OPTIMIZATION OF CONTINUOUS FLOW HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY FOR SENSITIVITY IMPROVEMENT OF BISMUTH

被引:13
作者
Kilinc, Ersin [1 ]
Aydin, Firat [1 ]
机构
[1] Dicle Univ, Fac Sci, Dept Chem, Chem Anal Lab, TR-21280 Diyarbakir, Turkey
关键词
Bismuth; Hydride generation; ICP-OES; Optimization; Sensitivity; ATOMIC-ABSORPTION-SPECTROMETRY; TRACE-ELEMENT DETERMINATION; FLUORESCENCE SPECTROMETRY; MASS-SPECTROMETRY; FORMING ELEMENTS; ENVIRONMENTAL-SAMPLES; INTRODUCTION SYSTEM; SELENIUM; SE; BI;
D O I
10.1080/00032719.2012.696224
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Experimental variables in continuous flow hydride generation inductively coupled plasma-optical emission spectrometry (CF-HG-ICP-OES) were optimized for determination of bismuth. Concentrations of NaBH4, HCl, and NaOH, flow rates of NaBH4, sample solution, waste and carrier argon, radio frequency power, lengths of reaction, and stripping coils were optimized to obtain lower detection limits. Under optimum conditions, the detection limit was calculated as 0.16 ng mL(-1), and the calibration plot was linear between 1.0-50.0 ng mL(-1). An improvement in detection limit of 5.75 times by CF-HG-ICP-OES was reached vs. ICP-OES. Relative standard deviation (RSD) for ten replicate measurements of 10.0 ng mL(-1) Bi was calculated as 3.9%. Effect of possible interferic ions on Bi signal was evaluated. Accuracy of method was verified by using a standard reference material, SRM 1643e. Results found for Bi were in satisfactory agreement with certified values. The proposed method was then employed to determine trace concentration of Bi in milk samples. Bi amounts in samples were found in the range from lower than the quantitation limit to 14.5 ng mL(-1), whereas Bi concentrations were lower than the detection limit in three samples.
引用
收藏
页码:2623 / 2636
页数:14
相关论文
共 44 条
[1]  
Aastroem O., 1982, ANAL CHEM, V54, P190
[2]   Simultaneous determination of antimony and bismuth by beta-correction spectrophotometry and an artificial neural network algorithm [J].
Abbaspour, A ;
Baramakeh, L .
TALANTA, 2005, 65 (03) :692-699
[3]   Possibilities and limits of the simultaneous determination of As, Bi, Ge, Sb, Se, and Sn by flow injection-hydride generation-inductively coupled plasma-time-of-flight mass spectrometry (FI-HG-ICP-TOFMS) [J].
Abrankó, L ;
Stefánka, Z ;
Fodor, P .
ANALYTICA CHIMICA ACTA, 2003, 493 (01) :13-21
[4]   Cloud point extraction spectrophotometric determination of trace quantities of bismuth in urine [J].
Afkhami, Abbas ;
Madrakian, Tayyebeh ;
Siampour, Hajar .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2006, 17 (04) :797-802
[5]   From mg/kg to pg/kg Levels: A Story of Trace Element Determination: A Review [J].
Bakirdere, S. ;
Aydin, F. ;
Bakirdere, E. G. ;
Titretir, S. ;
Akdeniz, I. ;
Aydin, I. ;
Yildirim, E. ;
Arslan, Y. .
APPLIED SPECTROSCOPY REVIEWS, 2011, 46 (01) :38-66
[6]   Simultaneous Determination of Hydride and Non-Hydride Forming Elements by Inductively Coupled Plasma Optical Emission Spectrometry [J].
Benzo, Z. ;
Matos-Reyes, M. N. ;
Cervera, M. L. ;
de la Guardiaa, M. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (09) :1782-1787
[7]   Trace element levels in raw milk from northern and southern regions of Croatia [J].
Bilandzic, Nina ;
Dokic, Maja ;
Sedak, Marija ;
Solomun, Bozica ;
Varenina, Ivana ;
Knezevic, Zorka ;
Benic, Miroslav .
FOOD CHEMISTRY, 2011, 127 (01) :63-66
[8]  
Bonsak C. P., P ELMER LIFE ANAL SC
[9]  
Boss C.B., 2004, CONCEPTS INSTRUMENTA
[10]   A CRITICAL SURVEY OF HYDRIDE GENERATION TECHNIQUES IN ATOMIC SPECTROSCOPY [J].
CAMPBELL, AD .
PURE AND APPLIED CHEMISTRY, 1992, 64 (02) :227-244