Changes in the position of epidural catheters associated with patient movement

被引:73
作者
Hamilton, CL [1 ]
Riley, ET [1 ]
Cohen, SE [1 ]
机构
[1] STANFORD UNIV,SCH MED,DEPT ANESTHESIA,STANFORD,CA 94305
关键词
anesthesia; obstetric; anesthetic techniques; epidural; equipment; peridural catheters;
D O I
10.1097/00000542-199704000-00007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Epidural catheter movement has been noted with change of patient position and can result in inadequate anesthesia. This study was designed to measure movement and to develop a technique that minimizes catheter displacement. Methods: In 255 parturients requesting epidural anesthesia for labor or cesarean section, a multiorificed lumbar epidural catheter was inserted with the patient in the sitting flexed position. The distance to the epidural space, length of catheter inserted, and amount of catheter position change as the patient moved from the sitting flexed to sitting upright and then to the lateral decubitus position mere measured before the catheter was secured to the skin. Adequacy of analgesia, the need for catheter manipulation, and whether the patient was considered obese were noted. Data were grouped according to body mass index (BMT): < 25, 25-30, and > 30 kg/m(2). Results: The groups did not differ with respect to the length of catheter initially inserted or changes in catheter position between initial taping and removal. The distance to the epidural space differed significantly among the groups, increasing with greater BMI. Catheters frequently appeared to be drawn inward with position change from the sitting flexed to lateral decubitus position, with the greatest change seen in patients with BMI > 30. Only nine catheters were associated with inadequate analgesia, four of which were replaced. No analgesic failures occurred in the BMI > 30 group. In patients judged by the anesthesiologist to be obese or to have an obese back, BMI was greater, and the distance to the epidural space and the magnitude of catheter movement with position change were greater than in those who were not obese. Conclusions: Epidural catheters moved a clinically significant amount with reference to the skin in all BMI groups as patients changed position. Lf catheters had been secured to the skin before position change, many would have been pulled partially out of the epidural space. To minimize the risk of catheter displacement, particularly in obese patients, Re recommend that multiorificed catheters be inserted at least 4 cm into the epidural space and that patients assume the sitting upright or lateral position before securing the catheter to the skin.
引用
收藏
页码:778 / 784
页数:7
相关论文
共 50 条
  • [1] EPIDURAL-ANESTHESIA FOR POSTPARTUM TUBAL-LIGATION USING EPIDURAL CATHETERS PLACED DURING LABOR
    VINCENT, RD
    REID, RW
    JOURNAL OF CLINICAL ANESTHESIA, 1993, 5 (04) : 289 - 291
  • [2] Evaluation of thoracic epidural catheter position and migration using radio-opaque catheters
    Hendriks, GWH
    Hasenbos, MAWM
    Gielen, MJM
    vonEgmond, J
    Barentsz, JO
    ANAESTHESIA, 1997, 52 (05) : 457 - 459
  • [3] A COMPARATIVE-STUDY OF PATIENT-CONTROLLED EPIDURAL FENTANYL AND SINGLE-DOSE EPIDURAL MORPHINE FOR POSTCESAREAN ANALGESIA
    YU, PYH
    GAMBLING, DR
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (05): : 416 - 420
  • [4] EPIDURAL CATHETERS FOR OBSTETRICS - TERMINAL HOLE OR LATERAL EYES
    COLLIER, CB
    GATT, SP
    REGIONAL ANESTHESIA, 1994, 19 (06) : 378 - 385
  • [5] INFLAMMATORY CUTANEOUS REACTIONS TO EPIDURAL CATHETERS
    MATHER, CMP
    READY, LB
    NEWMAN, M
    ANESTHESIOLOGY, 1993, 78 (01) : 200 - 203
  • [6] EPIDURAL CATHETERS - BREAKING AND EXTRACTION FORCES
    DAVIES, R
    VAUGHAN, RS
    RICHARDS, J
    ANAESTHESIA, 1993, 48 (10) : 900 - 901
  • [7] PATIENT-CONTROLLED EPIDURAL ANALGESIA IN LABOR - VARYING BOLUS DOSE AND LOCKOUT INTERVAL
    GAMBLING, DR
    HUBER, CJ
    BERKOWITZ, J
    HOWELL, P
    SWENERTON, JE
    ROSS, PLE
    CROCHETIERE, CT
    PAVY, TJG
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03): : 211 - 217
  • [8] Influence of patient position on withdrawal forces during removal of lumbar extradural catheters
    Morris, GN
    Warren, BB
    Hanson, EW
    Mazzeo, FJ
    DiBenedetto, DJ
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (03) : 419 - 420
  • [9] The coiling length of thoracic epidural catheters: the influence of epidural approach angle
    Ryu, H. -G.
    Bahk, J. -H.
    Lee, C. -J.
    Lim, Y. -J.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (03) : 401 - 404
  • [10] THE AIR TEST AS A CLINICALLY USEFUL INDICATOR OF INTRAVENOUSLY PLACED EPIDURAL CATHETERS
    LEIGHTON, BL
    NORRIS, MC
    DESIMONE, CA
    ROSKO, T
    GROSS, JB
    ANESTHESIOLOGY, 1990, 73 (04) : 610 - 613