MASK LEAKAGE IN CONTINUOUS POSITIVE AIRWAY PRESSURE AND C-FLEX

被引:0
作者
Leidag, M. [1 ]
Hader, C. [1 ]
Keller, T. [1 ]
Meyer, Y. [1 ]
Rasche, K. [1 ]
机构
[1] Univ Dusseldorf, Akad Lehrkrankenhaus, Klin Pneumol Allergol Schlaf & Beatmungsmed, Kliniken St Antonius,Lungenzentrum, D-42109 Wuppertal, Germany
来源
JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY | 2008年 / 59卷
关键词
C-Flex; compliance; continuous positive airway pressure; mask leakage; obstructive sleep apnea syndrome;
D O I
暂无
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Many patients with obstructive sleep apnea syndrome (OSAS) receiving continuous positive airway pressure (CPAP) complain of leaky masks or too high pressure during expiration. C-Flex is a breathing mode with a constant CPAP pressure during inspiration and a reduced pressure during expiration. We compared the leakage data between CPAP and C-Flex and their influence on patients' compliance. Thirty patients (22 men, 8 women, aged 55.4 +/- 11.7 yr, BMI 32.0 +/- 7.4 kg/m(2)) with polysomnographically diagnosed OSAS got a CPAP or C-Flex therapy in a randomized double-blind and cross-over design. After 6 weeks, an adjustment to the other mode followed. Leakage data were sampled during all polysomnographic examinations. Twelve patients dropped out of the study (7 after C-Flex, 5 after CPAP), 4 of them gave up CPAP therapy completely (2 after CPAP, 2 after C-Flex). The leakage in CPAP mode was 27.5 +/- 11.5 l/min and in C-Flex mode 28.0 +/- 10 l/min (ns). The average nightly use in CPAP mode was 350.0 +/- 70.2 min and in C-Flex mode 347.0 +/- 70.8 min (ns). In the final decision of therapy, 9 patients chose C-Flex and 4 patients CPAP (P=0.001). Five patients had no preference regarding the therapy mode. There is no difference in leakage and compliance between CPAP and C-Flex. But significantly more patients decided for a therapy with the C-Flex mode. There must be other unknown factors that influence the decision for the mode of therapy.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 17 条
[1]   Treatment adherence and outcomes in flexible vs standard continuous positive airway pressure therapy [J].
Aloia, MS ;
Stanchina, M ;
Arnedt, JT ;
Malhotra, A ;
Millman, RP .
CHEST, 2005, 127 (06) :2085-2093
[2]  
Duntley S, 2005, SLEEP, V28, pA182
[3]   Self-reported use of CPAP and benefits of CPAP therapy - A patient survey [J].
Engleman, HM ;
AsgariJirhandeh, N ;
McLeod, AL ;
Ramsay, CF ;
Deary, IJ ;
Douglas, NJ .
CHEST, 1996, 109 (06) :1470-1476
[4]   Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research [J].
Flemons, WW ;
Buysse, D ;
Redline, S ;
Pack, A ;
Strohl, K ;
Wheatley, J ;
Young, T ;
Douglas, N ;
Levy, P ;
McNicholas, W ;
Fleetham, J ;
White, D ;
Schmidt-Nowarra, W ;
Carley, D ;
Romaniuk, J .
SLEEP, 1999, 22 (05) :667-689
[5]  
Hein H, 2001, Pneumologie, V55, P339, DOI 10.1055/s-2001-15613
[6]   Can intensive support improve continuous positive airway pressure use in patients with the sleep apnea/hypopnea syndrome? [J].
Hoy, CJ ;
Vennelle, M ;
Kingshott, RN ;
Engleman, HM ;
Douglas, NJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (04) :1096-1100
[7]  
Keller T, 2007, J PHYSIOL PHARMACOL, V58, P313
[8]   Predictive factors of quality-of-life improvement and continuous positive airway pressure use in patients with sleep apnea-hypopnea syndrome -: Study at 1 year [J].
Lloberes, P ;
Martí, S ;
Sampol, G ;
Roca, A ;
Sagales, T ;
Muñoz, X ;
Ferrer, M .
CHEST, 2004, 126 (04) :1241-1247
[9]  
MOHAN K, 2004, SLEEP S494, V494, pA221
[10]   Pressure-relief continuous positive airway pressure vs constant continuous positive airway pressure - A comparison of efficacy and compliance [J].
Nilius, Georg ;
Happel, Andreas ;
Domanski, Ulrike ;
Ruhle, Karl-Heinz .
CHEST, 2006, 130 (04) :1018-1024