Biomechanical Testing of Two-Unit Bridges and a Comparison of Replacement Retention Depending on a Cementation Medium, Replacement Position, and Gap Size

被引:1
作者
Balogova, Alena Findrik [1 ]
Rajt'ukova, Viktoria [1 ]
Chromy, Lubos [1 ]
Somos, Andrej [2 ]
Izarikova, Gabriela [3 ]
Hudak, Radovan [1 ]
机构
[1] Tech Univ KoSice, Fac Mech Engn, Dept Biomed Engn & Measurement, Kosice 04001, Slovakia
[2] L Pasteur Univ Hosp Kosice, Clin Pneumol & Phthisiol, Kosice 04011, Slovakia
[3] Tech Univ Kosice, Fac Mech Engn, Dept Appl Math & Informat, Kosice 04001, Slovakia
关键词
biomechanical testing; cobalt-chrome; dental cement; dental replacements; gap size; INTERNAL FIT; DENTAL ALLOYS; MARGINAL FIT; CROWNS;
D O I
10.3390/jfb13040286
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dental replacements are placed between the abutment teeth. The exceptions are two-unit bridges, as they are supported by a single tooth prepared only on one side of the missing tooth. The presented study deals with an analysis of a pressure force action on two-unit bridges placed in the frontal part (20 samples), where the pressure action is lower, and in the distal part (20 samples), where the pressure action is higher. A CAD program by 3Shape was used for digital designing with two different gap settings, 10 mu m (20 samples) and 30 mu m (20 samples). Two-unit bridges were attached to the prepared tooth using two types of dental cement (20/20 samples), which were selected for their physical and bioactive properties. All two-unit bridges (a total of 80 samples) were fabricated from CoCr alloys on Mlab cusing R by applying the Selective Laser Melting (SLM) technology. Mechanical testing was performed using the Inspekt5 table blue. The obtained data were used to verify the hypotheses-a difference between both types of cement (A not equal B), a difference between the frontal and distal two-unit bridges (F not equal D) and a difference between the gap sizes (10 not equal 30). To confirm the given theories, data were statistically evaluated using the F-test and subsequent t-tests. The resulting p-value was compared with the level of significance (alpha = 0.05). A statistical evaluation revealed a significant difference between the compared groups; however, no explicit correlation between the individual groups of specimens was identified.
引用
收藏
页数:13
相关论文
共 35 条
[1]  
A D N., 2016, Materials Science. Non-Equilibrium Phase Transformations, V2, P3
[2]   Adhesive Systems Used in Indirect Restorations Cementation: Review of the Literature [J].
Abad-Coronel, Cristian ;
Naranjo, Belen ;
Valdiviezo, Pamela .
DENTISTRY JOURNAL, 2019, 7 (03)
[3]  
Ajay R, 2017, J PHARM BIOALLIED SC, V9, pS154, DOI 10.4103/jpbs.JPBS_146_17
[4]  
Alqahtani F, 2017, CLIN COSMET INVESTIG, V9, P13, DOI 10.2147/CCIDE.S130856
[5]  
Ammarullah MI, 2022, J TRIBOLOGI, V33, P31
[6]  
Anusavice KJ., 2013, Phillips science of dental materials
[7]  
Ayesha, 2020, INT J DENT MED, V4, P7, DOI [10.11648/j.ijdm.20200601.12, DOI 10.11648/J.IJDM.20200601.12]
[8]   A comparative study of additive and subtractive manufacturing for dental restorations [J].
Bae, Eun-Jeong ;
Jeong, Il-Do ;
Kim, Woong-Chul ;
Kim, Ji-Hwan .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) :187-193
[9]   Applications of additive manufacturing in dentistry: A review [J].
Bhargav, Aishwarya ;
Sanjairaj, Vijayavenkatraman ;
Rosa, Vinicius ;
Feng, Lu Wen ;
Fuh, Jerry Y. H. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (05) :2058-2064
[10]   Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study [J].
Braian, Michael ;
Jonsson, David ;
Kevci, Mir ;
Wennerberg, Ann .
DENTAL MATERIALS, 2018, 34 (07) :978-993