HPLC-ES/MS/MS
    Churchwell, MI
    Twaddle, NC
    Meeker, LR
    Doerge, DR
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02): : 134 - 143
  • [10] Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the sensitive determination of folates in rice
    De Brouwer, Veerle
    Storozhenko, Sergei
    Stove, Christophe P.
    Van Daele, Jeroen
    Van Der Straeten, Dominique
    Lambert, Willy E.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (3-4): : 509 - 513