Comparison of standard and heat-pipe fins with specified tip temperature condition

被引:9
作者
Bowman, WJ [1 ]
Maynes, D [1 ]
机构
[1] Brigham Young Univ, Dept Mech Engn, Provo, UT 84602 USA
关键词
D O I
10.2514/2.6645
中图分类号
O414.1 [热力学];
学科分类号
摘要
Analytical expressions for heat-pipe fin temperature distribution and efficiency were obtained for a fin with uniform cross-sectional area, convection, thermal conductivity, and where the fin-tip temperature is specified. The results were compared to a standard (solid conductor) fin. It was observed that under most conditions, the heat-pipe fin would have a higher efficiency than a geometrically similar standard fin. The important parameters needed to compare the two types of fins are presented.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 4 条
[1]   Efficiency of a constant-area, adiabatic tip, heat pipe fin [J].
Bowman, WJ ;
Moss, TW ;
Maynes, D ;
Paulson, KA .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2000, 14 (01) :112-115
[2]   Analytical comparison of constant area, adiabatic tip, standard fins, and heat pipe fins [J].
Bowman, WJ ;
Storey, JK ;
Svensson, KI .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1999, 13 (02) :269-272
[3]  
DUNN P, 1978, HEAT PIPES, P80
[4]  
INCROPERA FP, 1996, FUNDAMENTALS HEAT MA, P117