Comparison of Enterprise With Neuroform Stent-Assisted Coiling of Intracranial Aneurysms

被引:59
|
作者
Kadkhodayan, Yasha [1 ]
Rhodes, Nicholas [1 ]
Blackburn, Spiros [2 ]
Derdeyn, Colin P. [1 ,3 ,4 ]
Cross, DeWitte T., III [1 ,3 ]
Moran, Christopher J. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Intervent Neuroradiol Sect, Mallinckrodt Inst Radiol, St Louis, MO USA
[2] Univ Florida, Dept Neurosurg, Gainesville, FL USA
[3] Washington Univ, Dept Neurol Surg, Sch Med, St Louis, MO USA
[4] Washington Univ, Sch Med, Dept Neurol, St Louis, MO 63110 USA
关键词
Enterprise stent; intracranial aneurysm; Neuroform stent; stent-assisted coil embolization; EXPANDING NITINOL STENT; CEREBRAL ANEURYSMS; ARTERY; APPOSITION; PLACEMENT; EMBOLIZATION; SIZE;
D O I
10.2214/AJR.12.8954
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. SUBJECTS AND METHODS. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. RESULTS. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p < 0.0001). There were no significant differences in the rates of stent movement, misplacement, or symptomatic hemorrhage. Symptomatic thromboembolic events, however, were more frequent with the Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). CONCLUSION. Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.
引用
收藏
页码:872 / 878
页数:7
相关论文
共 50 条
  • [31] Safety and cost of stent-assisted coiling of unruptured intracranial aneurysms compared with coiling or clipping
    Frontera, Jennifer A.
    Moatti, Joseph
    de los Reyes, Kenneth M.
    McCullough, Stephen
    Moyle, Henry
    Bederson, Joshua B.
    Patel, Aman
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (01) : 65 - 71
  • [32] "Y" and "X" Stent-Assisted Coiling of Complex and Wide-Neck Intracranial Bifurcation Aneurysms
    Bartolini, B.
    Blanc, R.
    Pistocchi, S.
    Redjem, H.
    Piotin, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) : 2153 - 2158
  • [33] Transcirculation approach for stent-assisted coiling of intracranial aneurysms: a multicenter study
    Mascitelli, Justin R.
    Levitt, Michael R.
    Griessenauer, Christoph J.
    Kim, Louis J.
    Gross, Bradley
    Abla, Adib
    Winkler, Ethan
    Jankowitz, Brian
    Grandhi, Ramesh
    Goren, Oded
    Schirmer, Clemens M.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (08) : 711 - +
  • [34] Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients
    Sedat, Jacques
    Chau, Yves
    Gaudart, Jean
    Sachet, Marina
    Beuil, Stephanie
    Lonjon, Michel
    NEURORADIOLOGY, 2018, 60 (02) : 211 - 219
  • [35] Balloon Remodeling May Improve Angiographic Results of Stent-Assisted Coiling of Unruptured Intracranial Aneurysms
    Gentric, Jean-Christophe
    Biondi, Alessandra
    Piotin, Michel
    Mounayer, Charbel
    Lobotesis, Kyriakos
    Bonafe, Alain
    Costalat, Vincent
    NEUROSURGERY, 2015, 76 (04) : 441 - 445
  • [36] Comparison of Stent-Assisted Coiling vs Coiling Alone in 563 Intracranial Aneurysms: Safety and Efficacy at a High-Volume Center
    Yang, Hongchao
    Sun, Yong
    Jiang, Yuhua
    Lv, Xianli
    Zhao, Yang
    Li, Youxiang
    Liu, Aihua
    NEUROSURGERY, 2015, 77 (02) : 241 - 247
  • [37] Comparison of Stent-Assisted Coil Placement and Coiling-Only for the Treatment of Ruptured Intracranial Aneurysms
    Liu, Yongsheng
    Wang, Feng
    Wang, Mingyi
    Zhang, Guogdong
    MEDICAL SCIENCE MONITOR, 2017, 23 : 5697 - 5704
  • [38] Neuroform Stent-Assisted Coiling of Unruptured Intracranial Aneurysms: Short- and Midterm Results from a Single-Center Experience with 68 Patients
    Maldonado, I. L.
    Machi, P.
    Costalat, V.
    Mura, T.
    Bonafe, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 131 - 136
  • [39] Propensity score-adjusted analysis on stent-assisted coiling versus coiling alone for ruptured intracranial aneurysms
    Goertz, Lukas
    Liebig, Thomas
    Pennig, Lenhard
    Timmer, Marco
    Styczen, Hanna
    Grunz, Jan-Peter
    Lichtenstein, Thorsten
    Schlamann, Marc
    Kabbasch, Christoph
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] Stent-assisted coil embolization of intracranial aneurysms using Solitaire stent
    Zhang, Jingbo
    Lv, Xianli
    Yang, Jun
    Wu, Zhongxue
    NEUROLOGY INDIA, 2012, 60 (03) : 278 - 282