Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood

被引:0
|
作者
Morris, SS
Ruel, MT
Cohen, RJ
Dewey, KG
de la Brière, B
Hassan, MN
机构
[1] Int Food Policy Res Inst, Food Consumpt & Nutr Div, Washington, DC 20006 USA
[2] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
[3] Univ Dhaka, Inst Nutr & Food Sci, Dhaka, Bangladesh
来源
关键词
nutrition assessment; hemoglobin; error; reliability; precision; accuracy; capillary blood; hemoglobinometer; Honduras; Bangladesh; anemia;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: Previous research has suggested that there may be significant within-subject variability, both site-to-site and over time, in hemoglobin concentrations in capillary blood. Objective: This study examined the reliability of the portable hemoglobinometer (PHM) system with use of capillary blood and the implications of errors of the magnitude found for the classification of anemia status in individuals and population groups. The I,recision and accuracy of the method with use of venous blood were also tested. Design: Three empirical data sets were used to measure reliability, precision, and accuracy of the PHM system [2 from Honduras (n = 87 and 141); 1 from Bangladesh (n = 73)]. Simulation data were used to assess the implications of errors for screening individuals for anemia and to estimate anemia prevalence. Results: High within-subject variability (unreliability) was identified when capillary blood from the left hand was compared with that from the right hand (CV: 6.3%) and when measurements were taken on 4 consecutive days (CV: 7.0%). Reliability was only 69% and 50%, respectively. Precision and accuracy, however, were very high (concordance coefficients of 0.99 and 0.98 and CV < 1%). Conclusions: The simulation data showed that errors of the magnitude found due to unreliability can lead to misclassification of anemia status in individuals and small biases in anemia prevalence estimates. We recommend replicate sampling to reduce the influence of unreliability in the use of the PHM system with capillary blood.
引用
收藏
页码:1243 / 1248
页数:6
相关论文
共 50 条
  • [1] Precision, accuracy and reliability of hemoglobin assessment using capillary blood
    Morris, SS
    Ruel, MT
    Cohen, RJ
    Dewey, KG
    de la Brière, B
    Hassan, MN
    FASEB JOURNAL, 1999, 13 (04): : A534 - A534
  • [2] ACCURACY, PRECISION, AND CLINICAL RELIABILITY OF 3 CAPILLARY BLOOD-GLUCOSE MONITORS
    PRINSEN, J
    EVANS, I
    HEAD, T
    COLE, R
    LEGERE, S
    RUSHKOWSKI, J
    TRUNDLE, D
    GOLDBERG, N
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1135 - 1136
  • [3] Assessment of glycosylated hemoglobin in capillary blood compared to venous blood
    Ferreras Amez, Jose Maria
    Aldea Molina, Elisa
    Ortega Jimenez, Noelia
    Guardia Sancho, Laia
    Gomez Gomez, Maria Antonia
    Blasco Valle, Mariano
    ATENCION PRIMARIA, 2010, 42 (01): : 60 - 61
  • [4] ACCURACY AND PRECISION OF HEMOGLOBIN MEASUREMENTS
    BEELER, MF
    DEUPREE, RH
    GOHEEN, EM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1965, 44 (02) : 203 - &
  • [5] Assessing Accuracy and Precision of Hemoglobin Determination in Venous, Capillary Pool, and Single-Drop Capillary Blood Specimens Using three Different HemoCue® Hb Models: The Multicountry Hemoglobin Measurement (HEME) Study
    Hackl, Laura S.
    Karakochuk, Crystal
    Mazariegos, Dora Ines
    Jeremiah, Kidola
    Obeid, Omar
    Ravi, Nirmal
    Ayana, Desalegn A.
    Varela, Veronica
    Alayon, Silvia
    Dary, Omar
    Moorthy, Denish
    JOURNAL OF NUTRITION, 2024, 154 (07): : 2326 - 2334
  • [6] PRINCIPLES FOR ASSESSMENT OF RELIABILITY OF RADIOIMMUNOASSAY METHODS (PRECISION, ACCURACY, SENSITIVITY, SPECIFICITY)
    MIDGLEY, AR
    NISWENDER, GD
    REBAR, RW
    ACTA ENDOCRINOLOGICA, 1969, S 63 : 163 - +
  • [7] HOW RELIABILITY, PRECISION AND ACCURACY REFER TO USE OF WORK MEASUREMENT DATA
    FEIN, M
    INDUSTRIAL ENGINEERING, 1981, 13 (07): : 26 - 33
  • [8] Accuracy and precision assessment of a new blood glucose monitoring system
    Ji, Li-Nong
    Guo, Li-Xin
    Liu, Li-Bin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (01) : 181 - 188
  • [9] Reliability, precision, accuracy, and validity of posterior shoulder tightness assessment in overhead athletes
    Myers, Joseph B.
    Oyama, Sakiko
    Wassinger, Craig A.
    Ricci, Robert D.
    Abt, John R.
    Conley, Kevin M.
    Lephart, Scott M.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (11): : 1922 - 1930
  • [10] HEMOGLOBIN MEASUREMENT IN CAPILLARY BLOOD WITH THE HEMATOFLUOROMETER
    SCHIFMAN, RB
    ANGEL, E
    LAMOLA, A
    RIVERS, SL
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1284 - 1284