Totally endoscopic robotic ventricular septal defect repair in the adult

被引:24
作者
Gao, Changqing [1 ]
Yang, Ming [1 ]
Wang, Gang [1 ]
Xiao, Cangsong [1 ]
Wang, Jiali [1 ]
Zhao, Yue [1 ]
机构
[1] Peoples Liberat Army Gen Hosp, Dept Cardiovasc Surg, Beijing 100853, Peoples R China
关键词
D O I
10.1016/j.jtcvs.2012.01.027
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We have previously reported total endoscopic ventricular septal defect repair in the adult using the da Vinci S Surgical System. The optimal results encouraged us to extend the use of this technology to more complicated patients with ventricular septal defect. Methods: From January 2009 to July 2010, 20 patients underwent total endoscopic robotic ventricular septal defect repair. The average patient age was 29.0 +/- 9.5 years (range, 16-45). Of the 20 patients, 9 were female and 11 were male. The echocardiogram demonstrated that the average diameter of the ventricular septal defect was 6.1 +/- 2.8 mm (range, 2-15), and 4 patients had concomitant patent foramen ovale. Ventricular septal defect closure was directly secured with interrupted mattress sutures in 14 patients and patched in 6 patients. All the procedures were completed using the da Vinci robot by way of 3 port incisions and a 2.0- to 2.5-cm working port in the right side of the chest. Results: All patients were operated on successfully. The mean cardiopulmonary bypass and mean crossclamp time was 94.3 +/- 26.3 minutes (range, 70-140) and 39.1 +/- 12.9 minutes (range, 22-75), respectively. The mean operation time was 225.0 +/- 34.8 minutes (range, 180-300). The postoperative transesophageal echocardiogram demonstrated an intact ventricular septum. No residual left-to-right shunting and no permanently complete atrioventricular dissociation was found postoperatively. The mean hospital stay was 5 days. No residual shunt was found during a mean follow-up of 7 months (range, 1-22). The patients returned to normal function within 1 week without any complications. Conclusions: Total endoscopic robotic ventricular septal defect repair in adult patients is feasible, safe, and efficacious. (J Thorac Cardiovasc Surg 2012; 144:1404-7)
引用
收藏
页码:1404 / 1407
页数:4
相关论文
共 50 条
  • [41] VENTRICULAR SEPTAL DEFECT IN ADULT AGE GROUP
    GRIFFITHS, SP
    BLUMENTHAL, S
    MORGAN, BC
    JAMESON, AG
    [J]. CIRCULATION, 1961, 24 (04) : 946 - &
  • [42] Intermediate-Term Outcomes of Totally Endoscopic Atrial Septal Defect Repair on Beating Heart in Small Children
    Nguyen, Uoc H.
    Dang, Huy Q.
    Nguyen, Huu C.
    Le, Thanh N.
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2022, 17 (03) : 223 - 230
  • [43] Totally endoscopic atrial septal defect repair using transthoracic aortic cannulation in a 10.5-kg-boy
    Dang, Huy Q.
    Le, Huong T.
    Ngo, Linh T. H.
    [J]. INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2018, 52 : 103 - 106
  • [44] VENTRICULAR SEPTAL DEFECT - SURVIVAL IN ADULT LIFE
    GRIFFITHS, SP
    BLUMENTHAL, S
    ELLIS, K
    JAMESON, AG
    MALM, JR
    MORGAN, BC
    [J]. AMERICAN JOURNAL OF MEDICINE, 1964, 37 (01) : 23 - &
  • [45] Totally endoscopic removal of dislocated atrial septal defect - closure devices
    Schachner, Thomas
    Grimm, Michael
    Bonaros, Nikolaos
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) : 1082 - 1082
  • [46] Transcatheter closure vs totally endoscopic robotic surgery for atrial septal defect closure: A single-center experience
    Kadirogullari, Ersin
    Onan, Burak
    Timur, Baris
    Birant, Ali
    Reyhancan, Adem
    Basgoze, Serdar
    Aydin, Unal
    [J]. JOURNAL OF CARDIAC SURGERY, 2020, 35 (04) : 764 - 771
  • [47] Totally Endoscopic Robotic Repair of Unroofed Coronary Sinus Syndrome
    Ishikawa, Norihiko
    Watanabe, Go
    Koakutsu, Toru
    Kato, Yuki
    Miyagi, Motomu
    Horikawa, Takafumi
    Tomita, Shigeyuki
    Ohtsuka, Toshiya
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2024, 19 (04) : 452 - 454
  • [48] Tricuspid Septal Leaflet Detachment for Ventricular Septal Defect Repair in Adults
    Roughneen, Patrick T.
    Conti, Vincent R.
    [J]. ANNALS OF THORACIC SURGERY, 2016, 102 (02) : E93 - E95
  • [49] Use of a Totally Artificial Heart for a Complex Postinfarction Ventricular Septal Defect
    Knezevic, Ivan
    Jelenc, Matija
    Danojevic, Nenad
    Racic, Manca
    Poglajen, Gregor
    Ksela, Jus
    Androcec, Vesna
    Mesar, Tomaz
    Mikuz, Ursa
    Vrtovec, Bojan
    [J]. HEART SURGERY FORUM, 2013, 16 (03) : E155 - E157
  • [50] Totally Endoscopic Atrial Septal Repair with or without Robotic Assistance: A Systematic Review and Meta-analysis of Case Series
    Yao, Dao-Kuo
    Chen, Hui
    Ma, Long-Le
    Ma, Zeng-Shan
    Wang, Le-Xin
    [J]. HEART LUNG AND CIRCULATION, 2013, 22 (06) : 433 - 440