Comparison of Enterprise With Neuroform Stent-Assisted Coiling of Intracranial Aneurysms

被引:59
|
作者
Kadkhodayan, Yasha [1 ]
Rhodes, Nicholas [1 ]
Blackburn, Spiros [2 ]
Derdeyn, Colin P. [1 ,3 ,4 ]
Cross, DeWitte T., III [1 ,3 ]
Moran, Christopher J. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Intervent Neuroradiol Sect, Mallinckrodt Inst Radiol, St Louis, MO USA
[2] Univ Florida, Dept Neurosurg, Gainesville, FL USA
[3] Washington Univ, Dept Neurol Surg, Sch Med, St Louis, MO USA
[4] Washington Univ, Sch Med, Dept Neurol, St Louis, MO 63110 USA
关键词
Enterprise stent; intracranial aneurysm; Neuroform stent; stent-assisted coil embolization; EXPANDING NITINOL STENT; CEREBRAL ANEURYSMS; ARTERY; APPOSITION; PLACEMENT; EMBOLIZATION; SIZE;
D O I
10.2214/AJR.12.8954
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. SUBJECTS AND METHODS. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. RESULTS. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p < 0.0001). There were no significant differences in the rates of stent movement, misplacement, or symptomatic hemorrhage. Symptomatic thromboembolic events, however, were more frequent with the Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). CONCLUSION. Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.
引用
收藏
页码:872 / 878
页数:7
相关论文
共 50 条
  • [41] Stent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial
    Boisseau, W.
    Darsaut, T. E.
    Fahed, R.
    Drake, B.
    Lesiuk, H.
    Rempel, J. L.
    Gentric, J. -c.
    Ognard, J.
    Nico, L.
    Iancu, D.
    Roy, D.
    Weill, A.
    Chagnon, M.
    Zehr, J.
    Lavoie, P.
    Nguyen, T. N.
    Raymond, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (04) : 381 - 389
  • [42] Endovascular Enterprise stent-assisted coil embolization for wide-necked unruptured intracranial aneurysms
    Hwang, Sung-Kyun
    Hwang, Gyojun
    Bang, Jae Seung
    Oh, Chang Wan
    Kwon, O-Ki
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (09) : 1276 - 1279
  • [43] Stent-assisted coiling of unruptured intracranial aneurysms: Long-term follow-up in 164 patients with 183 aneurysms
    Mine, Benjamin
    Aljishi, Ali
    D'Harcour, Jean-Bernard
    Brisbois, Denis
    Collignon, Laurent
    Lubicz, Boris
    JOURNAL OF NEURORADIOLOGY, 2014, 41 (05) : 322 - 328
  • [44] Enterprise stents versus low-profile visualized intraluminal support stents for stent-assisted coiling of unruptured paraclinoid aneurysms
    Wu, Zhi-Ping
    Yin, Jian-Lin
    Liu, Shan-Kai
    Ji, Song
    Liu, Jian-Yu
    Wang, Hai-Lan
    Zhang, Yi-Sheng
    Zhang, Da-Zhong
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (05) : 1855 - 1865
  • [45] Stent-assisted coiling using the Neuroform Atlas stent for treatment of aneurysms that recur after coil embolization
    Dong, Linggen
    Wang, Jiejun
    Chen, Xiheng
    Zhang, Longhui
    Zhao, Zhiqiang
    Peng, Qichen
    Jin, Zeping
    Wu, Jun
    Lv, Ming
    Liu, Peng
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [46] Stent-Assisted Coiling of Intracranial Aneurysms Using a Nitinol-Based Stent (Neuroform Atlas): A Systematic Review and Meta-analysis
    Pranata, Raymond
    Yonas, Emir
    Deka, Hadrian
    Vania, Rachel
    July, Julius
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (07) : 1049 - 1061
  • [47] The safety and efficacy of low-dosage tirofiban for stent-assisted coiling of ruptured intracranial aneurysms
    Yan, Yazhou
    He, Xiaowu
    Fang, Yibin
    Xu, Yi
    Hong, Bo
    Liu, Jianmin
    Huang, Qinghai
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 2211 - 2218
  • [48] Comparison of Stent-Assisted Coiling and Balloon-Assisted Coiling in the Treatment of Ruptured Wide-Necked Intracranial Aneurysms in the Acute Period
    Cai, Kefu
    Zhang, Yunfeng
    Shen, Lihua
    Ni, Yaohui
    Ji, Qiuhong
    WORLD NEUROSURGERY, 2016, 96 : 316 - 321
  • [49] Stent-Assisted Coiling of Intracranial Aneurysms Using a Nitinol-Based Stent (Neuroform Atlas): A Systematic Review and Meta-analysis
    Raymond Pranata
    Emir Yonas
    Hadrian Deka
    Rachel Vania
    Julius July
    CardioVascular and Interventional Radiology, 2020, 43 : 1049 - 1061
  • [50] Endovascular Treatment of Large Intracranial Aneurysms by Neuroform Stent-Assisted Coil Placement
    Mu, Shiqing
    Yang, Xingjian
    Li, Youxiang
    Lv, Ming
    Wu, Zhongxue
    NEURORADIOLOGY JOURNAL, 2009, 22 (01) : 102 - 107