Effects of the geothermal load on the ground temperature recovery in a ground heat exchanger

被引:29
作者
Baek, Seung Hyo [1 ]
Yeo, Myoung Souk [2 ]
Kim, Kwang Woo [2 ]
机构
[1] Seoul Natl Univ, Grad Sch, Dept Architecture & Architectural Engn, 1 Gwanak Ro, Seoul 08826, South Korea
[2] Seoul Natl Univ, Coll Engn, Dept Architecture & Architectural Engn, 1 Gwanak Ro, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
Ground coupled heat pump; Ground temperature recovery; Ground heat exchanger; Geothermal load; Recovery time; Soil thermal conductivity; Geothermal load pattern; PUMP SYSTEM; DESIGN; PERFORMANCE; VALIDATION; RESISTANCE; MODEL;
D O I
10.1016/j.enbuild.2016.11.056
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of the geothermal load on the ground temperature recovery in a ground heat exchanger (GHE) were investigated. A three-dimensional equivalent transient GHE analysis model was developed and validated against measured thermal response test (TRT) data and sandbox reference dataset. The effects of amount of geothermal load, duration of the recovery time per day, and daily geothermal load pattern on the ground temperature recovery were examined. The results showed that decreasing the amount of geothermal load and increasing the recovery time can improve the ground temperature recovery. However, there is little correlation between the daily geothermal load pattern and ground temperature recovery. The effects of the geothermal load on ground temperature recovery were also analyzed under different soil thermal conductivity conditions. The duration of the recovery time significantly influences the ground temperature recovery at low soil thermal conductivity. These results demonstrate the importance of considering the recovery time in the GHEs design stage to reduce the borehole length. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 30 条
[1]  
American Society of Heating Refrigerating and Air-Conditioning Engineers, 2011, ATLANTA, V2011
[2]   Transient 3D analysis of borehole heat exchanger modeling [J].
Bauer, D. ;
Heidemann, W. ;
Diersch, H. -J. G. .
GEOTHERMICS, 2011, 40 (04) :250-260
[3]  
Bauer D., 2007, INT J ENERG RES, V35, P312
[4]   Reference data sets for vertical borehole ground heat exchanger models and thermal response test analysis [J].
Beier, Richard A. ;
Smith, Marvin D. ;
Spitler, Jeffrey D. .
GEOTHERMICS, 2011, 40 (01) :79-85
[5]  
Bernier MA, 2008, ASHRAE TRAN, V114, P342
[6]   Restoration performance of vertical ground heat exchanger with various intermittent ratios [J].
Cao Xiaoling ;
Yuan Yanping ;
Sun Liangliang ;
Lei Bo ;
Yu Nanyang ;
Yang Xiaojiao .
GEOTHERMICS, 2015, 54 :115-121
[7]   Borehole latent energy storage system integrated with solar thermal collectors and heat pumps [J].
Nejad, Parham Eslami ;
Bastani, Arash ;
Nguyen, Alain ;
Saloux, Etienne .
PROCEEDINGS OF BUILDING SIMULATION 2021: 17TH CONFERENCE OF IBPSA, 2022, 17 :207-214
[8]   The quantitative evaluation of design parameter's effects on a ground source heat pump system [J].
Cho, Honghyun ;
Choi, Jong Min .
RENEWABLE ENERGY, 2014, 65 :2-6
[9]  
Choi M., 2011, P BUILD SIM 2011 12, P1556
[10]   Numerical analysis and experimental validation of heat transfer in ground heat exchangers in alternative operation modes [J].
Cui, P. ;
Yang, H. ;
Fang, Z. .
ENERGY AND BUILDINGS, 2008, 40 (06) :1060-1066