Fragility Analysis of Transmission Line Subjected to Wind Loading

被引:58
|
作者
Fu, Xing [1 ]
Li, Hong-Nan [1 ,2 ]
Tian, Li [3 ]
Wang, Jia [1 ]
Cheng, Hu [1 ]
机构
[1] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116023, Peoples R China
[2] Shenyang Jianzhu Univ, Sch Civil Engn, Shenyang 110168, Liaoning, Peoples R China
[3] Shandong Univ, Sch Civil Engn, Jinan 250061, Shandong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Transmission tower; Fragility analysis; Wind load; Probability of failure; Uncertainty analysis; DYNAMIC-ANALYSIS; TOWER; CONDUCTORS; GUSTINESS; DOWNBURST; SPECTRUM; SYSTEM; RAIN;
D O I
10.1061/(ASCE)CF.1943-5509.0001311
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Neither structural properties nor wind loads are deterministic; accordingly, a fragility analysis of overhead transmission towers can be employed to comprehensively evaluate their strength capacity. Here, a fragility analysis method for a transmission line under wind loading is developed that incorporates the uncertainties of structural parameters and wind loads into a numerical model. First, a simplified model with one tower and two span lines is presented to improve calculation efficiency; this model is validated via a comparison with a complete tower-line system under both static and dynamic conditions. Then the fragility analysis process for transmission towers subjected to wind loading is presented in three main steps: development of uncertainty models and wind loadings, nonlinear dynamic analysis, and regression analysis. Afterwards, the random variables and their corresponding probability distributions are determined. Finally, a case study of a real operational transmission tower under wind loading is carried out. The results indicate that the consideration of a greater number of uncertainty parameters leads to a greater dispersion of the fragility curve and that the wind attack angle has a significant influence on the fragility curve.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Fragility analysis of a long-span transmission tower-line system under wind loads
    Tian, Li
    Zhang, Xin
    Fu, Xing
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (10) : 2110 - 2120
  • [22] Fragility assessment of wood sheathing panels and roof-to-wall connections subjected to wind loading
    Gill, Amira
    Genikomsou, Aikaterini S.
    Balomenos, Georgios P.
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2021, 15 (04) : 867 - 876
  • [23] Dynamic analysis of an overhead transmission line subject to gusty wind loading predicted by wind-conductor interaction
    Keyhan, Hooman
    McClure, Ghyslaine
    Habashi, Wagdi G.
    COMPUTERS & STRUCTURES, 2013, 122 : 135 - 144
  • [24] Fragility analysis of an ageing monopile offshore wind turbine subjected to simultaneous wind and seismic load
    Baran Yeter
    Mesut Tekgoz
    Yordan Garbatov
    Carlos Guedes Soares
    Safety in Extreme Environments, 2020, 2 (2): : 155 - 170
  • [25] Fragility assessment of a transmission tower subjected to wind load based on big data and deep learning
    Li, Hongnan
    Zhang, Wensheng
    Fu, Xing
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 (09): : 54 - 64
  • [26] Shell analysis of an inflatable arch subjected to snow and wind loading
    Plaut, RH
    Goh, JKS
    Kigudde, M
    Hammerand, DC
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2000, 37 (31) : 4275 - 4288
  • [27] Collapse failure analysis and fragility analysis of a transmission tower-line system subjected to the multidimensional ground motion of different input directions
    Tian, Li
    Yang, Meng
    Liu, Shiyuan
    Liu, Juncai
    Gao, Guodong
    Yang, Zeying
    STRUCTURES, 2023, 48 : 1018 - 1028
  • [28] Geospatial analysis of wind velocity to determine wind loading on transmission tower
    Hamzah, Nur H.
    Usman, Fathoni
    WIND AND STRUCTURES, 2019, 28 (06) : 381 - 388
  • [29] Finite element modeling of transmission line under downburst wind loading
    Shehata, AY
    El Damatty, AA
    Savory, E
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2005, 42 (01) : 71 - 89
  • [30] Assessment of capacity curves for transmission line towers under wind loading
    Banik, S. S.
    Hong, H. P.
    Kopp, Gregory A.