Investigation of a diffuse optical measurements-assisted quantitative photoacoustic tomographic method in reflection geometry

被引:12
作者
Xu, Chen [1 ]
Kumavor, Patrick D. [1 ]
Aguirre, Andres [1 ]
Zhu, Quing [1 ]
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
关键词
absorption coefficient; photoacoustic tomography; reflection geometry; diffuse optical measurements; fitting procedure; ABSORPTION COEFFICIENT; BREAST-LESIONS; TURBID MEDIA; RECONSTRUCTION; SPECTROSCOPY; LIGHT;
D O I
10.1117/1.JBO.17.6.061213
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Photoacoustic tomography provides the distribution of absorbed optical energy density, which is the product of optical absorption coefficient and optical fluence distribution. We report the experimental investigation of a novel fitting procedure that quantitatively determines the optical absorption coefficient of chromophores. The experimental setup consisted of a hybrid system of a 64-channel photoacoustic imaging system with a frequency-domain diffused optical measurement system. The fitting procedure included a complete photoacoustic forward model and an analytical solution of a target chromophore using the diffusion approximation. The fitting procedure combines the information from the photoacoustic image and the background information from the diffuse optical measurements to minimize the photoacoustic measurements and forward model data and recover the target absorption coefficient quantitatively. 1-cm-cube phantom absorbers of high and low contrasts were imaged at depths of up to 3.0 cm. The fitted absorption coefficient results were at least 80% of their true values. The sensitivities of this fitting procedure to target location, target radius, and background optical properties were also investigated. We found that this fitting procedure was most sensitive to the accurate determination of the target radius and depth. Blood sample in a thin tube of radius 0.58 mm, simulating a blood vessel, was also studied. The photoacoustic images and fitted absorption coefficients are presented. These results demonstrate the clinical potential of this fitting procedure to quantitatively characterize small lesions in breast imaging. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.6.061213]
引用
收藏
页数:11
相关论文
共 34 条
[1]   Opto-acoustic tomography of breast cancer with arc-array-transducer [J].
Andreev, VG ;
Karabutov, AA ;
Solomatin, SV ;
Savateeva, EV ;
Aleynikov, V ;
Zhulina, YV ;
Fleming, RD ;
Oraevsky, AA .
BIOMEDICAL OPTOACOUSTICS, 2000, 3916 :36-47
[2]   SCATTERING OF DIFFUSE PHOTON DENSITY WAVES BY SPHERICAL INHOMOGENEITIES WITHIN TURBID MEDIA - ANALYTIC SOLUTION AND APPLICATIONS [J].
BOAS, DA ;
OLEARY, MA ;
CHANCE, B ;
YODH, AG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (11) :4887-4891
[3]   Whole-body three-dimensional optoacoustic tomography system for small animals [J].
Brecht, Hans-Peter ;
Su, Richard ;
Fronheiser, Matthew ;
Ermilov, Sergey A. ;
Conjusteau, Andre ;
Oraevsky, Alexander A. .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)
[4]   Simultaneous near-infrared diffusive light and ultrasound imaging [J].
Chen, NG ;
Guo, PY ;
Yan, SK ;
Piao, DQ ;
Zhu, Q .
APPLIED OPTICS, 2001, 40 (34) :6367-6380
[5]   Bulk optical properties of healthy female breast tissue [J].
Durduran, T ;
Choe, R ;
Culver, JP ;
Zubkov, L ;
Holboke, MJ ;
Giammarco, J ;
Chance, B ;
Yodh, AG .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2847-2861
[6]   Laser optoacoustic imaging system for detection of breast cancer [J].
Ermilov, Sergey A. ;
Khamapirad, Tuenchit ;
Conjusteau, Andre ;
Leonard, Morton H. ;
Lacewell, Ron ;
Mehta, Ketan ;
Miller, Tom ;
Oraevsky, Alexander A. .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
[7]  
Gamelin J., 2009, P SOC PHOTO-OPT INS, V7177, P0701
[8]   Time-domain scanning optical mammography: II. Optical properties and tissue parameters of 87 carcinomas [J].
Grosenick, D ;
Wabnitz, H ;
Moesta, KT ;
Mucke, J ;
Schlag, PM ;
Rinneberg, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (11) :2451-2468
[9]   Calibration-free absolute quantification of optical absorption coefficients using acoustic spectra in 3D photoacoustic microscopy of biological tissue [J].
Guo, Zijian ;
Hu, Song ;
Wang, Lihong V. .
OPTICS LETTERS, 2010, 35 (12) :2067-2069
[10]   Image reconstruction for photoacoustic scanning of tissue structures [J].
Hoelen, CGA ;
de Mul, FFM .