Intraoperative Evaluation of the HeartMate II Flow Estimator

被引:47
作者
Slaughter, Mark S. [1 ]
Bartoli, Carlo R. [3 ,4 ]
Sobieski, Mike A. [6 ]
Pantalos, George M.
Giridharan, Guruprasad A. [2 ]
Dowling, Robert D.
Prabhu, Sumanth D. [3 ]
Farrar, David J. [5 ]
Koenig, Steven C. [2 ]
机构
[1] Univ Louisville, Div Cardiothorac Surg, Dept Surg, Cardiovasc Innovat Inst, Louisville, KY 40202 USA
[2] Univ Louisville, Dept Bioengn, Cardiovasc Innovat Inst, Louisville, KY 40202 USA
[3] Univ Louisville, Inst Mol Cardiol, Dept Med, Louisville, KY 40202 USA
[4] Univ Louisville, Sch Med, Louisville, KY 40202 USA
[5] Thoratec Corp, Pleasanton, CA USA
[6] Advocate Christ Med Ctr, Oak Lawn, IL USA
关键词
ROTARY BLOOD PUMPS; VENTRICULAR-ARRHYTHMIAS; CONTROL-SYSTEM; EXPERIENCE;
D O I
10.1016/j.healun.2008.10.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Direct measurement of blood flow output has been incorporated into ventricular assist devices (VADs), but long-term reliability of the additional device components has raised concerns regarding sensor drift and failure. As :in alternative approach, the HeartMate II axial VAD (Thoratec Corp, Pleasanton, CA) estimates device flow output from power consumption and rotational speed of the device motor. This study evaluated the accuracy of HeartMate II flow estimation at the time of implantation. Methods: In 20 patients, intraoperative blood flow measurement of the HeartMate 11 flow estimator was compared with flow values obtained with an ultrasonic flow probe placed around the device outflow graft. Estimated and measured VAD flow data were simultaneously recorded and digitally stored while the device motor speed varied from 7,800 to 11,000 rpm and while achieving device flow outputs of 2 to 7 liters/min. Estimated and measured flows were compared using linear regression analyses and root mean square error. Results: HeartMate 11 flow estimation (FE) demonstrated a linear correlation with ultrasonic flow probe (FP) measurements: FE = 0.74 FP + 0.99 (R-2 = 0.56, p = 0.0001). A root mean square error of 0.8 liters/min was observed between flow estimation and direct flow measurement and suggests a 15% to 20% difference at flows of 4 of 6 liters/min. Conclusions: These results suggest that HeartMate II flow estimation may be used to provide directional information for trend purposes rather than absolute values of device blood flow output. Patient management should include but not be limited to this information. J Heart Lung Transplant 2009; 28:39-43. Copyright (C) 2009 by the International Society for Heart and Lung Transplantation.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 17 条
[1]   Off-pump exchange of short-term percutaneous ventricular assist device (VAD) to long-term implantable VAD in severe coagulopathy and multi-organ failure [J].
Busch, Jonas ;
Wojciechowski, Zbiguiew ;
Torre-Amione, Guillermo ;
Loebe, Matthias .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (05) :572-574
[2]  
Drew G., 2002, Virtual Bio-Instrumentation: Biomedical, Clinical, and Healthcare Applications in LabVIEW, P180
[3]   Design features, developmental status, and experimental results with the heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor [J].
Farrar, David J. ;
Bourque, Kevin ;
Dague, Charles P. ;
Cotter, Christopher J. ;
Poirier, Victor L. .
ASAIO JOURNAL, 2007, 53 (03) :310-315
[4]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[5]   In vitro evaluation of multiobjective hemodynamic control of a heart-assist pump [J].
Gwak, KW ;
Ricci, M ;
Snyder, S ;
Paden, BE ;
Boston, JR ;
Simaan, MA ;
Antaki, JF .
ASAIO JOURNAL, 2005, 51 (04) :329-335
[6]   BIOCHEMICAL AND STRUCTURAL CORRELATES IN UNLOADED AND RELOADED CAT MYOCARDIUM [J].
KENT, RL ;
UBOH, CE ;
THOMPSON, EW ;
GORDON, SS ;
MARINO, TA ;
HOOBER, JK ;
COOPER, G .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1985, 17 (02) :153-165
[7]  
Kinoshita M, 1988, ASAIO Trans, V34, P208
[8]   Influence of prolonged ventricular assistance on myocardial histopathology in intact heart [J].
Kinoshita, M ;
Takano, H ;
Takaichi, S ;
Taenaka, Y ;
Nakatani, T .
ANNALS OF THORACIC SURGERY, 1996, 61 (02) :640-645
[9]  
Koenig Steven C., 2004, Biomedical Instrumentation & Technology, V38, P229
[10]   Noninvasive average flow estimation for an implantable rotary blood pump: A new algorithm incorporating the role of blood viscosity [J].
Malagutti, Nicolo ;
Karantonis, Dean M. ;
Cloherty, Shaun L. ;
Ayre, Peter J. ;
Mason, David G. ;
Salamonsen, Robert F. ;
Lovell, Nigel H. .
ARTIFICIAL ORGANS, 2007, 31 (01) :45-52