Comparison of Enterprise With Neuroform Stent-Assisted Coiling of Intracranial Aneurysms

被引:60
作者
Kadkhodayan, Yasha [1 ]
Rhodes, Nicholas [1 ]
Blackburn, Spiros [2 ]
Derdeyn, Colin P. [1 ,3 ,4 ]
Cross, DeWitte T., III [1 ,3 ]
Moran, Christopher J. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Intervent Neuroradiol Sect, Mallinckrodt Inst Radiol, St Louis, MO USA
[2] Univ Florida, Dept Neurosurg, Gainesville, FL USA
[3] Washington Univ, Dept Neurol Surg, Sch Med, St Louis, MO USA
[4] Washington Univ, Sch Med, Dept Neurol, St Louis, MO 63110 USA
关键词
Enterprise stent; intracranial aneurysm; Neuroform stent; stent-assisted coil embolization; EXPANDING NITINOL STENT; CEREBRAL ANEURYSMS; ARTERY; APPOSITION; PLACEMENT; EMBOLIZATION; SIZE;
D O I
10.2214/AJR.12.8954
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The Enterprise stent is the first closed-cell stent designed to treat wide-necked intracranial aneurysms. Advantages of the design can include improvement in keeping coils within an aneurysm and the ability of the stent to be recaptured. We compared the technical and clinical complications of the Enterprise stent with the open-cell Neuroform stent, its primary alternative. SUBJECTS AND METHODS. Patients undergoing Enterprise and Neuroform stent-assisted aneurysm coiling were enrolled in prospective registries starting in March 2007 and February 2003, respectively. All consecutive patients through December 2011 were included. Deployment success and difficulty, stent movement and misplacement, and procedural complications were compared. RESULTS. Enterprise deployment success was high (108 of 115 attempts, 93.9%) with 102 aneurysms receiving a stent compared with Neuroform (173 of 214 attempts, 80.8%, p = 0.001) with 163 aneurysms. Enterprise was easier to deploy (1.7% vs 15.9% difficult deployment, p < 0.0001). There were no significant differences in the rates of stent movement, misplacement, or symptomatic hemorrhage. Symptomatic thromboembolic events, however, were more frequent with the Enterprise stent (8.7% vs 1.4%, p = 0.0021). The Enterprise stent enabled treatment of 10 additional aneurysms that could not be treated with Neuroform and had a higher rate of immediate aneurysm occlusion (87.3% vs 73.0%, p = 0.0058). CONCLUSION. Enterprise was easier to deploy and enabled treatment of additional aneurysms; however, there were more thromboembolic complications. On the basis of these findings, we prefer to use the Neuroform stent first and rely on the Enterprise stent as an easy-to-deliver backup for stent-assisted coiling.
引用
收藏
页码:872 / 878
页数:7
相关论文
共 25 条
[1]   The effect of vascular reconstruction device-assisted coiling on packing density, effective neck coverage, and angiographic outcome: An in vitro study [J].
Bendok, Bernard R. ;
Parkinson, Richard J. ;
Hage, Ziad A. ;
Adel, Joseph G. ;
Gounis, Matthew J. .
NEUROSURGERY, 2007, 61 (04) :835-840
[2]   Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils [J].
Cognard, C ;
Weill, A ;
Spelle, L ;
Piotin, M ;
Castaings, L ;
Rey, A ;
Moret, J .
RADIOLOGY, 1999, 212 (02) :348-356
[3]  
Cross DT, 2005, AM J NEURORADIOL, V26, P2578
[4]   Neuroform in-stent stenosis: Incidence, natural history, and treatment strategies [J].
Fiorella, David ;
Albuquerque, Felipe C. ;
Woo, Henry ;
Rasmussen, Peter A. ;
Masaryk, Thomas J. ;
McDougall, Cameron G. .
NEUROSURGERY, 2006, 59 (01) :34-41
[5]   The Efficacy of Endovascular Stenting in the Treatment of Supraclinoid Internal Carotid Artery Blister Aneurysms Using a Stent-in-Stent Technique [J].
Gaughen, J. R., Jr. ;
Hasan, D. ;
Dumont, A. S. ;
Jensen, M. E. ;
Mckenzie, J. ;
Evans, A. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (06) :1132-1138
[6]   Parent Vessel Size and Curvature Strongly Influence Risk of Incomplete Stent Apposition in Enterprise Intracranial Aneurysm Stent Coiling [J].
Heller, R. S. ;
Malek, A. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1714-1720
[7]   Delivery technique plays an important role in determining vessel wall apposition of the Enterprise self-expanding intracranial stent [J].
Heller, Robert S. ;
Malek, Adel M. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2011, 3 (04) :340-343
[8]   Crescent sign on magnetic resonance angiography revealing incomplete stent apposition: correlation with diffusion-weighted changes in stent-mediated coil embolization of aneurysms [J].
Heller, Robert S. ;
Miele, William R. ;
Do-Dai, Daniel D. ;
Malek, Adel M. .
JOURNAL OF NEUROSURGERY, 2011, 115 (03) :624-632
[9]  
Higashida RT, 2005, AM J NEURORADIOL, V26, P1751
[10]   Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery - Case report and review of the literature [J].
Higashida, RT ;
Smith, W ;
Gress, D ;
Urwin, R ;
Dowd, CF ;
Balousek, PA ;
Halbach, VV .
JOURNAL OF NEUROSURGERY, 1997, 87 (06) :944-949