Development of a transportable neutron activation analysis system to quantify manganese in bone in vivo: feasibility and methodology

被引:27
作者
Liu, Yingzi [1 ]
Koltick, David [2 ]
Byrne, Patrick [1 ,3 ]
Wang, Haoyu [2 ]
Zheng, Wei [1 ]
Nie, Linda H. [1 ]
机构
[1] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Phys, W Lafayette, IN 47907 USA
[3] Med Phys Consultants Inc, Indianapolis, IN USA
关键词
IVNAA; DD neutron generator; Mn; hand bone; EXPOSURE; TRICARBONYL; BIOMARKERS; SMELTERS; ALUMINUM; CHLORIDE; CADMIUM;
D O I
10.1088/0967-3334/34/12/1593
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study was conducted to investigate the methodology and feasibility of developing a transportable neutron activation analysis (NAA) system to quantify manganese (Mn) in bone using a portable deuterium-deuterium (DD) neutron generator as the neutron source. Since a DD neutron generator was not available in our laboratory, a deuterium-tritium (DT) neutron generator was used to obtain experimental data and validate the results from Monte Carlo (MC) simulations. After validation, MC simulations using a DD generator as the neutron source were then conducted. Different types of moderators and reflectors were simulated, and the optimal thicknesses for the moderator and reflector were determined. To estimate the detection limit (DL) of the system, and to observe the interference of the magnesium (Mg) gamma line at 844 keV to the Mn gamma line at 847 keV, three hand phantoms with Mn concentrations of 30 parts per million (ppm), 150 ppm, and 500 ppm were made and irradiated by the DT generator system. The Mn signals in these phantoms were then measured using a 50% high-efficiency high-purity germanium (HPGe) detector. The DL was calculated to be about 4.4 ppm for the chosen irradiation, decay, and measurement time. This was calculated to be equivalent to a DL of about 3.3 ppm for the DD generator system. To achieve this DL with one 50% high-efficiency HPGe detector, the dose to the hand was simulated to be about 37 mSv, with the total body equivalent dose being about 23 mu Sv. In conclusion, it is feasible to develop a transportable NAA system to quantify Mn in bone in vivo with an acceptable radiation exposure to the subject.
引用
收藏
页码:1593 / 1609
页数:17
相关论文
共 44 条
  • [1] Andersen ME, 1999, NEUROTOXICOLOGY, V20, P161
  • [2] Opportunities to improve the in vivo measurement of manganese in human hands
    Aslam
    Chettle, D. R.
    Pejovic-Milic, A.
    Waker, A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) : 17 - 28
  • [3] Noninvasive measurement of aluminium in human bone: Preliminary human study and improved system performance
    Aslam
    Davis, K.
    Pejovic-Milic, A.
    Chettle, D. R.
    [J]. JOURNAL OF INORGANIC BIOCHEMISTRY, 2009, 103 (11) : 1585 - 1590
  • [4] Aslam, 2008, PHYS MED BIOL, V53, P4081, DOI [10.1088/0031-9155/53/15/005, 10.1088/0031-9155/53/19/N02]
  • [5] Intellectual Impairment in School-Age Children Exposed to Manganese from Drinking Water
    Bouchard, Maryse F.
    Sauve, Sebastien
    Barbeau, Benoit
    Legrand, Melissa
    Brodeur, Marie-Eve
    Bouffard, Therese
    Limoges, Elyse
    Bellinger, David C.
    Mergler, Donna
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2011, 119 (01) : 138 - 143
  • [6] Role of manganese in neurodegenerative diseases
    Bowman, Aaron B.
    Kwakye, Gunnar F.
    Hernandez, Elena Herrero
    Aschner, Michael
    [J]. JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2011, 25 (04) : 191 - 203
  • [7] Speciation of methylcyclopentadienyl manganese tricarbonyl and its derivatives: A review
    Butcher, DJ
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2002, 37 (01) : 1 - 17
  • [8] Improvement ofin vivoneutron activation analysis of Mn using a 4π NaI(Tl) detector array
    Byun, S. H.
    Pejovic-Milic, A.
    Prestwich, W. V.
    Chettle, D. R.
    McNeill, F. E.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (03) : 615 - 618
  • [9] Chetri K, 2003, Indian J Gastroenterol, V22 Suppl 2, pS28
  • [10] TECHNIQUES OF INVIVO NEUTRON-ACTIVATION ANALYSIS
    CHETTLE, DR
    FREMLIN, JH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (09) : 1011 - 1043