Fragility Analysis of Transmission Line Subjected to Wind Loading

被引:58
|
作者
Fu, Xing [1 ]
Li, Hong-Nan [1 ,2 ]
Tian, Li [3 ]
Wang, Jia [1 ]
Cheng, Hu [1 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116023, Peoples R China
[2] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Liaoning, Peoples R China
[3] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Transmission tower; Fragility analysis; Wind load; Probability of failure; Uncertainty analysis; DYNAMIC-ANALYSIS; TOWER; CONDUCTORS; GUSTINESS; DOWNBURST; SPECTRUM; SYSTEM; RAIN;
D O I
10.1061/(ASCE)CF.1943-5509.0001311
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Neither structural properties nor wind loads are deterministic; accordingly, a fragility analysis of overhead transmission towers can be employed to comprehensively evaluate their strength capacity. Here, a fragility analysis method for a transmission line under wind loading is developed that incorporates the uncertainties of structural parameters and wind loads into a numerical model. First, a simplified model with one tower and two span lines is presented to improve calculation efficiency; this model is validated via a comparison with a complete tower-line system under both static and dynamic conditions. Then the fragility analysis process for transmission towers subjected to wind loading is presented in three main steps: development of uncertainty models and wind loadings, nonlinear dynamic analysis, and regression analysis. Afterwards, the random variables and their corresponding probability distributions are determined. Finally, a case study of a real operational transmission tower under wind loading is carried out. The results indicate that the consideration of a greater number of uncertainty parameters leads to a greater dispersion of the fragility curve and that the wind attack angle has a significant influence on the fragility curve.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Measurements of downburst wind loading acting on an overhead transmission line in Northern Germany
    Stengel, Dominik
    Thiele, Klaus
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 3152 - 3157
  • [42] Finite element modelling of transmission line structures under tornado wind loading
    Hamada A.
    Damatty A.A.E.
    Hangan H.
    Shehata A.Y.
    Wind and Structures, An International Journal, 2010, 13 (05): : 451 - 469
  • [43] Finite element modelling of transmission line structures under tornado wind loading
    Hamada, A.
    El Damatty, A. A.
    Hangan, H.
    Shehata, A. Y.
    WIND AND STRUCTURES, 2010, 13 (05) : 451 - 469
  • [44] Fragility Analysis of Wind-Induced Collapse of a Transmission Tower Considering Corrosion
    Liu, Chuncheng
    Yan, Zhao
    BUILDINGS, 2022, 12 (10)
  • [45] Capacity of transmission tower-line system subjected to concurrent wind and ice loads
    Xiao, M. Y.
    Hong, H. P.
    STRUCTURES, 2025, 71
  • [46] A pounding spacer damper and its application on transmission line subjected to fluctuating wind load
    Fu, Xing
    Li, Hong-Nan
    Li, Jia-Xiang
    Zhang, Peng
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (08):
  • [47] Analytical model of high-voltage transmission line subjected to the downburst wind with rainfall
    Zhou, Chao
    Liu, Yibing
    ADVANCES IN MECHANICAL ENGINEERING, 2015, 7 (03) : 1 - 13
  • [48] Fragility Assessment for Cladding of Industrial Buildings Subjected to Extreme Wind
    Lee, Sungsu
    Ham, Hee Jung
    Kim, Ho-Jeong
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2013, 12 (01) : 65 - 72
  • [49] Fragility curves for woodframe structures subjected to lateral wind loads
    Lee, KH
    Rosowsky, DV
    WIND AND STRUCTURES, 2006, 9 (03) : 217 - 230
  • [50] Behaviour of a hemispherical dome subjected to wind loading
    Montes, P
    Fernandez, A
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (10) : 911 - 924