Apparent diffusion coefficient values in peripheral and transition zones of the prostate: Comparison between normal and malignant prostatic tissues and correlation with histologic grade

被引:214
作者
Tamada, Tsutomu [1 ]
Sone, Teruki [1 ]
Jo, Yoshimasa [2 ]
Toshimitsu, Shinya [3 ]
Yamashita, Takenori [1 ]
Yamamoto, Akira [1 ]
Tanimoto, Daigo [1 ]
Ito, Katsuyoshi [1 ]
机构
[1] Kawasaki Med Sch, Dept Radiol, Kurashiki, Okayama 7010192, Japan
[2] Kawasaki Med Sch, Dept Urol, Kurashiki, Okayama 7010192, Japan
[3] Hiroshima Heiwa Clinic, Dept Radiol, Hiroshima, Japan
关键词
prostate cancer; diffusion magnetic resonance imaging; apparent diffusion coefficient; peripheral zone; transition zone; histologic type of neoplasm;
D O I
10.1002/jmri.21503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the utility of apparent diffusion coefficient (ADC) values for discriminating tumor in patients with prostate cancer from normal prostatic tissues in healthy adult men, and to identify correlations between ADC and histologic grade of prostate cancer. Materials and Methods: A total of 125 healthy male volunteers (mean age. 60 years; range, 50-86 years) and 90 prostate cancer patients (mean age, 71 years; range, 51-88 years) underwent diffusion-weighted imaging (DWI) of the prostate with a single-shot echo-planar imaging sequence using b-factors of 0 and 800 see/mm(2). ADC was measured from two locations in the peripheral zone (PZ) and two locations in the central gland (CG) in normal subjects, and tumor locations of PZ or transition zone (TZ) in patients with prostate cancer. Results: Mean ADC values of tumor regions in both PZ (1.02 +/- 0.25 x 10(-3) mm(2)/sec) and TZ (0.94 +/- 0.21. x 10(-3) mm(2)/sec) were significantly lower than those in the corresponding normal regions (1.80 +/- 0.27 x 10(-3) mm(2)/sec and 1.34 +/- 0.14 x 10(-3) mm(2)/sec, respectively) (P < 0.0001 each). Furthermore, a significant negative correlation was identified between ADC in PZ cancer and tumor Gleason score (rho = -0.497, P < 0.0001). Conclusion: ADC values appear to provide acceptable diagnostic accuracy in both PZ and TZ.
引用
收藏
页码:720 / 726
页数:7
相关论文
共 39 条
[1]   Transition zone prostate cancers: Features, detection, localization, and staging at endorectal MR imaging [J].
Akin, Oguz ;
Sala, Evis ;
Moskowitz, Chaya S. ;
Kuroiwa, Kentaro ;
Ishill, Nicole M. ;
Pucar, Darko ;
Scardino, Peter T. ;
Hricak, Hedvig .
RADIOLOGY, 2006, 239 (03) :784-792
[2]   Effects of cell volume fraction changes on apparent diffusion in human cells [J].
Anderson, AW ;
Xie, J ;
Pizzonia, J ;
Bronen, RA ;
Spencer, DD ;
Gore, JC .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :689-695
[3]   THE VALUE OF SCREENING-TESTS IN THE DETECTION OF PROSTATE-CANCER .1. RESULTS OF A RETROSPECTIVE EVALUATION OF 1726 MEN [J].
BANGMA, CH ;
KRANSE, R ;
BLIJENBERG, BG ;
SCHRODER, FH .
UROLOGY, 1995, 46 (06) :773-778
[4]  
Brooks JD, 1998, CAMPBELLS UROLOGY, P89
[5]  
Castillo M, 2001, AM J NEURORADIOL, V22, P60
[6]   COMPARISON OF DIGITAL RECTAL EXAMINATION AND SERUM PROSTATE-SPECIFIC ANTIGEN IN THE EARLY DETECTION OF PROSTATE-CANCER - RESULTS OF A MULTICENTER CLINICAL-TRIAL OF 6,630 MEN [J].
CATALONA, WJ ;
RICHIE, JP ;
AHMANN, FR ;
HUDSON, MA ;
SCARDINO, PT ;
FLANIGAN, RC ;
DEKERNION, JB ;
RATLIFF, TL ;
KAVOUSSI, LR ;
DALKIN, BL ;
WATERS, WB ;
MACFARLANE, MT ;
SOUTHWICK, PC .
JOURNAL OF UROLOGY, 1994, 151 (05) :1283-1290
[7]   Detection of prostate cancer by integration of line-scan diffusion, T2-mapping and T2-weighted magnetic resonance imaging; a multichannel statistical classifier [J].
Chan, I ;
Wells, W ;
Mulkern, RV ;
Haker, S ;
Zhang, JQ ;
Zou, KH ;
Maier, SE ;
Tempany, CMC .
MEDICAL PHYSICS, 2003, 30 (09) :2390-2398
[8]   Prostate cancer tumor volume: Measurement with endorectal MR and MR spectroscopic imaging [J].
Coakley, FV ;
Kurhanewicz, J ;
Lu, Y ;
Jones, KD ;
Swanson, MG ;
Chang, SD ;
Carroll, PR ;
Hricak, H .
RADIOLOGY, 2002, 223 (01) :91-97
[9]   Magnetic resonance imaging in prostate cancer: the value of apparent diffusion coefficients for identifying malignant nodules [J].
DeSouza, N. M. ;
Reinsberg, S. A. ;
Scurr, E. D. ;
Brewster, J. M. ;
Payne, G. S. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (950) :90-95
[10]   Diffusion imaging of the prostate at 3.0 tesla [J].
Gibbs, P ;
Pickles, MD ;
Turnbull, LW .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :185-188