Safety for Human MR Scanners at 7T

被引:7
作者
Okada, Tomohisa [1 ,2 ]
Akasaka, Thai [1 ]
Thuy, Dinh H. D. [1 ]
Isa, Tadashi [1 ]
机构
[1] Kyoto Univ, Human Brain Res Ctr, Grad Sch Med, Kyoto, Kyoto, Japan
[2] Kyoto Univ, Human Brain Res Ctr, Grad Sch Med, 54 Shogoin Kawaharacho,Sakyo ku, Kyoto, Kyoto 6068507, Japan
关键词
safety; 7; tesla; magnetic resonance imaging; DOUBLE INVERSION-RECOVERY; STATIC MAGNETIC-FIELD; TEMPORAL-LOBE EPILEPSY; DEEP GRAY-MATTER; FOCUS LATERALITY; GRAVID UTERUS; EXPOSURE; BRAIN; TESLA; BODY;
D O I
10.2463/mrms.rev.2021-0063
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
After introduction of the first human 7 tesla (7T) system in 1999, 7T MR systems have been employed as one of the most advanced platforms for human MR research for more than 20 years. Currently, two 7T MR models are approved for clinical use in the U.S.A. The approval facilitated introduction of the 7T system, summing up to around 100 worldwide. The approval in Japan is much awaited. As a clinical MR scanner, the 7T MR system is drawing attention in terms of safety.Several large-sized studies on bioeffects have been reported for vertigo, dizziness, motion disturbances, nausea, and others. Such effects might also be found in MR workers and researchers. Frequency and severity of reported bioeffects will be presented and discussed, including their variances. The high resonance frequency and shorter RF wavelength of 7T increase the concern about the safety. Homogeneous RF pulse excitation is difficult even for the brain, and a multi-channel parallel transmit (pTx) system is considered mandatory. However, pTx may create a hot spot, which makes the estimation of specific absorption rate (SAR) to be difficult. The stronger magnetic field of 7T causes a large force of displacement and heating on metallic implants or devices, and the scan of patients with them should not be conducted at 7T. However, there are some opinions that such patients might be scanned even at 7T, if certain criteria are met. This article provides a brief review on the effect of the static magnetic field on humans (MR subjects, workers, and researchers) and neurons, in addition to scan sound, SAR, and metal implants and devices. Understanding and avoiding adverse effects will contribute to the reduction in safety risks and the prevention of incidents.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 50 条
  • [41] Development of Chemical Exchange Saturation Transfer at 7T
    Dula, Adrienne N.
    Asche, Elizabeth M.
    Landman, Bennett A.
    Welch, E. Brian
    Pawate, Siddharama
    Sriram, Subramaniam
    Gore, John C.
    Smith, Seth A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) : 831 - 838
  • [42] Anatomical Brain Imaging at 7T Using Two-Dimensional GRASE
    Trampel, Robert
    Reimer, Enrico
    Huber, Laurentius
    Ivanov, Dimo
    Heidemann, Robin M.
    Schaefer, Andreas
    Turner, Robert
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (05) : 1291 - 1301
  • [43] Detection of cerebral NAD+ in humans at 7T
    de Graaf, Robin A.
    De Feyter, Henk M.
    Brown, Peter B.
    Nixon, Terence W.
    Rothman, Douglas L.
    Behar, Kevin L.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 828 - 835
  • [44] Reproducibility Measurement of Glutathione, GABA, and Glutamate: Towards In Vivo Neurochemical Profiling of Multiple Sclerosis With MR Spectroscopy at 7T
    Prinsen, Hetty
    de Graaf, Robin A.
    Mason, Graeme F.
    Pelletier, Daniel
    Juchem, Christoph
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 187 - 198
  • [45] Doppler ultrasound triggering for cardiac MRI at 7T
    Kording, F.
    Ruprecht, C.
    Schoennagel, B.
    Fehrs, K.
    Yamamura, J.
    Adam, G.
    Goebel, J.
    Nassenstein, K.
    Maderwald, S.
    Quick, H. H.
    Kraff, O.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 239 - 247
  • [46] Retinotopic mapping with spin echo BOLD at 7T
    Olman, Cheryl A.
    Van de Moortele, Pierre-Francois
    Schumacher, Jennifer F.
    Guy, Joseph R.
    Ugurbil, Kamil
    Yacoub, Essa
    MAGNETIC RESONANCE IMAGING, 2010, 28 (09) : 1258 - 1269
  • [47] No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
    Burkett, Brian J.
    Rasmussen, Chad M.
    Fillmore, W. Jonathan
    McDonald, Jennifer S.
    McDonald, Robert J.
    Fagan, Andrew J.
    Erdahl, Sarah A.
    Eckdahl, Steven J.
    Welker, Kirk M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 660 - 669
  • [48] The Learning-based Automatic Segmentation Algorithm of Brain MR Images Based on 7T
    Deng, Minghui
    Jin Zhenhao
    Yu, Ran
    Zeng, Qingshuang
    CURRENT MEDICAL IMAGING, 2021, 17 (03) : 342 - 351
  • [49] A cascaded nested network for 3T brain MR image segmentation guided by 7T labeling *
    Wei, Jie
    Wu, Zhengwang
    Wang, Li
    Bui, Toan Duc
    Qu, Liangqiong
    Yap, Pew-Thian
    Xia, Yong
    Li, Gang
    Shen, Dinggang
    PATTERN RECOGNITION, 2022, 124
  • [50] MR Imaging at 3.0 T in Children: Technical Differences, Safety Issues, and Initial Experience
    Chavhan, Govind B.
    Babyn, Paul S.
    Singh, Manoj
    Vidarsson, Logi
    Shroff, Manohar
    RADIOGRAPHICS, 2009, 29 (05) : 1451 - U291