Transcatheter closure of muscular ventricular septal defects with the Amplatzer ventricular septal defect occluder: Initial clinical applications in children

被引:99
作者
Thanopoulos, BD [1 ]
Tsaousis, GS [1 ]
Konstadopoulou, GN [1 ]
Zarayelyan, AG [1 ]
机构
[1] Aghia Sophia Childrens Hosp, Dept Pediat Cardiol, Athens 11527, Greece
关键词
D O I
10.1016/S0735-1097(99)00011-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to close muscular Ventricular septal defects (MVSDs) in children, with a new device, the Amplatzer ventricular septal defect occluder (AVSDO). BACKGROUND The design of previously used devices for transcatheter closure of MVSDs is not ideal for this purpose and their use has been limited by several drawbacks. METHODS Six patients, aged 3 to 10 years, with;MVSDs underwent transcatheter closure using the AVSDO. The device is a modified self-centering and repositionable Amplatzer device that consists of two low profile disks made of Nitinol wire mesh with a 7-mm connecting waist. The prosthesis size (connecting waist diameter) was chosen according to the measured balloon stretched VSD diameters. A 6-F or 7-F sheath was used for the delivery of the AVSDO. Fluoroscopy and transesophageal echocardiography were utilized for optimal guidance. RESULTS The location of the defect was midmuscular in five patients and beneath the pulmonary valve in one. The balloon stretched MVSD diameter ranged from 6 to 11 mm. Device placement was successful in all patients, and complete occlusion occurred in all six patients (95% confidence interval 54.06% to 100%). Two patients developed transient complete left bundle branch block. No other complications were observed. CONCLUSIONS This encouraging initial clinical success indicates that the AVSDO is a promising device for transcatheter closure of MVSDs in children. Further clinical trials and longer follow-up are needed before the widespread use of this technique can be recommended. CT Am Coil Cardiol (C) 1999 by the American College of Cardiology.
引用
收藏
页码:1395 / 1399
页数:5
相关论文
共 9 条
[1]   Closure of muscular ventricular septal defects with modified Amplatz device in a canine model [J].
Amin, Z ;
Gu, X ;
Berry, JM ;
Bass, JL ;
Urness, M ;
Titus, J ;
Amplatz, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :152A-153A
[2]   PREOPERATIVE TRANSCATHETER CLOSURE OF CONGENITAL MUSCULAR VENTRICULAR SEPTAL-DEFECTS [J].
BRIDGES, ND ;
PERRY, SB ;
KEANE, JF ;
GOLDSTEIN, SAN ;
MANDELL, V ;
MAYER, JE ;
JONAS, RA ;
CASTENEDA, AR ;
LOCK, JE .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (19) :1312-1317
[3]  
Kumar K, 1997, CIRCULATION, V95, P1207
[4]   TRANSCATHETER CLOSURE OF VENTRICULAR SEPTAL-DEFECTS [J].
LOCK, JE ;
BLOCK, PC ;
MCKAY, RG ;
BAIM, DS ;
KEANE, JF .
CIRCULATION, 1988, 78 (02) :361-368
[5]  
Mavroudis C, 1994, PEDIAT CARDIAC SURG, P201
[6]   Transvenous closure of secundum atrial septal defects - Preliminary results with a new self-expanding nitinol prosthesis in a swine model [J].
Sharafuddin, MJA ;
Gu, XP ;
Titus, JL ;
Urness, M ;
CerveraCeballos, JJ ;
Amplatz, K .
CIRCULATION, 1997, 95 (08) :2162-2168
[7]   Occlusion of congenital ventricular septal defects by the buttoned device [J].
Sideris, EB ;
Walsh, KP ;
Haddad, JL ;
Chen, CR ;
Ren, SG ;
Kulkarni, H .
HEART, 1997, 77 (03) :276-279
[8]   Closure of atrial septal defects with the amplatzer occlusion device: Preliminary results [J].
Thanopoulos, BD ;
Laskari, CV ;
Tsaousis, GS ;
Zarayelyan, A ;
Vekiou, A ;
Papadopoulos, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (05) :1110-1116
[9]   TRANSESOPHAGEAL ECHOCARDIOGRAPHIC GUIDANCE OF TRANSCATHETER VENTRICULAR SEPTAL-DEFECT CLOSURE [J].
VANDERVELDE, ME ;
SANDERS, SP ;
KEANE, JF ;
PERRY, SB ;
LOCK, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) :1660-1665