Voltage harmonic distortion at buses feeding office loads

被引:0
作者
Demoulias, Charis [1 ]
Goutzamanis, Dimitris [2 ,3 ]
Gouramanis, Kostas [2 ]
机构
[1] Aristotle Univ Thessaloniki, Elect Machines Lab, Dept Elect & Comp Engn, Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Thessaloniki, Greece
[3] Alteren SA, Thessaloniki, Greece
来源
2007 IEEE LAUSANNE POWERTECH, VOLS 1-5 | 2007年
关键词
harmonics; voltage harmonic distortion; cable impedance; cable configuration;
D O I
10.1109/PCT.2007.4538545
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The total harmonic distortion of the phase-to-neutral voltage at buses feeding office load is investigated for various cable configurations, lengths and cross-sections. The investigation is carried out with a software model which was validated with approximate analytical expressions and measurements taken at a real installation. It is shown that the selection of a cable should based not only on its ampacity and allowable voltage drop but its configuration should be taken into account in order to avoid excessive voltage harmonic distortion. Configurations where the neutral conductor is part of a four-core cable cause relatively small harmonic distortion while cable configurations where the neutral conductor runs separately cause high voltage harmonic distortion.
引用
收藏
页码:1546 / +
页数:2
相关论文
共 50 条
  • [41] Voltage and current distortion generated by the CNC
    Bartman, Jacek
    Palczak, Arkadiusz
    [J]. 2017 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2017,
  • [42] Parameter estimation of harmonic polluting industrial loads
    Maza-Ortega, JM
    Gómez-Expósito, A
    Trigo-García, JL
    Burgos-Payán, M
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (9-10) : 635 - 640
  • [43] Recursive identification of harmonic loads in power systems
    AL-Kandari, Ahmed M.
    El-Naggar, Khaled M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2006, 28 (08) : 531 - 536
  • [44] Parameter estimation of harmonic polluting industrial loads
    Maza-Ortega, JA
    Gómez-Expósito, A
    Trigo-García, JL
    Burgos-Payán, A
    [J]. 2004 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, 2004, : 199 - 204
  • [45] Harmonic Filtering in PV connected AC loads
    UlHaq, Ehtasham
    Ali, Jawad
    Jan, Waleed
    Aman, Muhammad Aamir
    Munir, Mehr E.
    [J]. JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES, 2019, 14 (04): : 571 - 575
  • [46] Restraint method of voltage total harmonic distortion in distribution network by power conditioner systems using measured data from IT switches
    Kawasaki, Shoji
    Shimoda, Kazuki
    Tanaka, Motohiro
    Taoka, Hisao
    Matsuki, Junya
    Hayashi, Yasuhiro
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 2013, 182 (03) : 19 - 29
  • [47] Restraint method of voltage total harmonic distortion in distribution network by power conditioner systems using measured data from IT switches
    Kawasaki S.
    Shimoda K.
    Tanaka M.
    Taoka H.
    Matsuki J.
    Hayashi Y.
    [J]. IEEJ Transactions on Power and Energy, 2011, 131 (12) : 936 - 944
  • [48] Identification of Harmonic Injection and Distortion Power at Customer Location
    Anu, G.
    Fernandez, Francis M.
    [J]. 2020 19TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2020,
  • [49] A Comparative Analysis of Total Harmonic Distortion in TPRD and RNSIC
    Filote, C.
    Ciuffudean, C.
    Cozgarea, A. M.
    [J]. EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 5808 - 5815
  • [50] Harmonic distortion in a modern cement industry - A case study
    Kumar, V. Suresh
    Kannan, P. S.
    Saravanan, V.
    [J]. 2006 IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2006, : 760 - +